UWE CSB-3T User manual


1
CONTENT
1CAUTION 2
2INSTALLATION INSTRUCTIONS 4
3SPECIFICATIONS 6
4KEYBOARD LAYOUT 8
5KEYS AND INDICATORS 9
6INTERNAL FUNCTIONS 12
7OPERATING INSTRUCTIONS 14
8TROUBLESHOOTING 19
9WARRANTY 23
10 DAILY CARE AND MAINTENANCE 24

2
1. Never attempt to open this scale, no user
serviceable parts inside.
2. Remove all loads from hook when not in use.
3. Do not remove the wire rope stopper. For
safety reasons, always apply it.
4. Before weighing, check and make sure that
all hanging /load- receiving elements/
devices are in good condition. And please
replace the necessary component regularly.
5. Crane scale is only suitable for hanging
from a mechanical hook, e.g. a crane hook.
Check whether the used crane hook or the
lifting device is suitable for the suspended
load.
6. Make sure that there are no persons or
objects under the load; secure Working Area
to prevent any possible injury or damage.
7. The scale is not suitable for weighing a
person.
8. Load the scale only in vertical traction
direction.
9. Always avoid vibration and horizontal

3
force.
10.Prevent jolts, torsion and oscillation (e.g.
by sloping appending) of all kinds. Be sure
to prevent overloading the scales (Stated
Maximum Load Object Weight + Tare Weight).
Overload could damage the scale (risk of
breakage). Do not use the crane scale to
transport loads (e.g. traveling crane).
11.Never operate the scale in hazardous
locations. The series design is not
explosion-proof.
12.Any structural alterations should not be
made to the scale. This will lead to
incorrect weighing result, to violation of
safety regulations and to destruction of
the scale.
13.Avoid sudden and jerky acceleration or
deceleration of the load (risk of breakage).
Please always follow the instruction.

4
INSTALLATION INSTRUCTIONS
2.1 UNPACK this scale very carefully. Check
and make sure that the following items are
included:
a. This operation manual
b. CSB series scale x 1 (one Power Pack
installed)
c. AC adaptor x 1
d. Wireless remote control x 1 (optional)
e. Additional Power pack x 1 (optional)
Contact your dealer if any item is missing.
2.2 SECURING THE SCALE
2.2.1 This unit must be hanged via a strong
media, e.g. a wire rope or a metal hook, to
a firm support that can withstands at least
5 times of scale capacity.
2.2.2 Make sure that the crane scale is hanged
vertically.
2.3 POWERING THE SCALE
a. This scale is powered by the built-in
rechargeable Power Pack and/or by an AC

5
adapter. An additional Power Pack is
available as option.
b. Check and make sure that the voltage of the
AC adaptor supplied matches with the voltage
of the main output.
c. Insert the output plug of AC adaptor firmly
into the DC input jack of scale. The DC input
jack is located underneath the back of the
scale.
d. Before the first time use, charge the
rechargeable Power Pack for at least 8 hours
consecutively or until the charging
indicator turns green.
e. For safety reasons, do not share the same
mains outlet with other apparatus.
2.4 OPTIMAL INSTALLATION REQUIREMENTS
For optimal results, it is recommended that
this product should be installed in a location
free from corrosive gas, dust, and electronic
interference.

6
SPECIFICATIONS
Model No.
Capacity
Division
Test
Ultimate
Overload
Net
Weight
CSB-3T
3000kg/6600lb
1kg/2lb
300% of
R.C.
13.6kg
CSB-5T
5000kg/11000lb
2kg/5lb
300% of
R.C.
19.5kg
CSB-7.5T
7500kg/16000lb
5kg/10lb
300% of
R.C.
29.6kg
CSB-10T
10000kg/20000lb
5kg/10lb
300% of
R.C.
29.6kg
CSB-15T
15000kg/30000lb
5kg/10lb
300% of
R.C.
73.1kg
CSB-20T
20000kg/40000lb
10kg/20lb
300% of
R.C.
73.1kg
Power
Source
By Built-in Rechargeable Power Pack and/or,
DC12~15V,500mA or 1A.
Hook Type
Fixed type for CSB models and Wire Rope
Stopper Included
Tare Range
Full Range
Zero Range
Maximum = 2% of Rated Capacity
Options
Wireless or Cable Remote Control,
Optional Power Pack (24 Hours Non-stop
Operation)
*To comply with the law of certain countries, the pound unit may be
disabled. AC Adaptor might differ from country to country.
Specifications and functions subject to change without prior notice.

