manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Viega
  6. •
  7. Plumbing Product
  8. •
  9. Viega 2842.5 User manual

Viega 2842.5 User manual

Other Viega Plumbing Product manuals

Viega 8142 User manual

Viega

Viega 8142 User manual

Viega Eco Plus 8130.2 User manual

Viega

Viega Eco Plus 8130.2 User manual

Viega Prevista Dry Plus 8570.35 User manual

Viega

Viega Prevista Dry Plus 8570.35 User manual

Viega Prevista Dry Plus 8545.32 User manual

Viega

Viega Prevista Dry Plus 8545.32 User manual

Viega Simplex 6168.46 User manual

Viega

Viega Simplex 6168.46 User manual

Viega 6161.50 User manual

Viega

Viega 6161.50 User manual

Viega Eco Plus User manual

Viega

Viega Eco Plus User manual

Viega Prevista Pure 8512 User manual

Viega

Viega Prevista Pure 8512 User manual

Viega Prevista Dry 8573 User manual

Viega

Viega Prevista Dry 8573 User manual

Viega Eco Plus User manual

Viega

Viega Eco Plus User manual

Viega Multiplex Trio Visign MT3 User manual

Viega

Viega Multiplex Trio Visign MT3 User manual

Viega 8624.1 User manual

Viega

Viega 8624.1 User manual

Viega 4987.2 User manual

Viega

Viega 4987.2 User manual

Viega Prevista Dry 8535.32 User manual

Viega

Viega Prevista Dry 8535.32 User manual

Viega 6142.33 User manual

Viega

Viega 6142.33 User manual

Viega Grundfix Plus User manual

Viega

Viega Grundfix Plus User manual

Viega 8317 User manual

Viega

Viega 8317 User manual

Viega 8655.11 User manual

Viega

Viega 8655.11 User manual

Viega 8570 User manual

Viega

Viega 8570 User manual

Viega PureFlow Press Zero Lead Instruction sheet

Viega

Viega PureFlow Press Zero Lead Instruction sheet

Viega 4921.4 User manual

Viega

Viega 4921.4 User manual

Viega 8351.1 User manual

Viega

Viega 8351.1 User manual

Viega Prevista Dry Plus 8545.31 User manual

Viega

Viega Prevista Dry Plus 8545.31 User manual

Viega 8351.65 User manual

Viega

Viega 8351.65 User manual

Popular Plumbing Product manuals by other brands

Moen SANI-STREAM 8797 manual

Moen

Moen SANI-STREAM 8797 manual

Grohe Allure Brilliant 19 784 manual

Grohe

Grohe Allure Brilliant 19 784 manual

Cistermiser Easyflush EVO 1.5 manual

Cistermiser

Cistermiser Easyflush EVO 1.5 manual

Kohler Triton Rite-Temp K-T6910-2A installation guide

Kohler

Kohler Triton Rite-Temp K-T6910-2A installation guide

BEMIS FNOTAB100 Installation instruction

BEMIS

BEMIS FNOTAB100 Installation instruction

Hans Grohe ShowerTablet Select 700 13184000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe ShowerTablet Select 700 13184000 Instructions for use/assembly instructions

