Remote Access Gateway IGW/941 – Hardware Reference
2
D oc u m e n t R e v i s i o n 1 . 4
CONTENT
1
INTRODUCTION ............................................................................................................... 3
1.1
Safety Guidelines ................................................................................................................... 3
1.2
Conventions ........................................................................................................................... 3
1.3
Features and Technical Data ................................................................................................. 4
2
OVERVIEW ....................................................................................................................... 5
3
INOUTS .......................................................................................................................... 6
3.1
Ethernet Interface .................................................................................................................. 6
3.2
Scre Terminals ..................................................................................................................... 6
3.3
Service Port ............................................................................................................................ 7
4
SIM CARD ......................................................................................................................... 8
5
HEL FUL LITERATURE .................................................................................................. 9
CONTACT ............................................................................................................................... 9
DOCUMENT HISTORY ........................................................................................................... 9

Remote Access Gateway IGW/941 – Hardware Reference
D o c u m e n t R e v i s i o n 1 . 4
3
1 INTRODUCTION
This document describes the hardware components and the necessary cable connections of
the Remote Access Gateway IGW/941.
1.1 Safety Guidelines
Please read the following safety guidelines carefully! In case of property or personal
damage by not paying attention to this manual and/or by incorrect handling, we do not
assume liability. In such cases any warranty claim expires.
• The power supply should be in immediate pro imity to the device.
• The power supply must provide a stable output voltage at 24 VDC ± 10%. The out-
put power should be at least 10 W.
• Please pay attention that the power cord or other cables are not squeezed or dam-
aged in any way when you set up the device.
• Do NOT turn on the power supply while connecting any cables, especially the pow-
er cables. This could cause damaged device components! First connect the cables
and THEN turn the power supply on.
• The installation of the device should be done only by qualified personnel.
• Discharge yourself electrostatic before you work with the device, e.g. by touching a
heater of metal, to avoid damages.
• Stay grounded while working with the device to avoid damage through electrostat-
ic discharge.
• The case of the device should be opened only by qualified personnel.
1.2 Conventions
Convention
Usage
bold
Important terms and information
monospac
e
Filenames, Pathnames, program code, command lines
Table 1: onventions used in this document

Remote Access Gateway IGW/941 – Hardware Reference
4
D o c u m e n t R e v i s i o n 1 . 4
1.3 Features and Technical Data
Processor
Manufacturer / Type
Atmel ATSAM
-
A5D35
SoC
lock speed
528
MHz
emory
RAM
256
MB SDRAM
Flash
4
MB NOR memory
Storage media
1 internal microSD card holder
Interfaces
Ethernet
1 10/100 Mbps (RJ45)
Serial I/Os
1 RS485 serial port (screw terminal)
OM (
Service
Port)
1 6
-
pin connector
Antenna
1 SMA
male
connector for LTE antenna
Special Functions
Watchdog
1 Timer watch
dog (hardware
-
based, software
-
configurable)
1 Power supervisor (hardware-based)
SIM card
1 Mini
-
SIM card holder (accessible from the outside)
Wireless odule
Mobile radio standards
GSM/UMTS/HSPA+/LTE
Transfer rates
15
0 Mbps peak download, 50 Mbps pea
k upload
Frequency bands
LTE:
2600 MHz (B7), 2100 MHz (B1), 1800 MHz (B3),
900 MHz (B8), 850 MHz (B5), 800 MHz (B20)
W DMA: 2100 MHz (B1), 850 MHz (B5), 900 MHz (B8)
GSM/GPRS: Quad-band 850/900/1800/1900 MHz
Authentication
PAP, CHAP, CHAT, none
Supporte
d APNs
Telekom, Vodafone, 02, E
-
Plus, user
-
defined
Displays / Control Elements
LEDs
1 Power
1 System status (programmable)
2 LAN LED for Ethernet interface
Electrical Characteristics
Power supply
range
12 .. 2
7
VDC from e ternal power supply
Power
consumption
<
1
5
W
echanical Characteristics
Protection class
IP20 industrial case for 35 mm DIN
-
rail mounting
Mass
< 150 g
Dimensions
112 mm 100 mm 22.5 mm
Operating temperature
0 .. 60 °C
Storage temperature
-
40 .. 85 °C
Standards and Certifi
cations
EM
CE
,
EN 61000 6
-
2
, EN 61000 6
-
4
Environmental
standards
RoHS, WEEE
Vibration resistance
IEC 60721
-
3
-
2
(c
lassification of groups of environmental pa-
rameters and their severities - transportation and handling)
orrosion protection
ISO 12944
-
2
C2
for installation in control cabinets

Remote Access Gateway IGW/941 – Hardware Reference
D o c u m e n t R e v i s i o n 1 . 4
5
2 OVERVIEW
Figure 1: Overview Remote Access Gateway IGW/941

