manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Wolf
  6. •
  7. Cooktop
  8. •
  9. Wolf RT484CG Instructions for use

Wolf RT484CG Instructions for use

Other manuals for RT484CG

2

This manual suits for next models

5

Other Wolf Cooktop manuals

Wolf CT30EU Instructions for use

Wolf

Wolf CT30EU Instructions for use

Wolf SRT484CG User manual

Wolf

Wolf SRT484CG User manual

Wolf Gas cooktop User manual

Wolf

Wolf Gas cooktop User manual

Wolf CT30E/S User manual

Wolf

Wolf CT30E/S User manual

Wolf Cooktop User manual

Wolf

Wolf Cooktop User manual

Wolf CT36E/B User manual

Wolf

Wolf CT36E/B User manual

Wolf CT30G Instructions for use

Wolf

Wolf CT30G Instructions for use

Wolf CT36IU User manual

Wolf

Wolf CT36IU User manual

Wolf CI365C/B User manual

Wolf

Wolf CI365C/B User manual

Wolf ICBCI152 User manual

Wolf

Wolf ICBCI152 User manual

Wolf ICBCT30I User manual

Wolf

Wolf ICBCT30I User manual

Wolf CI304T/S User manual

Wolf

Wolf CI304T/S User manual

Wolf IM15/S User manual

Wolf

Wolf IM15/S User manual

Wolf SRT304 User manual

Wolf

Wolf SRT304 User manual

Wolf Induction Cooktop Operating manual

Wolf

Wolf Induction Cooktop Operating manual

Wolf CT15I User manual

Wolf

Wolf CT15I User manual

Wolf SRT364C Instructions for use

Wolf

Wolf SRT364C Instructions for use

Wolf ICBCT15I/S Owner's manual

Wolf

Wolf ICBCT15I/S Owner's manual

Wolf 381 User manual

Wolf

Wolf 381 User manual

Wolf CT30E Instructions for use

Wolf

Wolf CT30E Instructions for use

Wolf CE152T/S/208 User manual

Wolf

Wolf CE152T/S/208 User manual

Wolf CT36G/P Owner's manual

Wolf

Wolf CT36G/P Owner's manual

Wolf ICBCT15G/S User manual

Wolf

Wolf ICBCT15G/S User manual

Wolf CG365C/S Guide

Wolf

Wolf CG365C/S Guide

Popular Cooktop manuals by other brands

Bonnet OPTIMUM 700 Technical instructions

Bonnet

Bonnet OPTIMUM 700 Technical instructions

Jenn-Air JGCP430 installation instructions

Jenn-Air

Jenn-Air JGCP430 installation instructions

Frigidaire FES367FCC Wiring diagram

Frigidaire

Frigidaire FES367FCC Wiring diagram

Ztove EZ2 DUO instruction manual

Ztove

Ztove EZ2 DUO instruction manual

Kleenmaid cooking GCTK9011 Instructions for use and warranty details

Kleenmaid

Kleenmaid cooking GCTK9011 Instructions for use and warranty details

Jenn-Air JGC2536EB00 Use & care guide

Jenn-Air

Jenn-Air JGC2536EB00 Use & care guide

Waldorf RN8603E-B Technical data sheet

Waldorf

Waldorf RN8603E-B Technical data sheet

Whirlpool SMP658CNEIXL quick guide

Whirlpool

Whirlpool SMP658CNEIXL quick guide

Fulgor Milano F5PGK305S1 installation instructions

Fulgor Milano

Fulgor Milano F5PGK305S1 installation instructions

GE JP389 Specifications

GE

GE JP389 Specifications

Wells WV-2HFG owner's manual

Wells

Wells WV-2HFG owner's manual

IKEA Lagan HGA4K user manual

IKEA

IKEA Lagan HGA4K user manual

Samsung NA36N9755 installation manual

Samsung

Samsung NA36N9755 installation manual

Miele KM 404 operating instructions

Miele

Miele KM 404 operating instructions

Lacor 69562 Instructions for use and maintenance

Lacor

Lacor 69562 Instructions for use and maintenance

Keating Of Chicago MG-2 manual

Keating Of Chicago

Keating Of Chicago MG-2 manual

Jenn-Air CCE1400 Use and care guide

Jenn-Air

Jenn-Air CCE1400 Use and care guide

KitchenAid KGCP482KSS0 parts list

KitchenAid

KitchenAid KGCP482KSS0 parts list

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Planning Information
48" (1219) Gas Rangetops
MODELS RT488, RT486C, RT486G, RT484CG, RT484DG AND RT484F
1
Dimensions in parentheses are in
millimeters unless otherwise specified.
9/07
The Wolf 48" (1219) gas rangetop is
available in natural or LP gas, with your
choice of several top configurations.
Model numbers indicate the features;
(C) charbroiler, (G) griddle, (DG) double
griddle and (F) French top. The model
number followed by (-LP) denotes an LP
gas model.
If you want to offer a more professional look to your
client’s kitchen and still use a cooktop, look to the gas
rangetops from Wolf. They offer you that commercial
look but give you flexibility to use the ovens in other
