● UTILITIES > CALIBRATE
Before first printing, please calibrate the bed to guarantee an appropriate levelness of the bed for printing.
● Calibration Instruction
Print Bed Adjustment
UTILITIES
CALIBRATE
TIPS FOR TURNING
1 STEP=90 DEGREE
4 STEPS=1 CIRCLE
[ OK] TO CONTINUE
TURN FRONT KNOB
TO THE RIGHT :
8.7 STEPS
[OK] TO NEXT
After the printer is heated up to an appropriate
temperature, the distances between measurement
points on bed edge 1、2、3、4and probes
are measured automatically to determine levelness
of the bed.
There are three white 4-step knobs under the bed. Each step of turning indicates 90 degrees
of rotation, and 4 steps of flick indicate a complete circle of rotation of the knob as shown in
the messages on screen. Press“OK" key to continue viewing adjustment instructions.
After flicking the knobs in accordance with instruction, the printer will detect the levelness of the bed again. As "PERFECT" is displayed form
the detection result, print may be started.
If the measurement point of the bed is stained or the bed is too high or too low, wrong measurement will occur and the warning of
“CALIBRATE FAIL” will be shown on the screen. Please adjust the print bed.
Knobs corresponding to this procedure
Turning direction
Number of turning steps (each step indicates 1 tick/90 degrees of rotation)
After flicking knob in accordance with prompt, press "OK" key to continue
(There are three white 4-step knobs under
the bed. Each step of turning indicates
90 degrees of rotation and 4 steps of flick
indicate a complete circle of rotation of the
knob.)
Knob Location and Adjustment Direction
1 STEP
4 STEP
3 STEP
2 STEP
FRONT KNOB
Description for Instruction on Screen
TURN FRONT KNOB
TO THE RIGHT - Turn the front knob rightwards
TO THE LEFT - Turn the front knob leftwards
Instruction for Direction
Adjustment:
32
41
RIGHT KNOB
Description for Instruction on Screen
TURN RIGHT KNOB
BACKWARDS - Turn the right knob backwards
FORWARDS - Turn the right knob forwards
LEFT KNOB
Description for Instruction on Screen
TURN LEFT KNOB
BACKWARDS - Turn the left knob backwards
FORWARDS - Turn the left knob forwards
FRONT KNOB
RIGHT KNOB
BACKWARDSBACKWARDS
FORWARDSFORWARDS
TO THE RIGHTTO THE LEFT
LEFT KNOB
●
Functional operations and descriptions
PERFECT
ADJUST MORE ?
> YES
NO
If the automatic detection function determines that there is no need to adjust levelness of the
bed, "PERFECT" will be displayed on screen. At this moment, press "NO" to exit.
If it displays that the bed has to be adjusted from the detection result, an adjustment prompt will
be displayed.
●