7
DIMENSIONS FOR CSB (mm)
DIMENSIONS (mm):
Model
Cap.
A
B
C
D
E
F
G
H
HOOK
CSB-3T
211
118
181
183
58
36
50
264
6.5T
CSB-5T
211
164
181
188
72
43
60
274
9.5T
CSB-7.5T
211
254
181
255
90
48
70
298
13.5T
CSB-10T
211
254
181
255
90
48
70
298
13.5T
CSB-15T
211
361
181
462
150
88
95
304
35T
CSB-20T
211
361
181
462
150
88
95
304
35T
A
BCD
E
F
G
H

8
KEYBOARD LAYOUT
CSB

9
KEYS AND INDICATORS
1. POWER ON/OFF KEY
Press this key to turn scale on/off.
2. HOLD KEY
Press this key to hold/release the current
weight being displayed/held.
3. MODE KEY
Press this key to switch between measurement
units, or to convert a weight reading into the
other unit of measurement. (In Metric System
Countries, this key will be without any
function.)
4. TARE KEY
Press this key to tare off the weight of a
container or decrease value during function
setting.
5. ZERO KEY
Press this key to set weight to zero, or increase
value during function setting.

10
6. ZERO INDICATOR
When the weight detected is at true zero, ZERO
indication will appear (ON).
7. TARE INDICATOR
When the tare function is being employed, a
TARE indication will appear (ON).
8. METRIC INDICATOR
When this indicator is on, the metric weight
unit is being employed.
9. POUND INDICATOR
When this indicator is on, the pound weight
unit is being employed. (This indicator may
not be available in certain countries).
KEYS ON REMOTE CONTROL (OPTION)
10. ZERO KEY
Press this key to set weight to zero (max. zero
range = 2% of rated capacity).
11. TARE KEY

11
Press this key to tare off the weight of a
container.
12. MODE KEY
Press this key to shift between weight units.
13. HOLD KEY
Press this key to hold/release the current
weight being displayed/ held.

12
INTERNAL FUNCTIONS
6.1 INTERNAL FUNCTION TABLE
Function
Symbol
Description
NOTE
1
Fun-1
Scale configuration
setting and dealer
Calibration.
**
2
Fun-2
Display segment
check.
3
Fun-3
Offset value and span
value reading.
**
4
Fun-4
Auto power off
setting
NOTE **:
For dealer and authorized personnel only.
Inappropriate setting(s) will cause system
failure. Contact your dealer for more
information or service.
6.2 HOW TO ENTER THE REQUIRED FUNCTION MODE
a. Turn scale off.
b. Press and hold TARE, then turn scale on.
Scale displays Fun-1
c. Press TARE until the required function
number appears.
d. Press MODE

13
e. Press MODE until the required setting
appears.
f. Press TARE to confirm.
g. Repeat step c to f for other function setting,
or
h. Press ZERO to save settings and return to
normal operation.
6.3 INTERNAL FUNCTIONS DESCRIPTION
Fun-1 Contact your dealer for more
information.
Fun-2 To check all display segments work
properly.
Fun-3 Contact your dealer for more
information.
Fun-4 To set Auto Power Off Function.
Two modes are available: (Default =
4_OFF)
0._OFF = Auto Power Off Function is
disabled.
4._OFF = Scale will automatically
turned off after 4 minutes
unused.

14
OPERATING INSTRUCTIONS
8.1 PLACING THE SCALE
Hang this scale with a strong enough media where
is free from RF interference, vibration, fire,
direct sunlight and excessive moisture.
For safety reasons and best weighing result,
always hang this scale and lift a load
vertically.
8.2 POWER ON/OFF THE SCALE
Press ON to turn scale on.
Press OFF to turn scale off.
8.3 ZERO FUNCTION
If ZERO INDICATOR does not appear when scale
is unloaded, press ZERO to reset weight
displayed to zero. Refer to general
specification table for maximum zero range.
8.4 TARE FUNCTION
8.4.1 To Tare Off the Weight of a Container
Apply a container to hook, then press TARE
to tare off the weight of it. After the TARE
is pressed, the TARE INDICATOR appears.

