Sven RT-800 User manual

OPERATION
MANUAL
www.sven.fi
RT-500
RT-800
RT-1000
UPS for prolonged
power supply

Congratulations on your purchase of the Sven uninterruptible power supply!
COPYRIGHT
© 2018. SVEN PTE. LTD. Version 1.0 (V 1.0).
This Manual and information contained in it are copyrighted. All rights reserved.
TRADEMARKS
All trademarks are the property of their legal holders.
NOTICE OF RESPONSIBILITY RESTRICTION
Despite the exerted efforts to make this Manual more exact, some discrepancies may occur. The
information in this Manual is given on “as is” terms. The author and the publisher do not bear any
liability to a person or an organization for loss or damage which has arisen from the information
contained in this Manual.
1. BUYER RECOMMENDATIONS
• Unpack the device carefully. Make sure there are no accessories left in the box. Check up the
device for damage; if the product was damaged during transportation, address the firm which
carried out the delivery; if the product functions incorrectly, address the dealer at once.
• Do not switch on the product immediately after you bring it into a room from environment with
negative temperature! After unpacking, the product should be kept in conditions of room tempe-
rature for at least 4 hours.
• Before installing and using the product, read this Manual carefully and keep it for future reference.
• Shipping and transportation equipment is permitted only in the original container.
• Does not require special conditions for realization.
• Dispose of in accordance with regulations for the disposal of household and computer
equipment.
2. PRECAUTIONS
Before operating this device, please carefully read the following safety instructions:
• Connect / disconnect the battery produce when the UPS is disconnected from the mains.
• Before operation a battery should be charged (the battery is not included) for at least 12 hours.
For this purpose the UPS should be switched on without load.
• If a battery is discharged completely or the UPS has not been operated for more than three
months, the battery should be charged completely as well. Failure to comply with storage rules of
batteries will result in their service life decrease.
2
ENG
CONTENTS
1. BUYER RECOMMENDATIONS....................................................................
2. PRECAUTIONS .....................................................................................
3. PACKAGE CONTENTS ...........................................................................
4. TECHNICAL DESCRIPTION......................................................................
5. CONNECTION AND OPERATION ...........................................................
6. TROUBLESHOOTING ............................................................................
7. TECHNICAL SPECIFICATIONS ..................................................................
2
2
3
3
6
8
9
UPS for prolonged
power supply

3
ENG
Operation Manual RT-500/RT-800/
RT-1000
• The connected load power must not exceed the rated power indicated in the technical
specifications table.
• Place the UPS in closed rooms with the regulated temperature and humidity of the air. The UPS
case temperature can be risen during its operation, it is a normal phenomenon.
• Do not open the battery: escaped electrolyte is dangerous for the skin and eyes.
• Disconnect the UPS from the mains before connection/disconnection of load cables to the UPS
to avoid electric shock.
• In case of an emergency, turn off the UPS and disconnect the power cord from the mains.
• It is strictly prohibited to open the device case – there is high voltage inside. In case of any
problems, connect to the service center. The list of authorized service centers is available on
www.sven.fi.
• UPS should be serviced by qualified specialists only.
• It is strictly prohibited to use the UPS in the following conditions:
- outdoors;
- in dusty environment containing highly inflammable gases;
- at a temperature higher than 40 °C or lower than 5 °C;
- at the relative humidity level higher than 90 %;
- in direct sunlight or close to heating elements;
- in places with elevated vibration.
• In case of fire use a powder fire extinguisher only, as using water can cause electric shock.
• Try to install the UPS in close proximity to a power supply, in such way it will be easier to unplug
the device as may be required.
Note. Periodic maintenance of the device is recommended, as well as periodic control of the
battery state to provide the device operability.
3. PACKAGE CONTENTS
• Uninterruptible power supply — 1 pc
• Operation Manual — 1 pc
• Warranty card — 1 pc
4. TECHNICAL DESCRIPTION
Operating principle
• Models of SVEN RТ are designed to operate with lead-acid maintenance-free 12 V batteries of
AGM type.
• Models of RТ series fall in the line-interactive uninterruptible power supply of continuous
action with prolonged back-up time. Principle of their operation is based on the transformation
of direct current of external batteries to alternating current. Current waveform at the output is
the regular sinusoidal wave.
• Its primary function is the power supply for household and industrial equipment, which is
critical to the input current waveform (boiler equipment, automation systems with equipment
with program control (servers, databases, etc.) with medical equipment).
Caution! There is high voltage inside on unsolated components,
which can result in electric shock.

