SSV IGW/925-W Application guide

Remote Access Gateway IGW/925-
W
with DIL/NetPC ADNP/9200
Hardware Reference
SSV Embedded Systems
Dünenweg 5
D-30419 Hannover
Phone: +49 (0)511/40 000-0
Fax: +49 (0)511/40 000-40
E-mail: sales@ssv-embedded.de
Document Revision: 1.1
Date: 2015-08-26
FOR FURTHER INFORMATION REGARDING OUR PRODUCTS PLEASE VISIT US AT WWW.SSV-EMBEDDED.DE

Remote Access Gateway IGW/925-W – Hardware Reference
2
D oc u me nt R e vi s io n 1 .1
CONTENT
1 INTRODUCTION...............................................................................................................3
1.1 Safety Guidelines.................................................................................................................3
1.2 Conventions .........................................................................................................................3
1.3 Features and Technical Data................................................................................................4
1.4 Main Applications ...............................................................................................................5
1.5 Demo Applications ..............................................................................................................5
2 OVERVIEW .......................................................................................................................6
3 CONNECTIONS................................................................................................................7
3.1 Ethernet LAN 1A – D..........................................................................................................7
3.2 Ethernet LAN 2....................................................................................................................7
3.3 Serial Port COM1 ................................................................................................................8
3.4 Serial Port COM2 ................................................................................................................9
3.5 Power Supply.....................................................................................................................10
3.6 Semiconductor Relay Output.............................................................................................11
4 HELPFUL LITERATURE ................................................................................................12
CONTACT .............................................................................................................................12
DOCUMENT HISTORY .........................................................................................................12

Remote Access Gateway IGW/925-W – Hardware Reference
D oc u me n t R e vi s i o n 1. 1
3
1 INTRODUCTION
This document describes the hardware components and the necessary cable connections of
the Remote Access Gateway IGW/925-W.
1.1 Safety Guidelines
Please read the following safety guidelines carefully! In case of property or personal
damage by not paying attention to this document and/or by incorrect handling, we do
not assume liability. In such cases any warranty claim expires.
ATTENTION: Observe precautions for handling – electrostatic sensitive device!
•Discharge yourself before you work with the device, e.g. by touching a heater of
metal, to avoid damages.
•Stay grounded while working with the device to avoid damage through electrostatic
discharge.
1.2 Conventions
Convention
Usage
bold Important terms
italic Filenames, user inputs and command lines
monospace Pathnames, internet addresses and program code
Table 1: Conventions used in this document

Remote Access Gateway IGW/925-W – Hardware Reference
4
D oc u me n t R e vi s i o n 1. 1
1.3 Features and Technical Data
Processor
Manufacturer / Type
Atmel AT91RM9200 32-bit ARM9-MCU
(DIL/NetPC ADNP/9200 on QIL-128 socket)
Clock speed
180 MHz
Memory
RAM
64 MB SDRAM
Flash
32 MB NOR memory
Storage media
1x internal microSD card holder with 4 GB card
(preconfigured
with SQLite database)
Interfaces
Ethernet
1x 10/100 Mbps (RJ45)
4x 10/100 Mbps (RJ-45) over integrated 4-port switch
with Auto MDI-X support
Serial I/Os
1x RS232 serial port with handshake (Sub-D)
1x RS232/RS485 serial port with software-
selectable mode
switch (screw terminal)
Alarm output
1x Semiconductor relay output (max. 30 VDC, 500 mA)
Special Functions
RTC
1x Real Time Clock with battery-backup (CR1225 Lithium 3 V)
Watchdog
1x Timer watchdog (hardware-based, software-configurable)
1x Power supervisor (hardware-based)
Wireless Module
WiFi standards
IEEE 802.11 b/g/n (2.4 GHz)
Network protocols
TCP/IP, UDP/IP
Operating modes
Simultaneous Soft AP
Client mode with DHCP server
Security
IEEE 802.11i support with WPA/WPA2
256-bit AES encryption
Management
Web server with landing page and WebUI
Displays / Control Elements
LEDs
1x Power
1x IGW start-up + VPN status (programmable)
1x LAN LED for Ethernet interface LAN 1A - D
2x LAN LED for Ethernet interface LAN 2
Electrical Characteristics
Power supply
12 .. 24 VDC (typ. 24 VDC) from external power supply
Power consumption
< 4 W
Mechanical Characteristics
Protection class
IP20 industrial case for 35 mm DIN-rail mounting
Mass
< 270 g
Dimensions
112 mm x 100 mm x 45 mm
Operating temperature
0 .. 70 °C
Standards and Certifications
EMC
CE
Environmental
standards
RoHS, WEEE
Industrial standards
VHPready (Virtual Heat & Power Ready)

