7
SW24.D
EN
LRNA
51 SLO
Leaf 1 opening slow down.
When button pressed: leaf 1 opening stop
position setting, if 51 is not pressed, the leaf
learns as the opening stopping position the
one obtained from the opening mechanical
stop
51 OPN2
Leaf 2 opening start.
When button pressed: leaf 2 opening slow
down position setting, the leaf proceeds at
slow down speed
51 SLO
Leaf 2 opening slow down.
When button pressed: leaf 2 opening stop
position setting, if 51 is not pressed, the leaf
learns as the opening stopping position the
one obtained from the opening mechanical
stop
51 CLS2
Leaf 2 closing start.
When button pressed: leaf 2 closing slow down
position setting, the leaf proceeds at slow
down speed
-SLO Leaf 2 continues closing at slow down speed
up to closing mechanical stop
51 CLS1
Leaf 1 closing start.
When button pressed: leaf 1 closing slow down
position setting, the leaf proceeds at slow
down speed
-SLO Leaf 1 continues closing at slow down speed
up to closing mechanical stop
51
0000
(second
count)
Leaf 1 opening start.
When button pressed: leaf 2 starts opening,
the control board learns and programs the
displayed opening delay between leaves. Leaf
1 and leaf 2 proceed to full opening
51
0000
(second
count)
Leaf 2 closing start.
When button pressed: leaf 1 starts closing,
the control board learns and programs the
displayed closing delay between leaves. Leaf 1
and leaf 2 proceed to full closing
-END End of procedure
Self-calibration:
If the gate travel parameter is changed, there is no need for the
installer to run new calibrations, however, when changing the travel
parameters, the control panel needs to learn the current curve again,
thus disabling the obstacle detection only during the self-calibration
cycle. Self-calibration is appropriately highlghted on the display that
shows 51, meaning that a command is required in order for the board
to self-calibrate.
The events generating self-calibration are:
- change in parameters: P09-10-11-12-13-14-15-16-17-18-19-20-21-
22-25-26-31-36-43.
PAR
Board parameters
Sub
menu Description Values
(default)
P01
Auto close (ON)
Auto close not active OFF
Auto close active ON
P02
Pause time (30)
2 s (minimum time) 2
600 s (maximum time) 600
P03
Command input n. 51 (1)
Collective
During the opening the command is not ac-
tive.
If P01 = ON when paused it restarts the
pause time and if the input 51 remains en-
gaged the control board suspends the count
until the input is disengaged (for the connec-
tion of coils or timers)
if P01 = OFF, when paused it closes back
During the closing it opens again
1
PAR
P03
Step-bystep (4 steps logic)
Cycle command Opens, Stops, Closes,
Stops, Opens…
2
Step-bystep (2 steps logic)
Cycle command Opens, Closes, Opens… 3
P04
Pre-ash
The ashing light ashes for 3 s before the
gate starts to move
(OFF)
Pre-ash not active OFF
3 s pre-ash active ON
P05
Immediate closing (OFF)
Immediate closing not active OFF
If the closing photocell is engaged and re-
leased during the opening or the pause time,
the control unit closes the gate, regardless
of the pause time set, 3 s after the complete
opening or 3 s after the release of the photo-
cell (depending on whether the release takes
place during opening or pause).
ON
P06
Safety input n. 63 (1)
Photocell (PH):
- with the gate stopped, does not allow the
gate to open
- during opening stops the movement and
when released proceeds with opening
- with the gate open, does not allow it to
close and when released will reload the
pause time
- on closing stops the movement and when
released reopens the gate
1
NC safety edge (BAR):
- with the gate stopped, does not allow the
gate to open
- in opening disengages, closes after the
pause time if auto close is active
- with the gate open, does not allow closing
and when released will reload the pause time
- in closing disengages and opens
2
8.2 KΩ balanced safety edge (8K2):
Same behaviour as the NC safety edge 3
P07
Output 14 type of open gate warning loght
(SCA) (OFF)
Gate closed: not active
Gate not closed: active xed OFF
Gate closed: not active
Gate in opening: slow ash
Gate not closed: active xed
Closing gate: quick ash
ON
P08
Safety input test (OFF)
Test not active OFF
Test active on input 62 1
Test active on input 63 2
Test active on both inputs 62 and 63 3
P09
M1 slowdown distance during closing
Knowing that 0 means full closing and 100
full opening, it shows where M1 switches
from normal speed to slow down speed on
closing
(30)
No slow down 0
Maximum closing slow down travel 100
P10
M2 slowdown distance during closing
Knowing that 0 means full closing and 100
full opening, it shows where M2 switches
from normal speed to slow down speed on
closing
(30)
No slow down 0
Maximum closing slow down travel 100