4
ENG
• The device is equipped with the automatic voltage regulator (AVR). The built-in regulator
enables to provide correct power supply at overvoltage/undervoltage of the mains without
going to the battery operation mode.
• The automatic start function provides automatic switching on when there is power supply.
With input voltages 160 V or less, as well as 260 V or more the automatic start is not activated.
• The three-stage switch of charging current enables the user to connect batteries of different
capacities depending on the required time to provide the power backup. It is recommended for the
battery with the capacity 20 – 50 А•h to use the position L (3-5 A) of the switch, with the capacity 50 –
100 А•h to use the position M (7-9 A), with the capacity 100 – 200 А•h to use the position Н (13-15 A).
Recommendations regarding selection of batteries
• Select the capacity of a battery (batteries) depending on the connected load power and required
time of power standby, see the table 1 below. Based on the selected capacity, choose a certain
battery (batteries).
• Storage conditions of batteries must conform to the requirements of the battery producer.
• We recommend to use SVEN SV12170, SVEN SV12500, SVEN SV121000 batteries.
Notes:
• When two or more batteries are used, they should be of one type and have the same capacity (if
their capacities are different, the batteries will have different internal resistance and due to this the
charge level will be different).
• Batteries should be connected in parallel, when several batteries are used simultaneously.
Additional cables (to be purchased separately) will be required to connect extra batteries. When
two or more batteries are connected, the plus terminal of one battery is connected to the plus
terminal of the other battery, minus terminals of batteries are connected similarly. The connecting
cables must have a sufficient cross-section and a minimum length.
Features
• Continuous action with prolonged back-up time
• Built-in automatic voltage regulator
• Pure Sine Wave
• Microprocessor control
• Protection against short circuit in connected load to UPS, as well as against overload
RT-500
RT-1000
RT-800
12V/50 А · h
12V/75 А · h
12V/100 А · h
12V/150 А · h
12V/200 А · h
3 h
5 h
7 h
12 h
15 h
1.5 h
2.3 h
3 h
5 h
7 h
0.7 h
1.5 h
2 h
3 h
4.5 h
0.5 h
1 h
1.5 h
2 h
3 h
0.4 h
0.8 h
1 h
1.5 h
2.5 h
0.4 h
0.8 h
1 h
1.5 h
2.5 h
0.3 h
0.5 h
0.7 h
1 h
2 h
Load
100 W
Load
200 W
Load
300 W
Load
400 W
Load
480 W
Load
500 W
Load
600 W
Battery
capacity
Table 1. Selection of batteries
UPS for prolonged
power supply

ENG
5
Operation Manual RT-500/RT-800/
RT-1000
• Protection against overvoltage or undervoltage in the mains
• IP-20 ingress protection
• Three-stage switch of charging current
• Self-diagnosis after switching on
• Indication of operation modes on LCD display
• Mode switchover time 8 msec
• Automatic start function
• Low noise level
Description
a OUTPUT VOLTAGE: output voltage indicator
b INPUT VOLTAGE: input current indicator
c LOADING CAPACITY: device load indicator
d BATTERY: battery charge level indicator
e BACKUP: operation mode from battery.
It lights, when there is no input voltage or its
value goes beyond its rate
f CHECK: error indicator
g UTILITY: mains operation indicator
h OVERLOAD: overload indicator
i LCD display
j Signal: sound signal on/off switch
k : UPS on/off switch
l Audio alarm: on/off switch of all sound signals
m Fuse: resettable automatic temperature fuse (pres to reset)
n Output ~220 V: socket
o Input: built-in power cord
a
b
c
ed f g h
B AT T E RY
Fig. 1. LCD display of UPS
���������� ���������
0
-100
-200
-300
-400
100
10 20 30 40
200
300
400
Fig. 2. RT-500/800/1000 front panel
kj
i
Alarm
Pure sine wave

