Factory Defaults Premier 48, 88 & 168 Factory Defaults and Quick Reference Guide
2 INS222
1. Factory Defaults
Menu Option Default
User Codes
Setup Users User 00 (Engineer) 1234
User 01 (Master) 5678
All Other Users Not Defined
1. Zone Setup
Zones Types 1 Entry/Exit 1
2 Guard Access
3 - 8 Guard
All Other Zones Not Used
Zone Areas All Zones Area A
Zone Text All Zones Not Defined
Zone Chime All Zones Silent
Remote Test All Zones Off
2. Area Programming
Timers Exit Delay - All Areas 030 Seconds
Entry Delay 1 - All Areas 045 Seconds
Entry Delay 2 - All Areas 045 Seconds
2
nd Entry Dly - All Areas 000 Seconds
Bell Delay - All Areas!000 Minutes
Bell Duration - All Areas 015 Minutes
Coms Delay - All Areas 000 Seconds
Part Bell Dly - All Areas 000 Seconds
Arming Modes All Areas!Entry/Exit
Area Arm Suites All Suites!No Areas
Area Suite Text All Suites!Not Defined
Suite Arm Modes All Suites!Timed
Area Options 1: Auto Part Arm!No Areas
2: Part Arm Instant!No Areas
3: Part Arm Silent!No Areas
4: Remote Arm All Areas
5: Remote Disarm!All Areas
6: Panel Tamper!Area A
7: Bell Tamper!Area A
8: Auxiliary Tamper!Area A
9: Panel Speaker!All Areas
10: Bell & Strobe op!All Areas
11: Alarm Eng Reset!No Areas
12: Confirmation Reset!All Areas
13: Tamper Eng Reset!All Areas **
14: Anti-code Reset!All Areas
15: Phone Line Fault!Area A
16: Arm With L/Fault!Area A
17: AC Mains Fail!Area A
18: Arm With AC Fail Area A
19: Full Arm Coms!All Areas
20: Part Arm Coms!No Areas
21: Unarm Fire Coms!No Areas
22: Unarm Tamper Coms!No Areas **
23: Auto Arm Areas!No Areas
24: Area A Foyer!No Areas
25: Log Part Omits!No Areas
26: Multi Knock Area!No Areas
27: UDL Keypad!All Areas
28: Auto Chime (C2A)!No Areas
29: Confirm In Entry!No Areas
30: Conf. After Entry!All Areas
31: Part Arm Enabled!ALL Areas
32: Bell Squawk!No Areas
33: Fob After Entry!No Areas
34: Armed = Coms !No Areas
35: 2 Wire Smoke!No Areas
36: Faults Eng Reset!All Areas **
37: L/Fault Eng Rst!All Areas **
38: AC Fail Eng Rst!No Areas
39: Anti-Masking when Armed No Areas
Area Text All Areas!Not Defined
Menu Option Default
3. Global Options
System Timers 1: Exit Settle Time 008 Seconds
2: Global Bell Dly. 000 Minutes
3: Global Bell Dur. 015 Minutes
4: Double Knock Dly 007 Seconds
5: Beam Pair Time 060 Seconds
6: Activity Delay 024 Hours
7: Abort Delay 180 Seconds
8: Courtesy Time 030 Seconds
9: Defer Arming By 030 Minutes
10: Auto Arm Delay 030 Minutes
11: Menu Time Out 180 Seconds
12: Pulse Period 1 010 Seconds
13: Pulse Period 2 020 Seconds
14: Pulse Period 3 030 Minutes
15: Line Fault Delay 000 Minutes
16: AC Off Delay 005 Minutes
17: Batt Test Period 024 Hours
18: Batt Test Time 010 Seconds
19: Soak Test Time 014 Days
20: Service Interval 000 Weeks
21: Test Call Every 000 Hours
22: Min Random Time 000 Seconds
23: Max Random Time 060 Seconds
24: Door Strike Time 005 Seconds
25: Zone Response 008x08mSec.
26: Keypad PA Delay 060 Seconds
27: Confirmation Dly 060 Minutes
28: Warning Delay 000 Minutes
29: Keypad Lock time 090 Seconds
30: Eng. Log Off Dly 060 Minutes
31: Fire Bell Delay 000 Minutes
32: Forced Entry Dly 005 Seconds
33: Supervision Time 120 Minutes
34: Poll IP Every 000 Minutes
System Config. 00: Bell on Arm Fail No Bell
01: Bell is an SCB SAB
02: Clock is 12Hr 24Hr
03: Manual BST/GMT Auto
04: Hide Armed Areas View
05: Area Bell Time Global
06: 24Hr Omit Local Global
07: Leave Omits Remove
08: Enforce Com Delay Override
09: NVM is Locked Unlocked
10: Engineer Only User + Engineer
11: Chime Visible Audible
12: Omit Tampers NO YES **
13: Offline Printing Online
14: View Act. Fault Hide
15: Hide Exit Errors Hide
16: Code Tampers Enable
17: Code Tamp Alarms Locks **
18: Areas 1-8 & I-P A-H & I-P
19: Man. Area Select Auto
20: Normal Text Predictive
21: Zone Short = Active Tamper
22: R/R=Silence/RST Reset Only
23: User Code Latch Pulse
24: Test Call = CT4 Timed
25: Batt Test = Disarm Timed
26: Bell = 2nd Alarm 1st Alarm
27: SNDR = 2nd Alarm 1st Alarm
28: Conf. = Delayed Instant
29: Abort = User Reset Eng.
30: Manual AV Output Auto