Trix H0 94.5 Series User manual

Modell der Tenderdampflokomotive Baureihe 94.5
22292
F
D GB USA NL

2

3
Inhaltsverzeichnis Seite
Sicherheitshinweise 4
Wichtige Hinweise 4
Multiprotokollbetrieb 4
Schaltbare Funktionen 7
Parameter/Register 8
Ergänzendes Zubehör 24
Wartung und Instandhaltung 28
Ersatzteile 34
Table of Contents Page
Safety Notes 9
Important Notes 9
Multi-Protocol Operation 9
Controllable Functions 12
Parameter/Register 13
Complementary accessories 24
Service and maintenance 28
Spare Parts 34
Sommaire Page
Remarques importantes sur la sécurité 14
Information importante 14
Mode multiprotocole 14
Fonctions commutables 17
Paramètre/Registre 18
Accessoires complémentaires 24
Entretien et maintien 28
Pièces de rechange 34
Inhoudsopgave Pagina
Veiligheidsvoorschriften 19
Belangrijke aanwijzing 19
Multiprotocolbedrijf 19
Schakelbare functies 22
Parameter/Register 23
Aanvullende toebehoren 24
Onderhoud en handhaving 28
Onderdelen 34

4
Sicherheitshinweise
• DieLokdarfnurmiteinemdafürbestimmtenBetriebssys-
tem eingesetzt werden.
• Analogmax.15Volt=,digitalmax.22Volt~.
• DieLokdarfnurauseinerLeistungsquelleversorgt
werden.
• BeachtenSieunbedingtdieSicherheitshinweiseinder
Bedienungsanleitung zu Ihrem Betriebssystem.
• FürdenkonventionellenBetriebderLokmussdasAn-
schlussgleisentstörtwerden.DazuistdasEntstörset
611655zuverwenden.FürDigitalbetriebistdasEntstör-
set nicht geeignet.
• ACHTUNG! Funktionsbedingte scharfe Kanten und Spitzen.
• SetzenSiedasModellkeinerdirektenSonneneinstrah-
lung,starkenTemperaturschwankungenoderhoher
Luftfeuchtigkeitaus.
• VerbauteLED`sentsprechenderLaserklasse1nach
Norm EN 60825-1.
Wichtige Hinweise
• DieBedienungsanleitungunddieVerpackungsind
BestandteiledesProduktesundmüssendeshalbaufbe-
wahrt sowie bei Weitergabe des Produktes mitgegeben
werden.
• FürReparaturenoderErsatzteilewendenSiesichbittean
IhrenTrix-Fachhändler.
• GewährleistungundGarantiegemäßderbeiliegenden
Garantieurkunde.
• Entsorgung:www.maerklin.com/en/imprint.html
• DervolleFunktionsumfangistnurunterDCCundunter
mfxverfügbar.
• Eingebaute,fahrtrichtungsabhängigeStirnbeleuchtung.
ImDigitalbetriebschaltbar.
• Rauchsatznachrüstbar-auchfürdenAnalogbetrieb.
• ImAnalogbetriebstehennurdieRauch-,Fahr-undLicht-
wechselfunktionenzurVerfügung.
• BefahrbarerMindestradius360mm.
Multiprotokollbetrieb
Analogbetrieb
DerDecoderkannauchaufanalogenAnlagenoderGleis-
abschnittenbetriebenwerden.DerDecodererkenntdie
analogeGleichspannung(DC)automatischundpasstsich
deranalogenGleisspannungan.EssindalleFunktionen,
dieuntermfxoderDCCfürdenAnalogbetriebeingestellt
wurdenaktiv(sieheDigitalbetrieb).
Digitalbetrieb
DerDecoderisteinMultiprotokolldecoder.DerDecoder
kannunterfolgendenDigital-Protokolleneingesetztwerden:
mfx,DCCoderMM.
AdresseabWerk:DCC 03 / MM 16
DasDigital-ProtokollmitdenmeistenMöglichkeitenistdas
höchstwertigeDigital-Protokoll.DieReihenfolgederDigital-
ProtokolleistinderWertungfallend:
Priorität1:mfx
Priorität2:DCC
Priorität3:MM