locations in the kitchen. In fact, the Wolf framed ovens
would be a beautiful complement to these cooking
instruments.
Wolf gas rangetops offer a variety of top configurations
and standard dual brass surface burners. Optional
infrared griddle, infrared charbroiler and French Top give
you the freedom to customize your gas rangetop.
Let Wolf, the corporate companion and kitchen soul
mate of Sub-Zero, fuel your passion for cooking and
kitchen design.
Model RT484CG shown.
This appliance is certified by Star-K
to meet strict religious regulations in
conjunction with specific instructions
found on www.star-k.org.
Model RT488
Model RT486C
Model RT486G
Model RT484CG
Model RT484DG
Model RT484F
Porcelain-coated
cast iron top grates
Dual brass
burners
Stainless steel
exterior finish
Infrared charbroiler
(optional)
Infrared griddle
(optional)
Low-profile
island trim
Griddle indicator
light
Pull-out drip
tray
Large red
control knobs
Location of
rating plate
Planning Information
48" (1219) Gas Rangetops
MODELS RT488, RT486C, RT486G, RT484CG, RT484DG AND RT484F
2
48" (1219)
OVERALL WIDTH
20" (508)
WITH
101/2"
RISER
24" (610)
271/4" (692)
OVERALL DEPTH
TO KNOBS
23/4" (70)
101/2" (267)
OVERALL
HEIGHT
91/2"
(241)
2"
(51)
COOKING
SURFACE
OVERALL DIMENSIONS
FEATURES
Natural or LP gas models
Fits standard 24" (610) deep cabinets with
zero clearance for easy installation
Optional infrared charbroiler, infrared griddle
and French Top configurations
Classic stainless steel exterior finish
Dual brass burners with automatic reignition
at all settings, 500 Btu/hr (.1 kW) simmer to
16,000 Btu/hr (4.7 kW) high
Porcelain-coated cast iron top grates
Large red control knobs with four position
settings and chrome bezels—optional black
knobs available
Stainless steel drip tray on ball bearing slides
High altitude conversion kit available
CSA certified for US and Canada
Two and five year residential warranty—
exclusions apply; warranty information can
be found on our website, wolfappliance.com
Dimensions in parentheses are in
millimeters unless otherwise specified.
Unit dimensions may vary by ±
1
/
8
" (3).
Planning Information
48" (1219) Gas Rangetops
MODELS RT488, RT486C, RT486G, RT484CG, RT484DG AND RT484F
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
MODEL OPTIONS
Eight Burners RT488
Six Burners / Charbroiler RT486C
Six Burners / Griddle RT486G
Four Burners / Charbroiler
and Griddle RT484CG
Four Burners / Double
Griddle RT484DG
Four Burners / French Top RT484F
Natural gas models listed, for LP gas add
(-LP) to the model number.
VENTILATION OPTIONS
48" (1219) Pro wall or wall
chimney hood or liner
54" (1372) Pro wall, wall chimney
or island hood or liner
Also refer to the Pro Ventilation section of
our website, wolfappliance.com.
ACCESSORIES
10 1/2" (267) classic stainless steel
riser
Classic stainless steel island trim
Black control knobs
Porcelain-coated, cast iron wok
grate
Porcelain-coated, cast iron two-
burner S-grates
Hardwood cutting board—griddle
models only
High altitude conversion kit
Accessories are available through your
Wolf dealer. To obtain local dealer
information, visit the Showroom Locator
section of our website, wolfappliance.com.
SPECIFICATIONS
Overall Rangetop Width 48" (1219)
Overall Rangetop Height
(to cooking surface) 101/2" (267)
Overall Rangetop Depth 27 1/4" (692)
Surface Burners
16,000 Btu/hr (4.7 kW) burners with 500 Btu/hr
(.1 kW) delivered at simmer
Infrared Charbroiler 16,000 Btu/hr (4.7 kW)
Infrared Griddle 18,000 Btu/hr (5.3 kW)
Double Griddle (two burners) 18,000 Btu/hr (5.3 kW)
French Top 15,000 Btu/hr (4.4 kW)
Opening Width 48 1/4" (1226)
Opening Height
(platform to countertop) 9 1/2" (241)
Opening Depth 24" (610)
Electrical Supply Requirements 110/120 V AC, 50/60 Hz
15 amp circuit
Power Cord 6' (1.8 m) power cord
with grounded plug
Shipping Weight 220 lbs (100 kg) – 280 lbs (127 kg)
Specifications are subject to change without notice.
IMPORTANT NOTE: In non-island applications, a riser is required
when installing a gas rangetop against a combustible surface.
Planning Information
48" (1219) Gas Rangetops
MODELS RT488, RT486C, RT486G, RT484CG, RT484DG AND RT484F