Akw Stone Wash Basin Installation instructions manual

Akw

Akw Stone Wash Basin Installation instructions manual

Enlighten Sauna Rustic-4 user manual

Enlighten Sauna

Enlighten Sauna Rustic-4 user manual

Moen ShowHouse S244 Series quick start guide

Moen

Moen ShowHouse S244 Series quick start guide

Sanela SLWN 08 Mounting instructions

Sanela

Sanela SLWN 08 Mounting instructions

Franke 7612982239618 operating instructions

Franke

Franke 7612982239618 operating instructions

Heritage Bathrooms Granley Deco PGDW02 Fitting Instructions & Contents List

Heritage Bathrooms

Heritage Bathrooms Granley Deco PGDW02 Fitting Instructions & Contents List

Tres TOUCH-TRES 1.61.445 instructions

Tres

Tres TOUCH-TRES 1.61.445 instructions

STIEBEL ELTRON WS-1 Operation and installation

STIEBEL ELTRON

STIEBEL ELTRON WS-1 Operation and installation

Miomare HG00383A manual

Miomare

Miomare HG00383A manual

BELLOSTA revivre 6521/CR1 quick start guide

BELLOSTA

BELLOSTA revivre 6521/CR1 quick start guide

American Standard Heritage Amarilis 7298.229 parts list

American Standard

American Standard Heritage Amarilis 7298.229 parts list

BorMann Elite BTW5024 quick start guide

BorMann

BorMann Elite BTW5024 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1 of 4
User Guide
Viega Flash Shower Valve
Model 2842.5
UG-PP 530594 0520 Flash Shower Valve 2842-5
Viega products are designed
to be installed by licensed and
trained plumbing and mechanical
professionals who are familiar with Viega
products and their installation.
Installation by non-professionals may
void Viega LLC’s warranty.
Recommended Tools
This document is subject to updates.
For the most current Viega technical
literature please visit www.viega.us.
To avoid shower rise or other related
issues, do not use PEX connections
at the tub outlet connecting to the
tub spout.
To ensure that your installation
proceeds smoothly, please read these
instructions carefully before you begin.
Compatible only with American
Standard pressure balance tub/shower,
shower only and valve only trims.
Visit www.americanstandard-us.com for more
information.
■ Phillips screwdriver
■ Flat blade screwdriver
■ Tubing cutter
■ Adjustable wrench
■ Channel locks
■ Plumber’s putty or caulking
Roughing-in Dimensions
To assure proper positioning in relation to wall,
note roughing-in dimensions.
犈犈
煍煍
Finished Wall ½ NPT
½ NPT
Top of tub rim
Bottom of tub
Optional to
finished floor
usually between
65 to 78
4
⅞ to 2
2¾ max.
1¾ min.
Inlets:
½ Stub Out
Outlets:
½ Stub Out
2 of 4
Viega Flash Shower Valve User Guide
UG-PP 530594 0520 Flash Shower Valve 2842-5
For back to back installation, follow
steps mentioned above. Reversal
of Hot/Cold water supplies is
accomplished by rotating cartridge (supplied
with trim) 180° during installation.
CAUTION!
After valve installation, inspect the
VALVE BODY for any debris. It can
damage Pressure Balance Valve cartridge.
CAUTION!
Turn off hot and cold water supplies
before beginning.
■ See Roughing-in diagram before starting.
■ Remove the PLASTER GUARD (8) for proper
installation.
■ Mount VALVE BODY to cross brace (2 x 4)
with-in wall. Use wood screws to secure
VALVE BODY to brace.
■ Connect HOT and
COLD water supplies.
See ProPress ½ to 2
Product Instructions
to make a ProPress
connection.
Standard Wall Installation ■ Connect RISER PIPE (1) to VALVE BODY (2)
top outlet marked “UP”.
■ Connect TUB FILLER PIPE (3) to bottom outlet.
■ Install PLASTER GUARD (8) back onto the
valve. Only remove PLASTER GUARD (8)
when ready to install trim Kit.
■ Finished wall should allow for a 4 diameter
opening (Use PLASTER GUARD for guidance)
To avoid shower rise or other related
issues, do not use PEX connections at the
tub outlet connecting to the tub spout.
Cross Brace
Cold
Hot
Wood
Screws
1
2
6
3
8
Side View
3½
4
2 x 4
Cross
Braces
⅞ to 2
2¾ max.
1¾ min.
ProPress ½ to 2
Product Instructions
3 of 4
Viega Flash Shower Valve User Guide
UG-PP 530594 0520 Flash Shower Valve 2842-5
For back to back installation, follow
steps mentioned above. Reversal
of Hot/Cold water supplies is
accomplished by rotating cartridge (supplied
with trim) 180° during installation.
CAUTION!
After valve installation, inspect the
VALVE BODY for any debris. It can
damage Pressure Balance Valve cartridge.
CAUTION!
Turn off hot and cold water supplies
before beginning.
Thin Wall Installation
■ See Roughing-in diagram before starting.
■ Finished wall should allow for a 3½ diameter
opening (Use PLASTER GUARD for guidance).
■ Remove PLASTER GUARD (8), rotate 90˚
counter clockwise and install the two screws.
(Thin wall text should be on top)
■ Use SELF-CENTERING HOLE GUIDES (9) as
a guide for thin wall install.
■ LOCKING SCREW (10) keeps valve in place
when installing. Completely Thread LOCKING
SCREW (10) onto PLASTER GUARD (8).
■ During the installation, make sure to position
the Locking feature screw as shown in Figure
A below. Once the valve is positioned on the
Thin Wall, turn counterclockwise as shown in
Figure B to secure VALVE BODY (2) in place.
■ Connect HOT and
COLD water supplies.
See ProPress ½ to 2
Product Instructions
to make a ProPress
connection.
■ Connect RISER PIPE (1)
to VALVE BODY (2) top
outlet marked “UP”.
■ Connect TUB FILLER
PIPE (3) to bottom outlet.
Side View
3½
1
2
8
9
10
10
10
3
Hot
Fig. A
Fig. B
Unlock
Lock
Cold
Hex
Wrench
4 mm
6
ProPress ½ to 2
Product Instructions
Viega LLC
585 Interlocken Blvd.
Broomfield, CO 80021
Phone (800) 976-9819
www.viega.us
Viega Flash Shower Valve User Guide
UG-PP 530594 0520 Flash Shower Valve 2842-5
Test Procedures For Flush Plug
■ Valve comes with Flush Plug that allows
hot and cold supply lines to be 󶈶ushed
independently (without cross 󶈶ow).
■ Flush plug is shipped in Orientation A.
■ ORIENTATION A directs cold water
through the shower port and hot water
through the tub port.
■ Flush plug can be reversed to Orientation B.
■ ORIENTATION B directs cold water
through the tub port and hot water
through the shower port.
■ For shower only installation 󶈶ush cold supply
line 󶈵rst in Orientation A. Then reverse to
Orientation B and 󶈶ush hot supply line.
Alternatively, the 󶈶ush plug can be removed
entirely to 󶈶ush water through the valve body.
■ To switch between orientations follow these
steps:
■ Unthread BONNET NUT (1).
■ Rotate FLUSH PLUG (2) 90 degrees to
desired orientation.
■ Rethread BONNET NUT (1).
■ Upon completion of 󶈶ushing both hot and
cold supply lines unthread BONNET NUT
(1), remove FLUSH PLUG (2), and rethread
BONNET NUT (1).


Shower
Tub
Hot Cold
2
Shower
Tub
Hot Cold
2
Orientation A (as shipped)
Orientation B