ENG
6
* Rear panel RT-1000 is the same as that of RT-800.
p 12 V DC: built-in cables to connect battery
q Charging current: switch to select charging current for the battery
5. CONNECTION AND OPERATION
• Place the set (UPS + batteries) in an appropriate position with proper ventilation (free space
around the UPS must be not less than 25 cm).
• Set the three-position switch q on the rear panel of UPS in position, which corresponds to the
capacity of a connected battery, according table 2.
• Connect the battery to the UPS using built-in cables p, observe the polarity.
ATTENTION!!!
• Sparkling is allowed at the touch of power terminals during battery connection to the UPS.
• Before the first UPS using, the battery should be charged without load for not less than 12 hours
(full charge time may vary depending on the capacity and discharge of the connected battery level).
• After that connect the UPS to the grounded single-phase network with the help of power cable o.
The LCD display i will be switched on, the buzzer beeps 4 times. The output voltage indicator a will
display the figure “220”. You don't need to turn on the UPS after its connection to the network with
the button k, the “autostart” function will start it automatically.
• The battery must be charged. To do this, the UPS is to be in switched on position till the battery is
charged completely (5 segments of the battery indicator must light).
• Connect devices-consumers to the UPS when it is switched off. To do this, insert plugs of
consumers into UPS sockets n.
• Insert the UPS plug into a socket once more, “autostart” function will start it automatically. LCD
display i will turn on, buzzer beeps 4 times shortly. The figure “220” will be displayed on the output
voltage indicator a. Then turn on the connected devices using their switches (turn on the most
powerful device first and the most low-powered should be last turned on the last).
Notes:
• When the occasion requires disconnecting the UPS enforced, unplug devices-consumers and turn
off the UPS in manner aforesaid. Press and hold the button h within 4 seconds to restart the UPS.
The buzzer beeps four times and the output voltage indicator a will display the figure “220”.
• If the UPS is not used for a long time, the battery is to be charged once every three months. We
recommend to read the manufacturer’s manual for the proper maintenance of the battery.
• If the UPS is not used for a long time, unplug it and disconnect the battery set. As this UPS has the
autostart function, a power supply failure will result in the UPS automatic starting.
Fig. 3. Rear panel of RT-500 Fig. 4. Rear panel of RT-800*
UPS for prolonged
power supply
Circuit Breaker
(press to reset)
Circuit Breaker
(press to reset)
Output ~220 V
3-5A
7-9�
13-15�
12 В
Input
~220 V, 50 Hz
Alarm
Сделано в Китае/
Made in China.
Charging Rate
lp
q
m
n
o
3-5A
7-9�
13-15�
Charging Rate
Сделано в Китае/
Made in China.
lp
q
m
n
o
12 В
Output ~220 V
Output ~220 V
Input
~220 V, 50 Hz
Alarm
ON
OFF
ON
OFF

ENG
7
Operation Manual RT-500/RT-800/
RT-1000
Cold start function
• The UPS can be switched on without connection to the mains using the cold start function. In
order to switch on the UPS, press and hold down the button k within 4 sec. The buzzer beeps four
times, the output voltage indicator a displays the figure “220” and the power will be supplied to
devices-consumers.
Note. It is not recommended to use the cold start function when the connected load is large.
Sound alarm and protection
• At the instant the UPS starts to use power from batteries (when there is power failure), it beeps
4 times. Then the UPS beeps every 30 seconds, when it operates from batteries. This function can
be switched off. To do this, press and hold down the button j within 2 sec., the buzzer beeps one
time and signals will be over. When beeps are required, repeat the procedure. You can also to turn
off all sound signals by pressing the button l on the rear panel of UPS. Press the button l to turn
on all sound signals.
• If the battery capacity is low (while operating from batteries), the UPS beeps every second. When
the batteries are fully discharged UPS will frequent beeps for 20 seconds and then turns off
automatically. If you turn off the button beeps l, signal low battery charge will not supplied.
• When the battery residual voltage is lower than 10.5 V, the UPS is switched off.
• When load is too high (110 – 120 %), the UPS delivers frequent intermittent warning beeps within
20 sec., then it will turn off the load automatically. When load is 120 % or more the UPS delivers
a single beep and then it is turned off automatically.
• When the UPS protection is activated, load power supply, turn on the device again by pressing
the front panel button.
Three-stage switch of charging current
It enables the user to connect batteries of different capacities depending on the required time of
providing back-up power.
Storage conditions
• The temperature and humidity conditions in premises, where the device placement is intended,
must correspond to the norms indicated in the Technical Specifications table.
• The UPS must be stored with batteries full charged.
• Storage conditions of batteries should comply with the manufacturer’s requirements.
from 20 to 50 А · h
from 50 to 100 А · h
from 100 to 200 А · h
low (3 A ~ 5 A)
middle (7 A ~ 9 A)
high (13 A ~ 15 A)
L
M
H
Charging current Switch position
Battery capacity
Table 2. Selection of the charging current for a battery depending on its capacity