5
Hinweis: WerdenzweiodermehrereDigital-Protokolleam
Gleiserkannt,übernimmtderDecoderautomatischdas
höchstwertigeDigital-Protokoll;z.B.wirdmfx&DCCerkannt
wirddasmfx-Digital-ProtokollvomDecoderübernommen.
EinzelneProtokollekönnenüberdenParameterCV50
deaktiviert werden.
Hinweis:BeachtenSie,dassnichtalleFunktioneninallen
Digital-Protokollenmöglichsind.UntermfxundDCCkönnen
einigeEinstellungenvonFunktionen,welcheimAnalog-
Betriebwirksamseinsollen,vorgenommenwerden.
Hinweise zum Digitalbetrieb
• DiegenaueVorgehensweisezumEinstellenderdiversen
Parameter entnehmen Sie bitte der Bedienungsanleitung
Ihrer Mehrzug-Zentrale.
• DerBetriebmitgegenpoligerGleichspannungim
Bremsabschnitt ist mit der werkseitigen Einstellung
nichtmöglich.IstdieseEigenschaftgewünscht,somuss
aufdenkonventionellenGleichstrombetriebverzichtet
werden(CV29/Bit2=0).
mfx-Protokoll
Adressierung
• KeineAdresseerforderlich,jederDecodererhälteine
einmaligeundeindeutigeKennung(UID).
• DerDecodermeldetsichaneinerCentralStationoder
MobileStationmitseinerUIDautomatischan.
• NameabWerk:94 1036 DRG
Programmierung
• DieEigenschaftenkönnenüberdiegrascheOberäche
der Central Station bzw. teilweise auch mit der Mobile
Station programmiert werden.
• EskönnenalleCongurationVariablen(CV)mehrfach
gelesen und programmiert werden.
• DieProgrammierungkannentwederaufdemHaupt-oder
dem Programmiergleis erfolgen.
• DieDefaulteinstellungen(Werkseinstellungen)können
wieder hergestellt werden.
• Funktionsmapping:FunktionenkönnenmitHilfeder
CentralStation60212(eingeschränkt)undmitderCentral
Station 60213/60214/60215/60216/60226 beliebigen Funkti-
onstastenzugeordnetwerden(sieheHilfeinderCentral
Station).

6
DCC-Protokoll
Adressierung
• MöglicheAdressen:Kurze,langeundTraktionsadresse
• Adressbereich:
1–127(kurzeAdresse,Traktionsadresse)
1–10239(langeAdresse)
• JedeAdresseistmanuellprogrammierbar.
• KurzeoderlangeAdressewirdüberdieCVsausgewählt.
• EineangewandteTraktionsadressedeaktiviertdie
Standard-Adresse.
Programmierung
• DieEigenschaftenkönnenüberdieCongurationsVari-
ablen(CV)mehrfachgeändertwerden.
• DieCV-NummerunddieCV-Wertewerdendirekteinge-
geben.
• DieCVskönnenmehrfachgelesenundprogrammiert
werden(ProgrammierungaufdemProgrammiergleis).
• DieCVskönnenbeliebigprogrammiertwerden.PoM
(ProgrammierungaufdemHauptgleisPoM)istnurbei
den in der CV-Tabelle gekennzeichneten CV möglich.
PoMmussvonIhrerZentraleunterstütztwerden(siehe
BedienungsanleitungihresGerätes).
• DieDefaulteinstellungen(Werkseinstellungen)können
wieder hergestellt werden.
• 14bzw.28/126Fahrstufeneinstellbar.
• AlleFunktionenkönnenentsprechenddemFunktions-
mapping geschaltet werden.
• WeitereInformation,sieheCV-TabelleDCC-Protokoll.
Eswirdempfohlen,dieProgrammierungengrundsätzlichauf
dem Programmiergleis vorzunehmen.
Logische Funktionen
Anfahr-/Bremsverzögerung
• DieBeschleunigungs-undBremszeitkönnengetrennt
von einander eingestellt werden.
• DielogischeFunktionsabschaltungABVkannüberdas
Funktionsmapping auf jede beliebige Funktionstaste
gelegt werden.

7
Schaltbare Funktionen
DC/AC
MS I 1
MS II
CS I
CS II/III
Geräusch:Sandnachfüllen F18
Geräusch:Ankuppeln/Abkuppeln F19
Schaltbare Funktionen
DC/AC
MS I 1
MS II
CS I
CS II/III
Spitzensignal F0
Rauchgenerator 2F1
Betriebsgeräusch F2
Geräusch:Lokpfeifelang F3
ABV,aus F4
Geräusch:Bremsenquietschenaus F5
Geräusch:Luftpumpe F6
Geräusch:Rangierpff F7
Geräusch:Dampfablassen F8
Geräusch:Kohleschaufeln F9
Geräusch:Kipprost F10
Geräusch:Wasserpumpe F11
Geräusch:Injektor F12
Geräusch:Schienenstöße F13
Rangiergang + Rangierlicht doppel A F14
Geräusch:Sanden F15
Geräusch:Wassernachfüllen F16
Geräusch:Kohlefassen F17 1 TrixSystems
2 GehörtnichtzumLieferumfang.

