Installation Procedure
1. Push valve bodies through holes in sink from
underneath (both valve bodies shall include a red striped
hose). Make sure ange nuts and mounting washers are
on underside of sink. Put gasket (LN-129) over valve
body. read escutcheon (LN-128) onto valve body. e
top of the valve spindle should measure 1-7/8” from
mounting surface (See rough in drawing).
2. read collar (LN-112) on to valve body until it reaches
the escutcheon (LN-128).
3. CRP handle installation: Ensure valve spindle is rotated
to the OFF position. Place handle on valve spindle and
thread screw (LN-121) into valve.
4. Tighten ange nuts and mounting washers from
underneath sink and secure with mounting screws if
necessary.
5. Install spout (LN-254A) and centerbody (LN-188)
through center in sink hole from above sink. Secure
spout to sink with washer (LN-138) and nut (SPF-26).
Washer (LN-138) at side should face back of the sink.
read tee (LN-189) to bottom of centerbody (LN-188).
6. read ex hose adapters into tee (LN-189) using pipe
sealant on the threads. Attach ex hoses to ex hose
adapters.
7. Connect hot supply to le tube and cold supply to right
tube using appropriate connectors.
8. Pop-up drain installation:
a ) Remove pop-up plug, tail piece and ange from
the drain body. Make sure that locknut is threaded
all the way down onto the body with at friction
washer in middle and beveled washer on top.
b ) Apply plumbers putty or sealant to bottom of
ange.
c ) Install drain body through drain opening in
lavatory and screw ange onto the drain body
making sure that the threads are completely
engaged for proper sealing and strength of the
connection. Apply joint compound to all threaded
parts to insure proper seal. Apply putty or teon
tape to tail piece before attaching to drain body.
d ) Tighten locknut to compress the beveled ange
evenly across the bottom of the drain opening taking
care not to over tighten the locknut, causing damage
to the lavatory. Apply teon tape (clockwise) on tail
piece and thread into outlet of body.
e ) Insert pop-up plug and pivot rod into body and
tighten retaining nut until the ball is seated on the
ball washer.
Note: e pop-up plug can be installed either in the
removable or non-removable position, depending
on the location of the hole located in the guide at
the bottom of the plug.
f ) Slide the pivot rod through one side of the spring
clip, then the appropriate adjustment hole and then
other side of the spring clip.
g ) Insert li rod through faucet housing and the top of
the li strap and secure it in place by tightening the
screw.
Note: To insure proper operation of li rod and
pop-up, some adjustment of the linkage may be
required.
ere are two possible adjustment points:
1) li strap to li rod
2) li strap to pivot rod
8. It is very important to thoroughly ush the supply lines
to prevent foreign matter, i.e. copper chips, sand, stones,
etc. from damaging the sealing surfaces of cartridge.
Remove aerator and open hot and cold to full open then
open both supplies. Let water run through hot and cold