ENG
8
If none of the above methods can solve the problem, please seek professional advice at your
nearest service center. Never attempt to repair the product yourself.
6. TROUBLESHOOTING
Problem
The UPS is connected
to the mains, but the
indicator does not
light.
The UPS beeps and
operates in the
off-line mode even
with normal voltage in
the mains.
The UPS operates
from the mains, but
does not operate in
the off-line mode.
The UPS beeps long
during operation from
the mains.
The UPS does not
provide the expected
time of operation in
the off-line mode or it
is switched off.
Cause
1. The button k is not pressed.
2. Input fuse has come into action.
3. Unreliably connected cables.
1. The UPS found depressions or
surges in input voltage and has
gone to the standby mode.
2. Input fuse has come into action.
3. Poor contact in the UPS connec-
tion circuits to the mains.
1. Batteries are discharged greatly.
2. Defective batteries.
3. The UPS is to be repaired.
4. Unreliably connected cables.
Overload.
1. Batteries are discharged greatly.
2. Defective batteries.
3. Unreliably connected cables.
Solution
1. Press button k.
2. Switch off the load. Press the fuse
button. If the UPS operation is
normal, check the load power.
3. Check cable connections to
batteries.
1. It is normal phenomenon. The UPS
protects the equipment against
voltage disorders of the mains.
2. Disconnect the load. Press the
fuse button. If the UPS operation is
normal, check the load capacity.
3. Check the UPS connection
reliability to the mains.
1. Disconnect all equipment and
charge batteries in full.
2. Replace batteries.
3. Consult with the service center.
4. Check cable connections to
batteries.
Decrease the connected load power.
1. Charge batteries in full.
2. Replace batteries.
3. Checkt the connection reliability of
cables to batteries.
UPS for prolonged
power supply

9
ENG
Operation Manual RT-500/RT-800/
RT-1000
Notes:
• Technical specifications given in this table are supplemental information and cannot give occasion to
claims.
• Technical specifications and package contents are subject to change without notice due to the im-
provement of SVEN production.
Type
Voltage, V
Charging rate, A
Normal conditions and AVR
Operation mode from batteries
AVR operation mode
Operation mode from batteries
7. TECHNICAL SPECIFICATIONS
Total power, VА
Active power, W
Overload protection acting, % of the rated power
Input voltage, V
Output voltage, V
Frequence, Hz (input/output)
Number of phases
Coefficient of efficiency (during operation from
batteries), %
Operation mode
Output voltage
waveform
Protection
Cooling type
Beeps
Switching time, msec
Battery: plug-in
external (optional)
Environment temperature in the operating mode, ° C
Humidity, %
Noise level, dB
Dimensions, mm
Weight, kg
120
~140 – 275 ± 5 %
~220 ± 10 %
50 / 50
1
65
continuous, long-lasting
regular sinusoid
against high voltage/undervoltage,
overload, short circuit
against discharge, overload, short circuit
passive / active
on/off low battery charge, overload, error
≤ 8
non-serviceable leakproof
lead-acid batteries
12
low (3 ~ 5); middle (7 ~ 9); high (13 ~ 15)
5 to 40
10 ~ 90, without condensation
< 56
Parameters Models RT-500 RT-800 RT-1000
500
300
800
480
1000
600
300 × 270 × 140
5.66 8.53 9.9
Technical support is on www.sven.fi.

Model: RT-500/800/1000
Импортер в России:
OOO «РЕГАРД»,
105082, г. Москва,
ул. Фридриха Энгельса, д. 75, стр. 5.
Уполномоченная организация в России: ООО «РТ-Ф»,
105082, г. Москва, ул. Фридриха Энгельса, д. 75, стр. 5.
Условия гарантийного обслуживания смотрите
в гарантийном талоне или на сайте www.sven.fi.
Гарантийный срок: 24 мес. Срок службы: 5 лет.
Производитель: «СВЕН ПТЕ. Лимитед», 176 Джу Чиат Роуд,
№ 02-02, Сингапур, 427447. Произведено под контролем
«Свен Скандинавия Лимитед», 48310, Финляндия, Котка,
Котолахдентие, 15. Сделано в Китае.
Manufacturer: SVEN PTE. LTD, 176 Joo Chiat Road,
№ 02-02, Singapore, 427447. Produced under the
control of Oy Sven Scandinavia Ltd. 15, Kotolahdentie,
Kotka, Finland, 48310. Made in China.
® Registered Trademark of Oy SVEN
Scandinavia Ltd. Finland.
RT-500
RT-800
RT-1000
UPS for prolonged
power supply
This manual suits for next models
2
Table of contents
Other Sven UPS manuals

Sven
Sven Pro+ 400 User manual

Sven
Sven PRO 400 User manual

Sven
Sven Reserve Home User manual

Sven
Sven PRO 600 User manual

Sven
Sven SMART L 2000 User manual

Sven
Sven RT-500 User manual

Sven
Sven Pro User manual

Sven
Sven Power Pro+ 1000 User manual

Sven
Sven Power Pro+ 625 User manual

Sven
Sven UP-L800E User manual