WURM FGT004 User manual

Other WURM Control Unit manuals

WURM FKL003-A User manual

WURM

WURM FKL003-A User manual

WURM HVL-G3 User manual

WURM

WURM HVL-G3 User manual

WURM FKV003 User manual

WURM

WURM FKV003 User manual

WURM FKV003 User manual

WURM

WURM FKV003 User manual

WURM EEV module User manual

WURM

WURM EEV module User manual

WURM Frigolink FVB110B User manual

WURM

WURM Frigolink FVB110B User manual

WURM FRIGOLINK ANI-1F1-A User manual

WURM

WURM FRIGOLINK ANI-1F1-A User manual

WURM FKV003-A User manual

WURM

WURM FKV003-A User manual

WURM FKL003-A User manual

WURM

WURM FKL003-A User manual

WURM FRIGOLINK ANI-2F1-A User manual

WURM

WURM FRIGOLINK ANI-2F1-A User manual

WURM FVB240-PAT User manual

WURM

WURM FVB240-PAT User manual

WURM DSC-XP User manual

WURM

WURM DSC-XP User manual

WURM DOC-XP User manual

WURM

WURM DOC-XP User manual

WURM HCO2-G4 User manual

WURM

WURM HCO2-G4 User manual

WURM FRIGOLINK ANI-1F1 User manual

WURM

WURM FRIGOLINK ANI-1F1 User manual

WURM FVB140-PAT User manual

WURM

WURM FVB140-PAT User manual

WURM FVB110-PAT User manual

WURM

WURM FVB110-PAT User manual

WURM FRIGOLINK ANI-1F3 User manual

WURM

WURM FRIGOLINK ANI-1F3 User manual

WURM FKL003 User manual

WURM

WURM FKL003 User manual

WURM HMS-G3 User manual

WURM

WURM HMS-G3 User manual

WURM FRIGOLINK ANI-1F1 User manual

WURM

WURM FRIGOLINK ANI-1F1 User manual

WURM DCT-XP User manual

WURM

WURM DCT-XP User manual

WURM FRIGOLINK ANI-2F1-A User manual

WURM

WURM FRIGOLINK ANI-2F1-A User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Field module for building technology solutions
FGT004_V4.2.0_PI_2023-02_EN 1
Subject to technical changes
FGT004
1 FGT004
Field module for building technology solutions
1.1 Front view
Fig. 1: Front view
1.2 Features
• Inputs and outputs
- Constant output 0...10V
- PWM output 0…10V
- 1 x Analogue input 0...10V / 4...20mA
- 1 x Analogue input 4...20mA
- 3 x digital input 24V=
- 4 x temperature sensor (TRK277, DGF980)
- 3 x relay (2 x NC contact, 1 x NO contact)
• Connection of an external display
• Emergency program in case of bus errors
• No parameters to be set on the device
• Bus connection by patch cable and screw terminals (4-pin)
• Connection to master module via Wurm CAN field bus (F-bus)
Field module for building technology solutions
2 FGT004_V4.2.0_PI_2023-02_EN
Subject to technical changes
FGT004
1.3 Safety instructions
Writing conventions
WARNING • Avoid the described hazard: otherwise, electric voltage represents a danger that could lead to
fatal or serious bodily injury.
CAUTION • Avoid the described hazard: otherwise, minor or intermediate physical injury or damage to
property will result.
For your safety
For safe operation and to avoid personal injury and equipment damage through operator error, always
read these instructions, become familiar with the device, and follow all safety instructions on the prod-
uct and in this document, as well as the safety guidelines of Wurm GmbH & Co. KG Elektronische
Systeme. Keep these instructions ready to hand for quick reference and pass them on with the device
if the product is sold.
Wurm GmbH & Co. KG Elektronische Systeme accepts no liability in the case of improper use or use
for purposes other than the intended purpose.
WARNING DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
• Switch off the power to the entire plant when carrying out installation, wiring or disassembly work!
Otherwise, mains voltage and/or external voltage may still be present, even if the control voltage
is switched off! Always remove both power plugs (L and N).
• The wiring of the device must be carried out only by qualified electricians!
• Use the correct tools for any work!
• Check the entire wiring after connection!
• Observe the maximum loads for all connections!