Remote Access Gateway IGW/925-W – Hardware Reference
D oc u me n t R e vi s i o n 1. 1
5
1.4 Main Applications
•Remote Access Security Gateway
•Industrial Firewall
•Application Gateway
•Proxy Server
•VPN Gateway / Router
•Linux Device Server
1.5 Demo Applications
•Smartphone App Backend
•Data logger with cloud connection

Remote Access Gateway IGW/925-W - Hardware Reference
6
D oc u me n t R e vi s i o n 1. 1
2 OVERVIEW
Figure 1: Overview Remote Access Gateway IGW/925-W

Remote Access Gateway IGW/925-W – Hardware Reference
D oc u me n t R e vi s i o n 1. 1
7
3 CONNECTIONS
3.1 Ethernet LAN 1A – D
The Ethernet interfaces LAN 1A – D offer each a green LED. It is on when there is a LAN
link established and blinks when there is traffic. The yellow LED is not connected.
The Ethernet interfaces LAN 1A – D are equal. They are connected over an integrated 4-port
switch.
The Ethernet interfaces LAN 1A – D support Auto MDI/MDIX.
Pin
Name
Fu
nction
1
TX+ 10/100 Mbps LAN, TX+ Pin
2
TX- 10/100 Mbps LAN, TX- Pin
3
RX+ 10/100 Mbps LAN, RX+ Pin
4
--- Not Connected
5
--- Not Connected
6
RX- 10/100 Mbps LAN, RX- Pin
7
--- Not Connected
8
--- Not Connected
Table 2: Pinout Ethernet interfaces LAN 1A – D
3.2 Ethernet LAN 2
The Ethernet LAN 2 interface offers a green LED. It is on when there is a LAN link estab-
lished and blinks when there is traffic. The yellow LED is not connected.
The Ethernet interface LAN 2 does NOT support Auto MDI/MDIX.
Pin
Name
Fu
nction
1
TX+ 10/100 Mbps LAN, TX+ Pin
2
TX- 10/100 Mbps LAN, TX- Pin
3
RX+ 10/100 Mbps LAN, RX+ Pin
4
--- Not Connected
5
--- Not Connected
6
RX- 10/100 Mbps LAN, RX- Pin
7
--- Not Connected
8
--- Not Connected
Table 3: Pinout Ethernet interface LAN 2

Remote Access Gateway IGW/925-W – Hardware Reference
8
D oc u me n t R e vi s i o n 1. 1
3.3 Serial Port COM1
The serial port COM1 is a standard Sub-D connector.
Pin
Name
Function
1
DCD COM1 Serial Port, DCD pin (RS232)
2
RXD COM1 Serial Port, RXD pin (RS232)
3
TXD COM1 Serial Port, TXD pin (RS232)
4
DTR COM1 Serial Port, DTR pin (RS232)
5
GND Ground
6
DSR COM1 Serial Port, DSR pin (RS232)
7
RTS COM1 Serial Port, RTS pin (RS232)
8
CTS COM1 Serial Port, CTS pin (RS232)
9
DCD COM1 Serial Port, DCD pin (RS232)
Table 4: Pinout COM1 connector

