Selection and conguration Interrogation
CHA+ / CHA- Change measurement direction CHA? Measurement sense?
FCT0 ...9...A...F Assign «favourite» function FCT? «favourite» function active?
MM / IN Change measurement unit UNI? Measurement unit active?
KEY0 / KEY1 Lock / unlock keypad KEY? Keypad locked?
MUL [+/-]xxx.xxxx Modify multiplication factor MUL? Multiplication factor?
PRE [+/-]xxx.xxx Modify preset value PRE? Preset value?
REF1 / REF2 Change active reference REF? Reference active?
STO1 / STO0 Activate / de-activate HOLD STO? Status of HOLD function?
TOL ON / TOL OFF Activate / de-activate tolerances TOL? Current tolerance limit values?
ECO1 / ECO 0 Activate / de-activate economic mode ECO? Current economic mode
LCAL dd.mm.yy Modify last calibration date LCAL? Date of last calibration?
NCAL dd.mm.yy Modify next calibration date NCAL? Date of next calibration?
NUM x...x (up to 20chars) Modify the instrument number NUM? Instrument number?
TOL +/-xxx.xxx +/-yyy.yyy Inputting tolerance limits ? Current value (mode Tol, value followed by <=>)
MIN /MAX /DEL /NOR Selecting MIN, MAX, Delta, Normal mode MOD? Active mode (MIN, MAX, Delta or Normal)?
CLE Re-initialisation of MIN, MAX or Delta SET? Main instrument parameters?
UNI1 / UNI0 Activate / de-activate change of units ID? Instrument identication code?
OUT1 /OUT0 Activate / de-activate contin. data transmission Maintenance functions
PRE ON / PRE OFF Activate / de-activate Preset function BAT? Battery status (BAT1 = OK, BAT0 = low battery)
PRE Recall Preset OFF Switch-off (wake up using a button or RS)
SET Zero reset RST Re-initialisation of the instrument
RES1 / RES2 Change of resolution SBY Put instrument in stand-by (SIS)
SBY xx xx number of minutes before stand-by
BT0/BT1 Activate / de-activate Bluetooth®module
BTRST Reset pairing information
7. List of the main commands
Selection and conguration Interrogation
CHA+ / CHA- Change measurement direction CHA? Measurement sense?
FCT0 ...9...A...F Assign «favourite» function FCT? «favourite» function active?
MM / IN Change measurement unit UNI? Measurement unit active?
KEY0 / KEY1 Lock / unlock keypad KEY? Keypad locked?
MUL [+/-]xxx.xxxx Modify multiplication factor MUL? Multiplication factor?
PRE [+/-]xxx.xxx Modify preset value PRE? Preset value?
REF1 / REF2 Change active reference REF? Reference active?
STO1 / STO0 Activate / de-activate HOLD STO? Status of HOLD function?
TOL ON / TOL OFF Activate / de-activate tolerances TOL? Current tolerance limit values?
ECO1 / ECO 0 Activate / de-activate economic mode ECO? Current economic mode
LCAL dd.mm.yy Modify last calibration date LCAL? Date of last calibration?
NCAL dd.mm.yy Modify next calibration date NCAL? Date of next calibration?
NUM x...x (up to 20chars) Modify the instrument number NUM? Instrument number?
TOL +/-xxx.xxx +/-yyy.yyy Inputting tolerance limits ? Current value (mode Tol, value followed by <=>)
MIN /MAX /DEL /NOR Selecting MIN, MAX, Delta, Normal mode MOD? Active mode (MIN, MAX, Delta or Normal)?
CLE Re-initialisation of MIN, MAX or Delta SET? Main instrument parameters?
UNI1 / UNI0 Activate / de-activate change of units ID? Instrument identication code?
OUT1 /OUT0 Activate / de-activate contin. data transmission
Maintenance functions
PRE ON / PRE OFF Activate / de-activate Preset function BAT? Battery status (BAT1 = OK, BAT0 = low battery)
PRE Recall Preset OFF Switch-off (wake up using a button or RS)
SET Zero reset RST Re-initialisation of the instrument
RES1 / RES2 Change of resolution SBY Put instrument in stand-by (SIS)
SBY xx xx number of minutes before stand-by
MAC? Bluetooth®MAC address ?
BT0/BT1 Activate / de-activate Bluetooth® module
BTRST Reset pairing information