long enough to ush supply lines thoroughly. Shut o
faucet and replace aerator. Check for leaks.
Replacing cartridge (KN-113 or KN-114):
1. Remove plug button (LN-243H or LN-243C), loosen
Phillips head screw (LN-121) and remove handle (LN-
177).
2. Remove collar (LN-112) by turning counter clockwise.
Caution: Do not use wrench as this may damage the
surface nish.
3. Place wrench on cartridge hex nut (KN-113, KN-114).
Turn wrench counterclockwise until cartridge is
removed.
4. Install new cartridge. Turn cartridge with wrench until
cartridge does not turn easily then turn 1/4 to 1/2 turn
further. Reassemble handle in reverse fashion.
Widespread Lavatory Faucet SLW-4412
Installation and Service Instructions
Carrington®
Faucet meets ASME A112.18.1/CSA B125.1, NSF/ANSI 61.9,
NSF/ANSI 372, WaterSense at 1.0 gpm & 1.5 gpm Certied by
NSF International
Caution: Be sure to turn o hot and cold water supplies
before installing or servicing faucet.
Symmons Industries, Inc. ■31 Brooks Drive ■Braintree, MA 02184
Phone: (800) 796-6667 ■Fax: (800) 961-9621
Website: symmons.com ■ Email: [email protected]
Copyright © 2019 Symmons Industries, Inc. ■ZV-577 REV H ■111419
1/2"-14 NPSM
Hole size
1-1/4" (32 mm)
4" (102 mm) min
Flexible hose
2" (51 mm)
8"(203 mm) min
16"(406 mm) max
Deck thickness
1-3/8" (35 mm) max
Note: Dimensions subject to change without notice
1-9/16" (40 mm)
5-13/16"
(148 mm)
2-5/16" dia
(59 mm)
1" dia
(25 mm)
5/8" dia
(16 mm)
Hole size
1-1/2" (38 mm) min
1-5/8" (41 mm) max
7-1/8"
(181 mm)
7-1/4"
(184 mm)
4-5/32"
(106 mm) 1-7/8"
(48 mm)
3/4" (19 mm)
2-7/16"
(62 mm)
Dimensions Carrington Two Handle Widespread Lavatory Faucet, SLW-4412
Parts Assembly Carrington Two Handle Widespread Lavatory Faucet, SLW-4412
KN-114 Valve cartridge (1)
L-26 O-ring (2) (plug button)
LN-112* Collar (2)
LN-121 Handle screw, M4x12, SS, panhead (2)
LN-128* Escutcheon, widespread (2)
LN-129 Gasket, Escutcheon (2)
LN-138 Washer
LN-150 O-ring (2)
LN-177* Cross handle (2)
LN-185 Gasket, spout
LN-188 Centerbody
LN-189 Centerbody tee
LN-243C Plug button, porcelain (cold)
LN-243H Plug button, porcelain (hot)
LN-254A* Spout
P-108CL12* Lift rod (for pop-up drain assembly)
SPF-26 Nut, Hex (centerbody)
WSF-CRP-KIT Handle kit (qty 2 handles)
*For Decorative Finish Faucets add sufx to parts
marked with an asterisk as follows:
Sufx -STN Radiance® satin nish
P-26*
Grid drain
(optional)
RL-154LR*
Pop-up drain assembly
(without lift rod)
KN-114
LN-254A
LN-185
LN-138
SPF-26
LN-150
KN-114
LN-189
LN-243H (1)
Handle kit
(2 handles)
P-108CL12
LN-243C (1)
L-26 (2)
LN-121 (2)
LN-177 (2)
LN-112 (2)
LN-128 (2)
LN-129 (2)
Aerator insert
2.2 gpm
Flange nut
Mounting washer
Mounting screws
Flex hose adapter
Flex hose
LN-188
Part Number
Standard Aerator
Aerator
(ow regulator)
2.2 gpm (8.3L/min) ----
1.5 gpm (5.7L/min) LN-741*
1.0 gpm (3.8L/min ----
WARNING: This product can expose you to chemicals including lead, which is known to the state of California to cause
cancer, birth defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.