Remote Access Gateway IGW/925-W – Hardware Reference
D oc u me n t R e vi s i o n 1. 1
9
3.4 Serial Port COM2
To create an RS232 serial link on port COM2 of the Remote Access Gateway IGW/925-W
connect the adapter cable and the null-modem cable like shown in the figure below.
Figure 2: RS232 link on serial port COM2
Terminal
Signal
B2
COM2 Serial Port: TXD (RS232), RX/TX- (RS485)
B3
COM2 Serial Port: RXD (RS232), RX/TX+ (RS485)
B4
Ground
Table 5: Screw terminal COM2

Remote Access Gateway IGW/925-W – Hardware Reference
10
D oc u me n t R e vi s i o n 1. 1
3.5 Power Supply
The Remote Access Gateway IGW/925-W needs a supply voltage of 11 .. 28 VDC to work.
Use the power adapter cable to provide the system with the necessary power like shown in
the figure below.
Figure 3: Power supply for the Remote Access Gateway IGW/925-W
Terminal
Signal
A3
Vin (11 .. 28 VDC)
A4
GNDin
Table 6: Screw terminal power
CAUTION!
Providing the Remote Access Gateway IGW/925-W with a higher voltage than the regular
11 .. 28 VDC ±10 % could cause damaged board components!
CAUTION!
Do NOT turn on the power supply while connecting the power adapter cable with the
Remote Access Gateway IGW/925-W. This could cause damaged board components! First
connect the power adapter cable and THEN turn the power supply on.

Remote Access Gateway IGW/925-W – Hardware Reference
D oc u me n t R e vi s i o n 1. 1
11
3.6 Semiconductor Relay Output
The Remote Access Gateway IGW/925-W offers a semiconductor relay output to switch an
external alarm device with up to 30 VDC and 500 mA on and off.
Figure 4: Connecting an external alarm device
Terminal
Signal
A1
Alarm- Semiconductor Relay Output (max. 30 VDC / 500 mA)
A2
Alarm+ Semiconductor Relay Output (max. 30 VDC / 500 mA)
Table 7: Screw terminal semiconductor relay output
CAUTION!
Using the alarm output with more than the regular 30 VDC and 500 mA could cause dam-
aged board components!

Remote Access Gateway IGW/925-W – Hardware Reference
12
D oc u me n t R e vi s i o n 1. 1
4 HELPFUL LITERATURE
•IGW/92X-W first steps
•E2W/ESL2 hardware reference
•DIL/NetPC ADNP/9200 hardware reference
CONTACT
SSV Embedded Systems
Dünenweg 5
D-30419 Hannover
Phone: +49 (0)511/40 000-0
Fax: +49 (0)511/40 000-40
Internet: www.ssv-embedded.de
Forum: www.ssv-comm.de/forum
DOCUMENT HISTORY
Revision
Date
Remarks
Name
Review
1.0 2014-09-24 First version WBU ENE
1.1 2015-08-26 edited chapter 1.3 WBU ENE
The content of this document can change any time without an
nouncement. There is taken over no guarantee
for the accuracy of the statements. The user assumes the en
tire risk as to the accuracy and the use of this doc-
ument. Information in this document is provided ‘as is’ without warra
nty of any kind. Some names within this
document can be trademarks of their respective holders.
© 2015 SSV EMBEDDED SYSTEMS. All rights reserved.
Table of contents
Other SSV Gateway manuals

SSV
SSV IGW/910 Application guide

SSV
SSV RMG/941L User manual

SSV
SSV IGW/922 User manual

SSV
SSV IGW/920 User manual

SSV
SSV IGW/935 Application guide

SSV
SSV IGW/936A User guide

SSV
SSV IGW/935 User manual

SSV
SSV IGW/941 Application guide

SSV
SSV IGW/925 Installation and user guide

SSV
SSV IGW/922 Application guide