ZKTeco ProBio User manual

ProBio(QR)
Version: 1.0
Date: May 2021
QUICK START GUIDE

Safety Precautions
Before installation, please read the following precautions carefully
risks and dangers to this product, users and surroundings.
to prevent
Do not expose to direct sunlight, water, dust and soot.
Do not place magnetic object near the product. Magnetic objects
such as Magnet, , , Monitor or Speaker may damage the device.
any
CRT TV
Do not place the device next to any heating equipment.
Prevent water, drinks or chemicals leaking into the device.
This product is not intended for use by children unless they are supervised.
Do not drop or damage the device.
Do not disassemble, repair or modify the device.
Do not use the device for any purpose other than those specified.
Remove dusts or dirts regularly. While cleaning, wipe dust off with a
smooth cloth or towel instead of water.
Contact your supplier in case of any problem!
1

2
User Registration
1.15m
0.5m
1.15m
0.5m
1.15m
0.5m
For user heights between 1.5m to 1.8m, it is recommended
to install the device at 1.15m height above ground (can be
modified according to the user’s average height).
2) Registration
a. During registration, it is required to adjust your upper body to fit your eyes into the green
frame on the screen.
b. During verification, it is required to show your face in the center of the screen and fit your face
into the green frame in the screen.
1) Recommended Standing Position
Recommended Procedures (as shown in
the left image): During registration and
verification procedures, the position of device
should not be changed to
verification preciseness. If it is necessary to
move the device, its vertical height should
not be changed.
ensure high

Device Overview
2.8" Touch Screen
Doorbell
Camera
Card Reading Area
& QR Code Scanner
USB Port
Reset Button
Tamper Switch
Terminal Block
Speaker
3
85mm (3.35")
190.8mm (7.51")
103mm (4.05")

4
Device Installation
Installation on the wall
1.15m
10
11
12
13
FixingHole
14
15
FixingHole
Mounting PositioningSticker
(only for your reference)
Instructionon using Mounting Positioning Sticker:
WiringHole
FixingHole FixingHole
1.15mrecommended height from the ground
forfacial terminal and 1.4m for finger vein
terminal,it can be adjusted according to
thestaff height.
Beforefastening the device, please stick this
MountingPositioning Sticker onto where you want to
installthe device, and then drill holes and lay cables
accordingto the symbols on the sticker.
MPS201508
①
②
③
④
Attach the mounting template sticker to the wall, and drill holes according to the mounting
paper.
Fix the back plate on the wall using the wall mounting screws.
Attach the device to the back plate.
Fasten the device to the back plate with a security screw.
Baseline 129 mm (5.08")
61mm (2.4")

5
Power Connection
Without UPS
With (Optional)UPS
GND
12V DC
GND
12V DC
PowerIn
Lock
Alarm
Button
Sensor
Bell
In
Out
Ethernet
Power
Out
In
RedLED
Beep
Green
GND
WD1
WD0
GND
+12V
GND
Wiegand
485B
485A
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
RS485
Wiegand
+12V
BELL-
BELL+
SEN
AUX
GND
GND
BUT
N1O
COM1
N1C
AL-
AL+
{
{
{
{
{
{
{
{
{
{
{
{
{
RLED
BEEP
GLED
TXD
RXD
GND
RS232
Auxiliary
LED
PowerIn
Lock
Alarm
Button
Sensor
Bell
In
Out
Ethernet
Power
Out
In
RedLED
Beep
Green
GND
WD1
WD0
GND
+12V
GND
Wiegand
485B
485A
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
RS485
Wiegand
+12V
BELL-
BELL+
SEN
AUX
GND
GND
BUT
N1O
COM1
N1C
AL-
AL+
{
{
{
{
{
{
{
{
{
{
{
{
{
RLED
BEEP
GLED
TXD
RXD
GND
RS232
Auxiliary
LED
12V DC
12V DC
1
2
1
2
Recommended AC Adapter
Recommended AC Adapter 12V A3:,
To share the power with other devices, use an with higher current ratings.AC Adapter