• Never expose the device to moisture, for example due to condensation or cleaning agents.
• Stop operating the device if it is faulty or damaged and its safe operation is compromised!
• Do not open the device.
• Do not repair the device yourself! If the device requires repairs, send it in with an exact descrip-
tion of the fault!
CAUTION ELECTROMAGNETIC INTERFERENCE MAY CAUSE FAULTS!
• Always use shielded data cables and place them far away from power lines.
Version and validity of the documentation
Any versions not listed are special solutions for individual projects and are not described in detail in this document.
This document will automatically cease to be valid if a new technical description is issued.
Manufacturer: Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid
You can find more information on our website at www.wurm.de.
Target group This manual is intended for "service technician" personnel.
Intended use The FGT004 is a field module for building technology solutions.
Version Date
V4.2.0
and higher
2023-02 Documentation status
Field module for building technology solutions
FGT004_V4.2.0_PI_2023-02_EN 3
Subject to technical changes
FGT004
1.4 Connection diagram
Fig. 2: Connection diagram
1.5 Installing the device
This device is designed for top-hat rail installation. The housing has standard DIN 43880 dimensions
and is suitable for installation in fuse boxes, distribution cabinets, or the load sections of refrigeration
units.
The device can be positioned immediately adjacent to another device without gaps.
WARNING
DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
• Switch off the power to the entire plant before installing. Otherwise, mains voltage and/or exter-
nal voltage may still be present, even if the control voltage is switched off. Always remove both
power plugs (L and N).
The entire plant must be free of voltage.
1. (A) Place the device with the leading edge at an acute angle to the top-hat rail.
2. (B) Push the device downwards onto the top-hat rail.
The device snaps into place with the fastening safety catch (a) on the top-hat rail.
You can now connect the device.
Fig. 3: Top-hat rail installation
 

   
            
   
      

7
..$9a
0RGXOH
QR
)*7
A
B
Field module for building technology solutions
4 FGT004_V4.2.0_PI_2023-02_EN
Subject to technical changes
FGT004
1.6 CAN bus address setting
To correctly register the FGT004 on the CAN bus, you must assign it a unique CAN bus address using
a coding switch. This is a requirement for functioning communication with the master module.
You can set CAN bus addresses 0-F with the coding switch. You can thus connect 16 field modules
to the CAN bus.
Fig. 4: Coding switch
1.7 Technical data
Power supply 230V~, +10% / -15%, max. 10VA
Display 1 x green LED, operating voltage
2 x green LED, CAN bus data traffic (CAN Tx, CAN Rx)
1 x red LED, flashes in case of fault
Communication 3-wire CAN bus interface, shielded, galvanically isolated,
screw terminals or RJ45 socket (2 x)
Temperature sensor 4 x TRK277 / DGF980
Analogue input 1 x 4…20mA or 0…10V=, 22V= supply voltage
1 x 4...20mA, 22V= supply voltage
Digital inputs 24V=, +20% / -10%, approx. 5mA per input
Output relay 2 x NC contact, 230V~, 4(2)A
1 x normally open contact, 230V~, 4(2)A
Display/circuit breaker
connection
1 x socket for assembled line to display DSP002, DSP100,
DSP-LCD, DSP-Booster or for controlling an ECA970 circuit
breaker
Analogue output 1 x 0...10V=, non-floating, max. load 10mA
PWM output 1 x 0...10V=, non-floating, max. load 10mA
Dimensions (W x H x D) 106 x 90 x 58mm (DIN 43880)
Fastening Top-hat rail TH 35-15 or TH 35-7.5 (DIN EN 60715)
Ambient temperature Operation: 0...+55°C, storage: -25...+70°C
Weight About 275g
Conformities - 2014/30/EU (EMC Directive)
- 2014/35/EU (Low Voltage Directive)
RoHS II
7