8
CV Bedeutung Wert DCC ab Werk
1 Adresse 1 - 127 3
2 PoM Minimalgeschwindigkeit 0 - 255 4
3 PoM Anfahrverzögerung 0 - 255 28
4 PoM Bremsverzögerung 0 - 255 28
5 PoM Maximalgeschwindigkeit 0 - 255 150
8 Werkreset/Herstellerkennung 8 131
13 PoM Funktionen F1 - F8 im Analogbetrieb 0 - 255 0
14 PoM FunktionenF9-F15undLichtimAnalogbetrieb 0 - 255 1
17 ErweiterteAdresse(obererTeil) CV29,Bit5=1 192
18 ErweiterteAdresse(untererTeil) CV29,Bit5=1 128
19 Traktionsadresse 0 - 255 0
21 PoM Funktionen F1 - F8 bei Traktion 0 - 255 0
22 PoM FunktionenF9-F15undLichtbeiTraktion 0 - 255 0
29 PoM
Bit0:UmpolungFahrtrichtung
Bit1:AnzahlFahrstufen14oder28/128*
Bit2:DCCBetriebmitBremsstrecke(keinAnalogbetriebmöglich)
Bit5:kurze/langeAdresse
0 / 1
0 / 2
0 / 4
0 / 32
0,1,2,3,4,5,6,7,
32,34,35,36,37,
38,39 6
50 PoM
AlternativeProtokolle(DCCkannsichselbernichtdeaktivieren)
Bit0:AnalogACaus=0/AnalogACein=1
Bit1:AnalogDCaus=0/AnalogDCein=1
Bit2:fx(MM)aus=0/fx(MM)ein=1
Bit3:mfxaus=0/mfxein=1
0 / 1
0 / 2
0 / 4
0 / 8
0 - 15 15
63 PoM Lautstärke 0 - 255 255
* FahrstufenamLokdecoderundamSteuergerätmüssenübereinstimmen,essindsonstFehlfunktionenmöglich.

9
• ThefullrangeoffunctionsisonlyavailableunderDCC
andmfx.
• Built-inheadlightsthatchangeoverwiththedirectionof
travel. They can be turned on and off in digital operation.
• Asmokegeneratorcanberetrottedtothelocomotive-
also for analog operation.
• Onlythesmoke,running,andlightchangeoverfunctions
are available in analog operation.
• Minimumradiusforoperationis360mm/14-3/16“.
Multi-Protocol Operation
Analog Operation
This decoder can also be operated on analog layouts or ar-
eas of track that are analog. The decoder recognizes alter-
natingcurrent(DC)andautomaticallyadaptstotheanalog
trackvoltage.AllfunctionsthatweresetundermfxorDCC
foranalogoperationareactive(seeDigitalOperation).
Digital Operation
The decoders are multi-protocol decoders. These decoders
canbeusedunderthefollowingdigitalprotocols:mfx,DCC
or MM.
Addresssetatthefactory:DCC 03 / MM 16
The digital protocol with the most possibilities is the highest
order digital protocol. The sequence of digital protocols in
descendingorderis:
Priority1:mfx
Priority2:DCC
Priority3:MM
Safety Notes
• Thislocomotiveisonlytobeusedwiththeoperating
system it is designed for.
• Analogmax.15voltsDC,digitalmax.22voltsAC.
• Thislocomotivemustneverbesuppliedwithpowerfrom
more than one power pack.
• Pleasemakenoteofthesafetynotesintheinstructions
for your operating system.
• Thefeedertrackmustbeequippedtopreventinter-
ferencewithradioandtelevisionreception,whenthe
locomotive is to be run in conventional operation. The
611 655 interference suppression set is to be used for this
purpose. The interference suppression set is not suitable
for digital operation.
• WARNING! Sharp edges and points required for operation.
• Donotexposethemodeltodirectsunlight,extreme
changesintemperature,orhighhumidity.
• TheLEDsinthisitemcorrespondtoLaserClass1accor-
ding to Standard EN 60825-1.
Important Notes
• Theoperatinginstructionsandthepackagingareacom-
ponent part of the product and must therefore be kept as
well as transferred along with the product to others.
• PleaseseeyourauthorizedTrixdealerforrepairsor
spare parts.
• Thewarrantycardincludedwiththisproductspecies
the warranty conditions.
• Disposing:www.maerklin.com/en/imprint.html