6
Ethernet Connection
RJ 45
8
7
6
5
4
3
2
1
LAN Connection
RJ45-1 Yellow
RJ45-2
Red
RJ45-3
RJ45-6 Black
Green
WIRE
DESCRIPTION
ZKBioSecurity
PowerIn
Lock
Alarm
Button
Sensor
Bell
In
Out
Ethernet
Power
Out
In
RedLED
Beep
Green
GND
WD1
WD0
GND
+12V
GND
Wiegand
485B
485A
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
RS485
Wiegand
+12V
BELL-
BELL+
SEN
AUX
GND
GND
BUT
N1O
COM1
N1C
AL-
AL+
{
{
{
{
{
{
{
{
{
{
{
{
{
RLED
BEEP
GLED
TXD
RXD
GND
RS232
Auxiliary
LED
Connect the device and the software over an Ethernet cable. An example is shown below:
: 192.168.1.201Default IP Address
Subnet Mask: 255.255.255.0
: 192.168.1.61
: 255.255.255.0
IP Address
Subnet Mask
1
4
Click , enter the IP address and click .[Comm.] > [Ethernet] > [IP Address] [OK]
Note:
In LAN, the IP Addresses of the Server (PC) and the device must be in the same network
segment when connecting to the ZKBioSecurity software.

7
RS485 Connection
Rs485 Slave Reader
Do not use
BEEP Purple
GLED Gray
IWD1 Green
RLED Blue
+2V1Red
GND Black
IWD0 White
DESCRIPTION WIRE
485B Yellow
485A Blue
GND Black
TXD Purple
GND Black
WD0 Green
WD1 White
RXD Gray
DESCRIPTION WIRE
PowerIn
Lock
Alarm
Button
Sensor
Bell
In
Out
Ethernet
Power
Out
In
RedLED
Beep
Green
GND
WD1
WD0
GND
+12V
GND
Wiegand
485B
485A
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
RS485
Wiegand
+12V
BELL-
BELL+
SEN
AUX
GND
GND
BUT
N1O
COM1
N1C
AL-
AL+
{
{
{
{
{
{
{
{
{
{
{
{
{
RLED
BEEP
GLED
TXD
RXD
GND
Rs232
Auxiliary
LED
Rs485 Slave Reader Connection
1
8
17
DIP Settings
123456
ON
123456
ON
1. There are six DIP switches on the back of RS485 slave reader, switches 1 to 4 are for RS485
address, switch 5 is reserved, and switch 6 is for reducing noise on a long RS485 cable.
2. If the RS485 slave reader is powered from the terminal, the length of wire should be less
than 100 meters or 330 ft.
3. If the cable length is more than 200 meters or 600 ft., the number 6 switch should be
turned ON as shown below.
Distance: More than 200 metersDistance: 200 metersLess

Lock Relay Connection
8
!
Device Not Sharing Power with the Lock
Normally Closed Lock
GND
Sensor
12V DC
COM1
12V DC
1
12
GND GND
AUX
GND
BELL-
Yellow
BELL+
SEN
GND Red
BUT
NO1 White
COM1 Black
NC1 Gray
Black
AL+ Red
Brown
Purple
Green
Orange
Blue
DESCRIPTION WIRE
Do not use
PowerIn
Lock
Alarm
Button
Sensor
Bell
In
Out
Ethernet
Power
Out
In
RedLED
Beep
Green
GND
WD1
WD0
GND
+12V
GND
Wiegand
485B
485A
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
RS485
Wiegand
+12V
BELL-
BELL+
SEN
AUX
GND
GND
BUT
N1O
COM1
N1C
AL-
AL+
{
{
{
{
{
{
{
{
{
{
{
{
{
RLED
BEEP
GLED
TXD
RXD
GND
RS232
Auxiliary
LED
GND
FR107
Diode
-
+
NC1
Do not reverse the polarities.
The system supports both and . The
(Normally Opened when powered) is connected with ' ' and ' ' terminals, and the
(Normally Closed when powered) is connected with ' ' and ' ' terminals. The power can be
shared with the lock or can be used separately for the lock, as shown in the example with NC
Lock below:
Normally Opened Lock Normally Closed Lock NO Lock
NO COM NC Lock
NC COM
AL-