Other Symmons Plumbing Product manuals

Symmons Dia 3503-H321-V-CYL-B-TRM Manual

Symmons

Symmons Dia 3503-H321-V-CYL-B-TRM Manual

Symmons Identity S-6704 Manual

Symmons

Symmons Identity S-6704 Manual

Symmons Symmetrix S-20-BH Series Quick guide

Symmons

Symmons Symmetrix S-20-BH Series Quick guide

Symmons SLC72121.2 Manual

Symmons

Symmons SLC72121.2 Manual

Symmons Oxford Trim Series Installation instructions

Symmons

Symmons Oxford Trim Series Installation instructions

Symmons Duro SLW3612PP Manual

Symmons

Symmons Duro SLW3612PP Manual

Symmons Winslet Series Manual

Symmons

Symmons Winslet Series Manual

Symmons SLW-8602-1.5 User manual

Symmons

Symmons SLW-8602-1.5 User manual

Symmons Origins ActivSense S6960B User manual

Symmons

Symmons Origins ActivSense S6960B User manual

Symmons Duro SK3610PO Manual

Symmons

Symmons Duro SK3610PO Manual

Symmons Allura Series Quick guide

Symmons

Symmons Allura Series Quick guide

Symmons Degas 542TS-ORB Manual

Symmons

Symmons Degas 542TS-ORB Manual

Symmons SLS-5512-STN User manual

Symmons

Symmons SLS-5512-STN User manual

Symmons Sereno Trim TA-10 T-12A S4300TRMTC Installation instructions

Symmons

Symmons Sereno Trim TA-10 T-12A S4300TRMTC Installation instructions

Symmons Ballina 522TS Manual

Symmons

Symmons Ballina 522TS Manual

Symmons Carrington SRT-4470 Quick guide

Symmons

Symmons Carrington SRT-4470 Quick guide

Symmons Symmetrix S2502 Series Manual

Symmons

Symmons Symmetrix S2502 Series Manual

Symmons Duro SLS3622PP Manual

Symmons

Symmons Duro SLS3622PP Manual

Symmons 0142-06-L/HDHSB-SS-TRM User manual

Symmons

Symmons 0142-06-L/HDHSB-SS-TRM User manual

Symmons Verity SLS4912PP User manual

Symmons

Symmons Verity SLS4912PP User manual

Symmons Allura S-4701-TRM Manual

Symmons

Symmons Allura S-4701-TRM Manual

Symmons identity 6700 Manual

Symmons

Symmons identity 6700 Manual

Symmons Symmetrix S-250 Series Quick guide

Symmons

Symmons Symmetrix S-250 Series Quick guide

Symmons Naru Trim Series Installation instructions

Symmons

Symmons Naru Trim Series Installation instructions

Popular Plumbing Product manuals by other brands

Omnires TK104-PLUS-3.35+64-SBP Installation and Maintenance

Omnires

Omnires TK104-PLUS-3.35+64-SBP Installation and Maintenance

Luxart Lumino LUM341 installation manual

Luxart

Luxart Lumino LUM341 installation manual

Hans Grohe Ecostat 15346000 Assembly instructions

Hans Grohe

Hans Grohe Ecostat 15346000 Assembly instructions

Luxart Liscio LI137-CP Installation

Luxart

Luxart Liscio LI137-CP Installation

Watermark H-Line 115 Series Important installation information

Watermark

Watermark H-Line 115 Series Important installation information

Spectrum Brands Pfister Park Avenue LG89-XFE Quick installation guide

Spectrum Brands

Spectrum Brands Pfister Park Avenue LG89-XFE Quick installation guide

Hans Grohe ShowerSelect 15743 1 Series Installation and user instructions

Hans Grohe

Hans Grohe ShowerSelect 15743 1 Series Installation and user instructions

agape SPOON XL ACER0713 Assembly instructions

agape

agape SPOON XL ACER0713 Assembly instructions

Hans Grohe Focus 100 CoolStart 31509000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Focus 100 CoolStart 31509000 Instructions for use/assembly instructions

Grizzly T10121 instructions

Grizzly

Grizzly T10121 instructions

Hans Grohe 06646000 Installation/User Instructions/Warranty

Hans Grohe

Hans Grohe 06646000 Installation/User Instructions/Warranty

Pfister Designer F-049-DE Quick installation guide

Pfister

Pfister Designer F-049-DE Quick installation guide

Vallone NERO 01 installation instructions

Vallone

Vallone NERO 01 installation instructions

Blanco Stellar Equal Double Bowl 441020 Specifications

Blanco

Blanco Stellar Equal Double Bowl 441020 Specifications

Hans Grohe Ecostat S 04232340 manual

Hans Grohe

Hans Grohe Ecostat S 04232340 manual

VADO VECTA AXCES AX-VEC-106/CD-CP Instruction booklet

VADO

VADO VECTA AXCES AX-VEC-106/CD-CP Instruction booklet

Sanela SLP 23Z Instructions for use

Sanela

Sanela SLP 23Z Instructions for use

Grohe K7 32 178 installation instructions

Grohe

Grohe K7 32 178 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.