10
Note: If two or more digital protocols are recognized in the
track,thedecoderautomaticallytakesonthehighestvalue
digitalprotocol.Forexample,ifmfx&DCCarerecognized,
themfxdigitalprotocolistakenonbythedecoder.Individual
protocols can be deactivated with Parameter CV 50.
Note: Please note that not all functions are possible in all
digitalprotocols.Severalsettingsforfunctions,whichare
supposedtobeactiveinanalogoperation,canbedone
undermfxandDCC.
Notes on digital operation
• Theoperatinginstructionsforyourcentralunitwillgive
youexactproceduresforsettingthedifferentparame-
ters.
• Thesettingdoneatthefactorydoesnotpermitoperation
withoppositepolarityDCpowerinthebrakingblock.
Ifyouwantthischaracteristic,youmustdowithout
conventionalDCpoweroperation(CV29/Bit2=0).
mfx Protocol
Addresses
• Noaddressisrequired;eachdecoderisgivenaone-
time,uniqueidentier(UID).
• ThedecoderautomaticallyregistersitselfonaCentral
StationoraMobileStationwithitsUID.
• Namesetatthefactory:94 1036 DRG
Programming
• Thecharacteristicscanbeprogrammedusingthe
graphic screen on the Central Station or also partially
with the Mobile Station.
• AlloftheCongurationVariables(CV)canbereadand
programmed repeatedly.
• Theprogrammingcanbedoneeitheronthemaintrackor
the programming track.
• Thedefaultsettings(factorysettings)canbeproduced
repeatedly.
• Functionmapping:Functionscanbeassignedto
any of the function buttons with the help of the
60212CentralStation(withlimitations)andwiththe
60213/60214/60215/60216/60226CentralStation(Seehelp
sectionintheCentralStation).

11
DCC Protocol
Addresses
• Possibleaddresses:short,long,andm.u.address
• Addressrange:
1–127(shortaddress,m.u.address)
1–10239(longaddress)
• Everyaddresscanbeprogrammedmanually.
• AshortoralongaddressisselectedusingtheCVs.
• Amultipleunitaddressthatisbeinguseddeactivatesthe
standard address.
Programming
• Thecharacteristicscanbechangedrepeatedlyusingthe
CongurationVariables(CV).
• TheCVnumbersandtheCVvaluesareentereddirectly.
• TheCVscanbereadandprogrammedrepeatedly.(Pro-
grammingisdoneontheprogrammingtrack.)
• TheCVscanbeprogrammed,asyoudesire.PoM(Pro-
grammingonthelayouttrack)isonlypossiblewiththose
CVs marked in the CV table. PoM must be supported
byyourcentralcontroller(seetheinstructionsforyour
controller).
• Thedefaultsettings(factorysettings)canbeproduced
repeatedly.
• 14or28/126speedlevelscanbeset.
• Allofthefunctionscanbecontrolledaccordingtothe
functionmapping(seeCVdescription).
• SeetheCVdescriptionfortheDCCprotocolforadditional
information.
We recommend that in general programming should be
done on the programming track.
Logic Functions
Acceleration / Braking Delay
• Theaccelerationandbrakingtimescanbesetseparately
from each other.
• ThelogicalfunctionshutoffforABV(Acceleration/
BrakingDelay)canbeassignedtoanyfunctionbuttonby
means of function mapping.

12
Controllable Functions
DC/AC
MS I 1
MS II
CS I
CS II/III
Soundeffect:Fillingsand F18
Soundeffect:Coupling/uncoupling F19
Controllable Functions
DC/AC
MS I 1
MS II
CS I
CS II/III
Headlights F0
Smoke generator 2F1
Operating sounds F2
Soundeffect:Longlocomotivewhistle F3
ABV,off F4
Soundeffect:Squealingbrakesoff F5
Soundeffect:Airpump F6
Soundeffect:Switchingwhistle F7
Soundeffect:Blowingoffsteam F8
Soundeffect:Coalbeingshoveled F9
Soundeffect:Ashgrate F10
Soundeffect:Waterpump F11
Soundeffect:Injector F12
Soundeffect:Railjoints F13
Lowspeedswitchingrange+
DoubleAswitchinglight F14
Soundeffect:Sanding F15
Soundeffect:ReplenishWater F16
Soundeffect:Fillingcoal F17 1 TrixSystems
2Not included in delivery scope.