Remote Access Gateway IGW/941 – Hardware Reference
6
D o c u m e n t R e v i s i o n 1 . 4
3 PINOUTS
3.1 Ethernet Interface
Pin
Name
Function
1
TX+
10/100 Mbps LAN, TX+
2
TX
-
10/100 Mbps LAN, TX
-
3
RX+
10/1
00 Mbps LAN, RX+
4
---
Bob
-
Smith Termination
5
---
Bob
-
Smith Termination
6
RX
-
10/100 Mbps LAN, RX
-
7
---
Bob
-
Smith Termination
8
---
Bob
-
Smith Termination
Table 2: Pinout Ethernet interface
LED
Function
Green (left)
10/100BASE
-
T link/activity
Yellow (right)
Not Co
n
nected
Table 3: Ethernet LED functions
3.2 Screw Terminals
Terminal
Function
A1
COM
2
Serial Port
:
RS485 RX /TX+
A2
COM
2
Serial Port
:
RS485 RX /TX
-
A3
Vin 2
4 VDC ±10%
A4
Ground
Table 4: Pinout screw terminals

Remote Access Gateway IGW/941 – Hardware Reference
D o c u m e n t R e v i s i o n 1 . 4
7
3.3 Service ort
Pin
Name
Function
1
RXD1
COM1
Se
rial Port: RS
232
RX
D
2
TXD1
COM1
Serial Port: RS
232 T
X
D
3
GND
Ground
4
RCM
COM1
Serial Port:
Remote Console Mode
5
CTS1
COM1
Serial Port: RS
232 CTS
6
RTS1
COM1
Serial Port: RS
232 RTS
Table 5: Pinout service port
= Cable bridge
To create a serial connection between the IGW/941 and a PC an adapter cable and a null
modem cable are necessary.
The adapter cable is connected with the PC via the null modem cable like shown in fig. 2.
Table 6 shows which service port pins must be connected with the pins of a Sub-D male
connector (DTE, data terminal equipment) to build an adapter cable.
Service Port
Sub
-
D ale Connector (DTE)
Pin 1 (RXD)
Pin 2 (RXD)
Pin 2 (TXD)
Pin 3 (TXD)
Pin 3 (GND)
Pin 5 (GND)
Pin 4 (RCM)
---
All other pins are not connected
.
Table 6: Pinout adapter cable
Figure 2: Serial connection between IGW/941 and P

Remote Access Gateway IGW/941 – Hardware Reference
8
D o c u m e n t R e v i s i o n 1 . 4
4 SIM CARD
The internal SIM card of the IGW/941 can be changed through the slot on the backside.
To remove the SIM card just push it gently with a screw driver until you hear a soft "click".
The SIM card is ejected a few millimeters and can be pulled out easily.
Figure 3: Removing the SIM card
To insert the SIM card just push it by hand as deep as possible into the slot.
Please note:
Pay attention to the correct orientation of the SIM card like shown in fig. 4!
Then use a screw driver to push it gently further into the slot until you here a soft "click".
Figure 4: Inserting the SIM card

Remote Access Gateway IGW/941 – Hardware Reference
D o c u m e n t R e v i s i o n 1 . 4
9
5 HELPFUL LITERATURE
• DNP/9535 hardware reference
• SSV Web ConfigTool User Manual
CONTACT
SSV Software Systems GmbH
Dünenweg 5
D-30419 Hannover
Phone: +49 (0)511/40 000-0
Fa : +49 (0)511/40 000-40
E-mail: [email protected]
Internet: www.ssv-embedded.de
Forum: www.ssv-comm.de/forum
DOCUMENT HISTORY
Revision
Date
Remarks
Name
Review
1.0 2018-02-14 First version WBU SSC
1.1 2018-04-04 Corrected the pinout of table 4 and table WBU HNE
1.2 2018-10-08 Edited chapter 1.3, added adapter cable in chapter 3.3
WBU HNE
1.3 2018-12-04 Updated features of “wireless module” in chapter 1.3 WBU SSC
1.4 2019-07-03 Updated table in chapter 1.3 WBU SSC
The content of this document can change any time without an
nouncement. There is taken over no guaran-
tee for the accuracy of the statements. The user assumes the entire risk as to the
accuracy and the use of
this document. Information in this document is provided ‘as is’ without warranty of any kind. Some names
within this document can be trademarks of their respective holders.
© 2019 SSV SOFTWARE SYSTEMS GmbH. All rights reserve .
Table of contents
Other SSV Gateway manuals

SSV
SSV IGW/935 Application guide

SSV
SSV IGW/910 Application guide

SSV
SSV IGW/935 User manual

SSV
SSV IGW/922 Application guide

SSV
SSV IGW/936A User guide

SSV
SSV RMG/941 Series Application guide

SSV
SSV IGW/920 User manual

SSV
SSV MGW/865 User manual

SSV
SSV RMG/938 User manual

SSV
SSV IGW/925 Installation and user guide