4
43
☞
E
☞
Q
VENT.
M
L
After having ignited the heater, always check whether the combustion
chamber Dis level, by sliding it slightly to the left and the right by its handle E
(Fig. E). This should be a smooth movement. If the combustion chamber is not
level, this will cause smoke and soot to develop.
DBURNING OF THE HEATER
After you have ignited the heater, it will take 10 to 15 minutes before you can check
whether the heater is burning well. Too high a flame may cause smoke and soot,
whereas too low a flame causes smells. The page opposite the folding page shows
the minimum and maximum permissible burning heights of the flame (Fig. P).
If the flame remains low after the adjustment, the wick height must be
adjusted (refer to Section F).
Burning that is too low may be caused by:
Einsufficient fuel (fill the tank)
Epoor fuel quality (contact your dealer)
Einsufficient ventilation (put window or door ajar)
Ewastage of the wick (contact your dealer or replace the wick,
refer to section L)
When there is insufficient ventilation in the room, an intermittent buzzer will be
heardand the VENT lamp (Yellow) will be lit (Fig. Q) . When this signal is given,
ensure that the ventilation of the room is improved (e.g. by opening a door or
window a little more) to avoid that the heater shuts off. When the ventilation of
the room is improved, the VENT lamp and buzzer will be deactivated. When there
is still insufficient ventilation, the heater shuts offautomatically. After improving
the ventilation of the room (e.g. by opening a door or window a little more), the
heater can be ignited again.
This heater is fitted with a safety system that ensures that it switches off if you
lift the exchange tank out of the heater. To switch the heater on again, put the
exchange tank back and follow the steps in chapter C.
ESWITCHING OFF THE HEATER
Push the OFF-button A.The flame will extinguish after a little while (Fig. L).
FMALFUNCTION, CAUSES AND SOLUTIONS
If any malfunctioning cannot be solved from the directions below,please contact
your dealer.
THE HEATER DOES NOT IGNITE
EThe batteries arenot positioned correctly in the holder.Check (Fig. M).
EThereis not enough power left in the batteries for the ignition.Replace(Fig. M).
EYou have run out of fuel from the tank or the wick has been replaced.
After having refilled and replaced the removable tank, wait for 30 minutes
beforeigniting the heater.
EYou are pushing the ignition button Cwith too much force.
Push it in less forcefully (Section C).
EThe ignition coil Kis defective. Contact your dealer.