13
* Thespeedlevelsonthelocomotivedecoderandonthecontrollermustagreewitheachother;otherwise,
you may have malfunctions.
CV Discription DCC Value Factory-Set
1 Address 1 - 127 3
2 PoM Minimum Speed 0 - 255 4
3 PoM Acceleration delay 0 - 255 28
4 PoM Braking delay 0 - 255 28
5 PoM Maximumspeed 0 - 255 150
8 Factory Reset / Manufacturer Recognition 8 131
13 PoM Functions F1 - F8 in analog operation 0 - 255 0
14 PoM Functions F9 - F15 and lights in analog operation 0 - 255 1
17 Extendedaddress(upperpart) CV29,Bit5=1 192
18 Extendedaddress(lowerpart) CV29,Bit5=1 128
19 MultipleUnitAddress 0 - 255 0
21 PoM FunctionsF1-F8onMultipleUnit 0 - 255 0
22 PoM FunctionsF9-F15andlightsonMultipleUnit 0 - 255 0
29 PoM
Bit0:Reversingdirectionoftravel
Bit1:Numberofspeedlevels14or28/128*
Bit2:DCCoperationwithabrakingarea(noanalogoperation
possible)
Bit5:short/longaddress
0 / 1
0 / 2
0 / 4
0 / 32
0,1,2,3,4,5,6,
7,32,34,35,36,
37,38,39 6
50 PoM
AlternativeProtocols(DCCcannotdeactivateitself)
Bit0:AnalogACoff=0/AnalogACon=1
Bit1:AnalogDCoff=0/AnalogDCon=1
Bit2:fx(MM)off=0/fx(MM)on=1
Bit3:mfxoff=0/mfxon=1
0 / 1
0 / 2
0 / 4
0 / 8
0 - 15 15
63 PoM Volume 0 - 255 255

14
Remarques importantes sur la sécurité
• Lalocomotivenepeutêtreutiliséequ‘aveclesystème
d‘exploitationindiqué.
• Analogiquemax.15Volt=,digitalmax.22Volt~.
• Lalocomotivenepeutpasêtrealimentéeélectriquement
parplusd‘unesourcedecourantàlafois.
• Ilestimpératifdetenircomptedesremarquessurla
sécuritédécritesdanslemoded‘emploidevotresystème
d‘exploitation.
•
Pourl’exploitationdelalocomotiveenmodeconvention-
nel,lavoiederaccordementdoitêtredéparasitée.Acet
effet,utiliserlesetdedéparasitageréf.611655.Lesetde
déparasitageneconvientpaspourl’exploitationenmode
numérique.
•
ATTENTION! Pointes et bords coupants lors du fonctionne-
ment du produit.
• Nepasexposerlemodèleàunensoleillementdirect,
àdefortesvariationsdetempératureouàuntaux
d‘humiditéimportant.
• LesDELinstalléescorrespondentàlaclasselaser1
selon la norme EN 60825-1.
Information importante
• Lanoticed‘utilisationetl’emballagefontpartieintégrante
duproduit;ilsdoiventdoncêtreconservéset,lecas
échéant,transmisavecleproduit.
• Pourtouteréparationouremplacementdepièces,adres-
sezvousàvotredétaillant-spécialisteTrix.
• Garantielégaleetgarantiecontractuelleconformément
aucerticatdegarantieci-joint.
• Elimination:www.maerklin.com/en/imprint.html
• L’intégralitédesfonctionsestdisponibleuniquementen
exploitationDCCetmfx.
• Feuxdesignalisations‘inversantselonlesensdemar-
che;feuxcommutablesenexploitationdigital.
• Installationultérieured’ungénérateurdefuméepossible
-égalementpourexploitationanalogique.
•
Enmoded’exploitationanalogique,seuleslesfonctions
relativesàlafumée,laconduiteetl’inversiondesfeuxsont
disponibles.
• Rayonminimald’inscriptionencourbe360mm.
Mode multiprotocole
Mode analogique
On peut aussi faire fonctionner le décodeur sur des instal-
lationsoudessectionsdevoieanalogiques.Ledécodeur
identieautomatiquementlatensiondevoieanalogique
(DC).Touteslesfonctionsquiontétéparamétréepourle
modeanalogiquesousmfxousousDCCsontactives(voir
modenumérique).
Mode numérique
Lesdécodeursontdesdécodeurmultiprotocole.Le
décodeurpeutêtreutiliséaveclesprotocolesnumériques
suivants:mfx,DCC,MM
Adresseencodéeenusine:DCC 03 / MM 16