15
8.4.2 To Clear the Weight of a Container
from memory
Remove the container from hook then press
TARE. The tare indicator will go off
indicating no container weight is resided
in memory.
8.5 PLACING A LOAD
Always apply a load to hook gently. Sudden shock,
excessive force or overloading the scale may
cause damage to the weight sensor inside.
It is a good practice to remove all loads from
hook when not in use.
This would prolong the lifetime of weight
sensor.
8.6 WEIGHING FUNCTION
a. Before weighing, make sure that the Zero
Status Sign is on.
b. Press MODE until the required weight unit
appears.
c. Apply subject matter to hook and the weight
of it is displayed.
d. For best weighing result, refer to general
specification table for recommended
minimum weight to be applied.

16
8.7 HOLDING THE WEIGHT BEING DISPLAYED
a. Press HOLD to hold the weight being display.
For accuracy considerations, only press
HOLD when weight is stable.
b. After HOLD is pressed, the flashing weight
value appears.
c. To release weight value being held, press
HOLD again.
8.8 AUTO-HOLD FUNCTION
This function provides a smart way to reduce
the waiting time for stable weighting.
While the weight is placed on the hook, an
average weight value will be calculated and
held on the display for few seconds depending
on the Auto-Hold Time Period setting.
Auto-Hold Time Period setting:
1. Press HOLD key for about 2 seconds, the
display will read “Hod._0”
2. Press the HOLD key to increase the time
period for 3, 5, 8, 10, 12, 15, 17, 20
(sec.) in sequence.
3. Choose the time period, then wait for
about 5 sec., it will be switched back
to normal operation automatically.

17
8.9 SHIFT BETWEEN DIFFERENT WEIGHT UNITS
Press MODE to shift different weight units.
NOTE: The pound unit may not be available in
certain countries.
8.10 SWITCHING BACKLIGHT ON/OFF
Method 1: During operating process, the
backlight can be switched ON/OFF by
pressing the MODE key to shift to the desired
status.
Method 2: When unloaded (weight=0), press
and hold the ON/ZERO key for about 2
seconds to set backlight ON/OFF.
8.11 RECHARGING THE SCALE
8.11.1 When low battery signal appears,
insert a charged Power Pack or apply the
AC adaptor to recharge the inserted Power
Pack. Failure in doing so may cause
irrecoverable damage to the rechargeable
Power Pack.
8.11.2 Low battery signal is represented
by either case of the follows depends on
operating status.
8.11.2.1 Low battery is detected when power

18
on
Scale shows LOBAT after self-test down
count but displaying zero weight.
8.11.2.2 Low battery is detected during
operation
Weight display flashes once every 5
seconds.
8.12 REMOTE CONTROL
a. Pressing the corresponding key on the remote
control can attain same control results.
NOTE: All internal function settings can only
be operated through scale panel keys.
b. Operation distance from CSB scale to
wireless remote control is 10 meters
unobstructed.
c. When remote control distance decreases,
change the battery located inside the
wireless remote control.
d. Unique radio frequency is assigned to
specified unit. Never change DIP switch
setting of the wireless remote control.

19
TROUBLESHOOTING
SCALE CANNOT BE TURNED ON
CHECK: Is the rechargeable Power Pack
properly charged and plugged?
ACTION: Reexamine the Power Pack and make
sure that the Power Pack is
charged (8 hour charging time is
recommended during first time
use).
ZERO WEIGHT CANNOT BE ATTAINED WHEN TURNED ON
CHECK: Is the scale hanged vertically?
ACTION: Check and try again.
CHECK: Is any load applied to the hook?
ACTION: Remove all loads from hook. Turn
scale off and turn on again.
CHECK: Is the scale affected by airflow,
vibration or RF interference?
ACTION: Place scale away from all
disturbances and try again.
This manual suits for next models
5
Table of contents
Other UWE Scale manuals
Popular Scale manuals by other brands

Steinberg Systems
Steinberg Systems SBS-PW-402C user guide

Scarlett
Scarlett SC-1211 instruction manual

Hema
Hema 80301514 Instructions for use

Vishay Precision Group
Vishay Precision Group VPG On-Board Weighing SI Onboard TruckWeigh Installation, Setup and Calibration Manual

Detecto
Detecto VET330WH owner's manual

Steinberg
Steinberg SBS-PT-30000 user manual