Dimensions in parentheses are in
millimeters unless otherwise specified.
4
VENTILATION HOOD
14"
(356)
16"
(406)
LOCATION OF GAS AND
ELECTRICAL SUPPLY CUT-OUT
WITHIN SHADED AREA
THROUGH BOTTOM OF
PLATFORM
TOP VIEW
OF PLATFORM
E G
16"
(406)
3"
(76) BACK WALL
1/2"
(13)
481/4" (1226)
FINISHED ROUGH OPENING WIDTH
3/4" (19) PLATFORM
6"min (152)
TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
30"min (762)
TO 36"max (914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
30"min (762)
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
36"min (914)
FOR CHARBROILER
23/4"
(70)
ISLAND INSTALLATIONS: 12" (305) MINIMUM
CLEARANCE FROM BACK OF RANGETOP TO
COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–
0" (0) TO NON-COMBUSTIBLE MATERIALS
3/4" (19) PLATFORM
91/2" (241)
OPENING
HEIGHT
24" (610)
13" max
(330)
36"
(914)
18"min (457)
TO COUNTERTOP
INSTALLATION SPECIFICATIONS
DIMENSIONS
Overall Width of Rangetop 48" (1219)
Finished Rough Opening Width 48 1/4" (1226)
Finished Rough Opening Height (platform to countertop) 9 1/2" (241)
Finished Rough Opening Depth 24" (610)
Location of Electrical and Gas Supply Within shaded area
See Installation Instructions shipped with unit for detailed specifications.
Planning Information
48" (1219) Gas Rangetops
MODELS RT488, RT486C, RT486G, RT484CG, RT484DG AND RT484F
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
INSTALLATION NOTES
Refer to the illustrations and specifications
for overall dimensions, finished rough opening
dimensions and installation specifics.
IMPORTANT NOTE: Caution must be used in
planning the proper installation of the Wolf gas
rangetop to avoid any fires or damage to
adjacent cabinetry or kitchen equipment. Be
sure to follow minimum clearances established
in the finished rough opening dimensions as
shown in the illustration on page 4.
IMPORTANT NOTE: In non-island applications,
a riser is required when installing a gas rangetop
against a combustible surface.
The platform for the rangetop must be 3/4"
(19) thick and include a cut-out at the right rear
for gas supply and electrical connections. The
platform must be level to ensure that the
cooking surface is level.
A Wolf Pro ventilation hood or hood liner is
recommended. When installing a ventilation
hood, refer to the specific requirements of the
hood for the minimum dimension to countertop.
Also refer to the ventilation recommendation
charts in the Pro ventilation section of our
website, wolfappliance.com.
The Wolf gas rangetop requires a 110/120 V
AC, 50/60 Hz electrical supply to operate the
electronic ignition system. The 6' (1.8 m) power
supply cord provided with the rangetop is
equipped with a 3-prong, grounded plug for
protection against shock hazard. The service
should have its own 15 amp circuit breaker.
Locate electrical within the shaded area shown
in the illustration on page 4.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
Wolf gas rangetops are designed to operate
on natural gas at 5" (12.5 mb) WC (water
column) pressure or LP gas at 10" (25 mb) WC
pressure. The minimum line pressure for natural
gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC
for LP gas. The maximum gas supply pressure
to the regulator should never exceed 14" (34.9
mb) WC; .5 psi (3.5 kPa).
Wolf recommends the use of a 1/2" (13) I.D.
commercial type flex hose; this is the minimum
size that may be used. All plumbing to the flex
hose must be 3/4" (19) minimum I.D. pipe.
IMPORTANT NOTE: A separate external gas
shut-off valve must be located near the range in
an accessible location.
You must follow all National Electrical Code
and gas regulations. In addition, be aware of
local codes and ordinances when installing
your services.
Wolf gas rangetops using natural gas
function up to an altitude of 8,000' (2438 m)
without any adjustment. Natural gas and LP gas
installations from 8,000' (2438 m) to 11,000'
(3353 m) need the high altitude kit. Contact
your Wolf dealer for details. To obtain local
dealer information, visit the Showroom Locator
section of our website, wolfappliance.com.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.