Features
• The positive-off thermostat controls the
element allowing for adjustable and more
consistent temperatures. A signal light indicates
that the heating element is energized.
• Control is recessed in a one-piece, drawn,
stainless steel panel to help prevent accidental
temperature changes.
• Each unit has a large 1-inch drain with
removable screen for easy cleaning.
• Interior and top flange are heavy-duty
(18 gauge) stainless steel for maximum
strength and durability.
• Adapter bars are included with each unit
to allow the use of a variety of different
sized pans.
• The Bain Marie warmers are designed for
wet operation only.
•
Wellslok allows for quick and easy installation
in stainless steel countertops.
• The Bain Marie Warmers are Underwriters
Laboratories, Inc. LISTED and meet NSF
International and Canadian standards.
• A one-year warranty against defects
covers parts and labor.
The Wells 12” x 27” Drop-in Bain Marie Warmers economically meet your volume needs,
designed with 33% more capacity than the standard Bain Marie warmers. The versatile heated
tank can accommodate a variety of round or rectangular insets. The heavily insulated single
warming pan and large volume provide consistent temperatures.
HT-327
Accessories / Options
Wellslok Extension Kit, designed for
installation in a variety of countertops
up to 1-1/2” thick, refer to installation
instructions, 22593
Drain Screen, 21709
Optional 72” Wiring, thermostatically
controlled warmers, priced per well
(standard length is 24”) contact factory.
WE L L S M A N U F A C T U R I N G
WELLS MANUFACTURING COMPANY
2 ERIK CIRCLE, PO BOX 280, VERDI, NV 89439 U.S.A.
USA PHONE: (775) 345-0444 • FAX: (775) 345-0569
FOR ORDERS ONLY: (888) 356-5362 • FAX: (800) 356-5142
www.wellsbloomfield.com
© 2002 WELLS MANUFACTURING • PRINTED IN THE U.S.A.
03/02 • REV(A) • PART NO. 300711
MODEL
H T- 5 2 7
D R O P - I N B A I N M A R I E WA R M E R
DIMENSIONS: INCH
(MM) MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE
BACK SIDE BOTTOM FRONT
1 1 10 3/4 4 1/8
(25) (25) (273) (105)
LISTED
E6070
STD.4 LISTED
RR
R
C
E6070
NOTE: Specifications are subject to change without notice. See installation instructions prior to installing the unit.
This document is not for installation purposes.
H T- 5 2 7 E L E C T R I C A L S P E C I F I C AT I O N S :
MODELS VOLTS WATTS AMPS PER LINE 3 PHASE AMPS POWER
SINGLE PHASE SUPPLY CORD
L1 L2 L3
HT-527 208 6200 17.9 25.8 11.9 29.8 NONE
HT-527 240 8300 20.6 29.8 13.8 34.4 NONE
(98)
3 7/8
(159)
6 1/4
(778)
30 5/8
(683)
26 7/8
A
B
(356)
14
(248)
9 3/4
FLEXIBLE CONDUIT
CONTROL PANEL WITH W/ BALL VALVE
1" NPT DRAIN
DIMENSION SPECIFICATIONS:
HT-527 67 3/4 (1721) 71 1/2 (1816)
MODELS
DIMENSION 'A' DIMENSION 'B'
INCHES MM INCHES MM
Specifications
Temperature Settings: OFF/LO to HI
Weights: Lbs. KG
HT-227:
Installed 49 22
Shipping 59 27
HT-327:
Installed 71 32
Shipping 85 39
HT-427:
Installed 94 43
Shipping 101 46
HT-527:
Installed 101 46
Shipping 122 55