ELECTRICAL INSTALLATION
• The electrical power supply system must be in compliance with national
statutory regulations.
• The product must be connected to the mains power via an omnipolar switch (I)
with an opening between contacts that guarantees complete disconnection in
excess voltage category III conditions (minimum 3 mm), installed outside areas
0,1,2,3 (IEC 60364-7-701).
• Make certain the appliance is connected to the power source by way of a
residual current device with minimum threshold =30mA.
• The electrical connection ( ) must include a connection to the earth
system and must be:
- permanent
- able to handle the rated current (see data plate).
- specified to liquids ingress protection category IPX5.
EQUIPOTENTIAL BONDING
The appliance must be equipotentially bonded by making the connection to the
terminal positioned at the
base of the electric motor/pump unit.
CONNECTION FOR ALARM
SYSTEM
The product is prewired for connection
to the bathroom alarm system (open/
close contact, voltage-free).
HYDRAULIC INSTALLATION
Prepare hot and cold water connections for water supply and the drain connection.
If the hardness of the water of the mains water system is high (>200 mg/litre), it is
advisable to install a water softener to guarantee a good functioning of the
hydromassage installation.
BATHTUBS WITH COMBINED OVERFLOW AND FILLER SPOUT
A DB type device must be installed at least 150 mm above the bathtub rim in
accordance with EN 1717 standard.
ART. 382 TOP
P - Electric Control Panel
S - Remote control
- Dispenser
cap (Ø 50)
BASIC
P- Electric Control Panel
D- Dispenser (Ø 50)
A- Air Regulation (Ø 50)
C- Chromotherapy
C/P
H = 620
H = 620
L N
L: PHASE
N: NEUTRAL
: ALARM SYSTEM (MAX 230/2 40V A.C. 3A)