15
Leprotocolenumériqueoffrantlespossibilitéslesplus
nombreusesestleprotocolenumériqueàbitdepoids
fort.Lahiérarchisationdesprotocolesnumériquesest
descendante:
Priorité1:mfx
Priorité2:DCC
Priorité3:MM
Indication :Sideuxouplusdedeuxprotocolesnumériques
sontreconnussurlavoie,ledécodeurchoisitautomatique-
mentleprotocolenumériqueleplussignicatif.Entreles
protocolesmfx&DCCparexemple,ledécodeurchoisira
leprotocolenumériquemfx.Vouspouvezdésactiverles
différents protocoles via le paramètre CV 50.
Indication : remarquez que toutes les fonctions ne peuvent
pasêtreactionnéesdanstouslesprotocolesnumériques.
SousmfxetsousDCC,ilestpossibledeprocéderà
quelquesparamétragesdefonctionsdevantêtreactives
danslecadredel’exploitationanalogique.
Remarques relatives au fonctionnement en mode digital
• Encequiconcernelaprocédurederéglagedesdivers
paramètres,veuillezvousréféreraumoded‘emploide
votre centrale de commande multitrain.
• L’exploitationaveccourantcontinudepolaritéinverse
dans les sections de freinage n’est pas possible avec
leréglaged’usine.Sicettepropriétéestdésirée,ilfaut
alorsrenonceràl’exploitationconventionnelleencou-
rantcontinu(CV29/Bit2=0).
Protocole mfx
Adressage
• Aucuneadressen’estnécessaire,ledécodeurreçoittou-
tefoisuneidenticationuniqueetnonéquivoque(UID).
• AvecsonUID,ledécodeurindiqueautomatiquement
àunestationcentraleouàunestationmobilequ’ilest
connecté.
• Nomencodeeenusine:94 1036 DRG
Programmation
• Lescaractéristiquespeuventêtreprogramméespar
l’intermédiaire de la couche graphique de la station cen-
trale,voireenpartieaussiaumoyendelastationmobile.
• Touteslescongurationsvariables(CV)peuventêtrelues
etprogramméesdefaçonréitérée.
• Laprogrammationpeutêtreréaliséesoitsurlavoie
principale,soitsurlavoiedeprogrammation.
• Lesparamétragespardéfaut(paramétragesusine)
peuventêtrerétablis.
• Mappagedesfonctions:lesfonctionspeuventêtre
affectéesàdequelconquestouchesdefonctionau
moyendelastationcentrale(60212)(restreinte)etavec
lastationcentrale60213/60214/60215/60216/60226(voir
Aideauniveaudelastationcentrale).

16
Protocole DCC
Adressage
• Adressepossibles:Courtes,longuesetadressesdetraction
• Catégoried’adresse:
1à127(adressescourtes,adressesdetraction)
1à10239(adresseslongues)
• Chaqueadresseestprogrammablemanuellement.
• L’adressebrèveoulongueestchoisieparl’intermédiaire
des CVs.
• Uneadressedetractionutiliséedésactivel’adresse
standard.
Programmation
• Lescaractéristiquespeuventêtremodiéesdefaçon
réitéréeparl’intermédiairedesvariablesdeconguration
(CVs).
• Touteslescongurationsvariables(CV)peuventêtrelues
etprogramméesdefaçonréitérée.
• Laprogrammationpeutêtreréaliséesoitsurlavoie
principale,soitsurlavoiedeprogrammation.
• LesCVpeuventêtreprogramméeslibrement.LaPoM
(programmationsurlavoieprincipale)estpossible
uniquement pour les CV signalées dans le tableau des CV.
LaPoMdoitêtrepriseenchargeparvotrecentrale(voir
lanoticed’utilisationdevotreappareil).
• Lesparamétragespardéfaut(paramétragesusine)
peuventêtrerétablis.
• 14voire28/126cransdemarchesontparamétrables.
• Touteslesfonctionspeuventêtrecommutéesenfonction
dumappagedesfonctions(voirledescriptifdesCVs).
• Pourtouteinformationcomplémentaire,voirletableau
desCVs,protocoleDCC.
Ilestrecommandé,deréaliserlaprogrammation,fonda-
mentalement,surlavoiedeprogrammation.
Fonctions logiques
Temporisation d’accélération et de freinage (TAF)
• Lestempsd’accélérationetdefreinagepeuventêtre
dénisindépendammentl’undel’autre.
• LadésactivationdelafonctionlogiqueTAFpeutêtre
affectéeàn’importequelletouchedefonctionviale
mappage de fonctions.

17
Fonctions commutables
DC/AC
MS I 1
MS II
CS I
CS II/III
Bruitage:Approvisionnementensable F18
Bruitage:Attelage/Déconnecter F19
Fonctions commutables
DC/AC
MS I 1
MS II
CS I
CS II/III
Fanal F0
Générateurdefumée2F1
Bruitd’exploitation F2
Bruitage:Sifetlocomotivelong F3
ABV,désactivé F4
Bruitage:Grincementdefreinsdésactivé F5
Bruitage:Compresseur F6
Bruitage:Sifetpourmanœuvre F7
Bruitage:Échappementdelavapeur F8
Bruitage:Pelletageducharbon F9
Bruitage:Grillebasculante F10
Bruitage:Pompeàeau F11
Bruitage:Injecteur F12
Bruitage:jointsderail F13
Vitesse de manoeuvre +
Feu de manoeuvre double A F14
Bruitage:Sablage F15
Bruitage:Eau,remiseàniveau F16
Bruitage:Approvisionnementencharbon F17 1 TrixSystems
2Ne fait pas partie de la fourniture.

18
CV Affectation DCC Valeur Parm. Usine
1 Adresse 1 - 127 3
2 PoM Vitesse minimale 0 - 255 4
3 PoM Temporisationd‘accélération 0 - 255 28
4 PoM Temporisation de freinage 0 - 255 28
5 PoM Vitessemaximale 0 - 255 150
8Réinitialisationd’usine/identicationdufabricant 8 131
13 PoM Fonctions F1 - F8 en mode analogique 0 - 255 0
14 PoM Fonctions F9 - F15 et éclairage en mode analogique 0 - 255 1
17 Adresseétendue(partiesupérieure) CV29,Bit5=1 192
18 Adresseétendue(partieinférieure) CV29,Bit5=1 128
19 Adresse traction 0 - 255 0
21 PoM Fonctions F1 - F8 pour traction 0 - 255 0
22 PoM Fonctions F9 - F15 et éclairage traction 0 - 255 0
29 PoM
Bit0:Inversiondusensdemarche
Bit1:Nombredecransdemarche14ou28/128*
Bit2:ExploitationDCCavecsectiondefreinage(exploitation
analogiqueimpossible)
Bit5:Adressecourte/longue
0 / 1
0 / 2
0 / 4
0 / 32
0,1,2,3,4,5,6,
7,32,34,35,36,
37,38,39 6
50 PoM
Autresprotocoles(DCCnepeutpassedésactiverlui-même)
Bit0:AnalogiqueCAhorsfonction=0/analogiqueCAenfonction=1
Bit1:AnalogiqueCChorsfonction=0/analogiqueCCenfonction=1
Bit2:fx(MM)horsfonction=0/fx(MM)enfonction=1
Bit3:mfxhorsfonction=0/mfxenfonction=1
0 / 1
0 / 2
0 / 4
0 / 8
0 - 15 15
63 PoM Volume 0 - 255 255
* Pourévitertoutdysfonctionnement,lescransdemarchesurledécodeurdelocodoiventimpérativement
coïncideravecceuxdel’appareildecommande.

19
Veiligheidsvoorschriften
• Delocmagalleenmeteendaarvoorbestemdbedrijfssys-
teem gebruikt worden.
• Analoogmax.15Volt=,digitaalmax.22Volt~.
• Delocmagnietvanuitmeerdanéénstroomvoorziening
gelijktijdig gevoed worden.
• Leesookaandachtigdeveiligheidsvoorschrifteninde
gebruiksaanwijzing van uw bedrijfssysteem.
• Voorhetconventionelebedrijfmetdelocdientde
aansluitrail te worden ontstoort. Hiervoor dient men de
ontstoor-set 611 655 te gebruiken. Voor het digitale bedrijf
is deze ontstoor-set niet geschikt.
• OPGEPAST! Functionele scherpe kanten en punten.
• Stelhetmodelnietblootaanindirectezonnestraling,
sterke temperatuurwisselingen of hoge luchtvochtigheid.
• IngebouwdeLED’skomenovereenmetdelaserklasse1
volgens de norm EN 60825-1.
Belangrijke aanwijzing
• Degebruiksaanwijzingendeverpakkingzijneenbe-
standdeel van het product en dienen derhalve bewaard
en meegeleverd te worden bij het doorgeven van het
product.
• VoorreparatiesenonderdelenkuntzichtotUwTrix
handelaar wenden.
• Vrijwaringengarantieovereenkomstighetbijgevoegde
garantiebewijs.
• Afdanken:www.maerklin.com/en/imprint.html
• Devolledigetoegangtotallefunctiesisalleenmogelijk
metDCCofmetmfxbedrijf.
• Ingebouwde,rijrichtingsafhankelijkefrontverlichtingisin
het digitaalsysteem schakelbaar.
• Rookgeneratornadienintebouwen-ookvooranaloog
bedrijf.
• Inanaloogbedrijfzijnalleenroken-,rijden,enlichtwisse-
ling als functie beschikbaar.
• Minimaleteberijdenradius:360mm.
Multiprotocolbedrijf
Analoogbedrijf
Dedecoderkanookopanalogemodelbanenofspoortra-
jectengebruiktworden.Dedecoderherkentdeanaloge
gelijkspanning(DC)automatischenpastzichaande
analogerailspanningaan.AllefunctiesdieondermfxofDCC
voorhetanalogebedrijfzijningesteld,wordengeactiveerd
(ziedigitaalbedrijf).
Digitaalbedrijf
DeDecoderiseenmultiprotocoldecoder.Dedecoderkan
onderdevolgendedigitaleprotocolleningezetworden:mfx,
DCC,MM.
Vanafdefabriekingesteld:DCC 03 / MM 16
Het digitaalprotocol met de meeste mogelijkheden is het
primairedigitaalprotocol.Devolgordevandedigitaalproto-
collenisafnemendinmogelijkheden:
Prioriteit1:mfx
Prioriteit2:DCC
Prioriteit3:MM

20
Opmerking: Als er twee of meer digitale protocollen op
derailswordenherkend,danneemtdedecoderautoma-
tischhethoogwaardigsteprotocolover;bijv.wordmfx&
DCCherkend,danwordthetmfxsignaaldoordedecoder
overgenomen.Deverschillendeprotocollenkunnenviade
parameter CV 50 gedeactiveerd worden.
Opmerking: let er op dat niet alle functies in alle digitaal-
protocollenmogelijkzijn.OndermfxofDCCkunnenenkele
instellingen,welkeinanaloogbedrijfwerkzaammoetenzijn,
ingesteld worden.
Aanwijzingen voor digitale besturing
• Hetopdejuistewijzeinstellenvandediverseparame-
ters staat beschreven in de handleiding van uw digitale
Centrale.
• Hetbedrijfmettegengepooldegelijkspanningindeafrem-
sectie is met de fabrieksinstelling niet mogelijk. Indien deze
eigenschapwenselijkis,danmoetwordenafgezienvan
hetconventioneelgelijkstroombedrijf(CV29/Bit2=0).
mfx-protocol
Adressering
• Eenadresisnietnodig,elkedecoderheefteenéénmalig
enéénduidigkenmerk(UID).
• DedecodermeldtzichvanzelfaanbijhetCentralStation
ofMobileStationmetzijnUID.
• Naamafdefabriek:94 1036 DRG
Programmering
• Deeigenschappenkunnenm.b.v.hetgraschescherm
op het Central Station resp. deels ook met het Mobile
Station geprogrammeerd worden.
• Alleconguratievariabelen(CV)kunnenvakergelezen
en geprogrammeerd worden.
• Deprogrammeringkanzowelophethoofdspooralsop
het programmeerspoor gebeuren.
• Dedefault-instellingen(fabrieksinstelling)kunnenweer
hersteld worden.
• Functiemapping:functieskunnenmetbehulpvanhet
CentralStation60212(metbeperking)enmethet
Central Station 60213/60214/60215/60216/60226 aan elke
gewenstefunctietoetswordentoegewezen(ziehet
helpbestandinhetCentralStation).
This manual suits for next models
1
Table of contents
Languages:
Other Trix Toy manuals

Trix
Trix H0 BR 96 User manual

Trix
Trix H0 Bauart G User manual

Trix
Trix PtL 2/2 User manual

Trix
Trix VT 04.5 User manual

Trix
Trix E 18 BBO User manual

Trix
Trix KOF II User manual

Trix
Trix BR98.3 User manual

Trix
Trix Minitrix BR 44 User manual

Trix
Trix E-Lok Ae 8/14 User manual

Trix
Trix Minitrix 66304 User manual