Lock Relay Connection
Device Sharing Power with the Lock
9
AUX
GND
BELL-
Yellow
BELL+
SEN
GND Red
BUT
NO1 White
COM1 Black
NC1 Gray
Black
AL+
AL-
Red
Brown
Purple
Green
Orange
Blue
DESCRIPTION WIRE
Do not use
PowerIn
Lock
Alarm
Button
Sensor
Bell
In
Out
Ethernet
Power
Out
In
RedLED
Beep
Green
GND
WD1
WD0
GND
+12V
GND
Wiegand
485B
485A
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
RS485
Wiegand
+12V
BELL-
BELL+
SEN
AUX
GND
GND
BUT
N1O
COM1
N1C
AL-
AL+
{
{
{
{
{
{
{
{
{
{
{
{
{
RLED
BEEP
GLED
TXD
RXD
GND
RS232
Auxiliary
LED
BEEP Purple
GLED Gray
IWD1 Green
RLED Blue
+2V1Red
GND Black
IWD0 White
DESCRIPTION WIRE
COM1
FR107
Diode
GND
12V DC
1
12
1
7
Sensor
GND
GND
NC1
Normally Closed Lock
!Do not reverse the polarities.

Standalone Installation
Door Sensor
Electric Lock
ALARM
EXIT
No Touch
Exit Button
%
Ethernet
ZKBioSecurity
Doorbell
Card Reader
ProBio
Alarm
11
USB Disk
ZKBioSecurity
Download
Dynamic QR code
App Store
Google play
Emergency Button
RS485/ Wiegand
Output
Input
Output

Wiegand Output Connection
Do not use
?
GNDWD1 WD0
?
?
????
????
???
???
???
????
???
BEEP
1
0
+12V
GLED
WD
WD
GND
485B Yellow
485A Blue
GND Black
TXD Purple
GND Black
WD0 Green
WD1 White
RXD Gray
PowerIn
Lock
Alarm
Button
Sensor
Bell
In
Out
Ethernet
Power
Out
In
RedLED
Beep
Green
GND
WD1
WD0
GND
+12V
GND
Wiegand
485B
485A
RJ45-1
RJ45-2
RJ45-3
RJ45-6
IWD1
IWD0
RS485
Wiegand
+12V
BELL-
BELL+
SEN
AUX
GND
GND
BUT
N1O
COM1
N1C
AL-
AL+
{
{
{
{
{
{
{
{
{
{
{
{
{
RLED
BEEP
GLED
TXD
RXD
GND
Rs232
Auxiliary
LED
1
8
DESCRIPTION WIRE
10

Device Operation
12
User Registration
Method 1: Register on the device
Tap on to register a new user. The options include entering the User ID
and Name, setting User Role, registering Face, Card Number, Password, adding User Photo, and setting
Access Control role.
> [User Mgt.] > [New User]
When there is no Super Administrator set in the device, click on to enter the menu. Add a new user
and set the User Role to Super Admin. The system will request the Administrator’s verification before
entering the menu. It is recommended to register a Super Administrator initially for security purposes.
Method 2: Register on softwareZKBioSecurity
Refresh New Delete Export Search Control Set up View/Get Communication
Search
Search No device found? Download SearchTools to Local Disk
Searched devices count:1
Device Type Serial Number
Total Progress
IP Address
MAC Address Subnet Mask Gateway Address Serial Number Device Type Set Server Operations
IP Address
192.168.163.201 255.255.255.0 192.168.163 201.CJHC203336 ProBio Add
The current systen communication port is 6609, please make sure the device is set correctly.
Step 1
Step 2
Step 3
Device Name
Icon Type
Area
Add to Level
Clear Data in the Device when Adding
[Clear Data in the Device when Adding] will delete data in the device(except event
record), please use with caution!
Door
Area Name
OK Cancel
Step 4
1. Click to searchthedeviceonthe software.When an appropriate
Server Address and port is set on the device, the searched devices will be displayed automatically.
[Access]>[Device]>[Device]>[Search]
Please set the IP Address and Cloud Service Server Address in the menu option on the device.Comm.
Add
192.168.163.201

Ethernet and Cloud Server Settings
Access Control Settings
13
Eg: 192.168. .163163
Eg: 192.168. .1163 Eg: 108038741...
Eg: 6609
Device Operation
3. Click and fill in all the required fields to register a new user
in the software.
[Personnel] > [Person] > [New]
For more details, please refer the ZKBioSecurity User Manual.
4. Click to synchronize
all the data to the device including the new users.
[Access] > [Device] > [Control] > [Synchronize All Data to Devices]
2. Click in the operation column, a new window will pop-up. Select the Icon type, Area,
and Add to Level from each drop-down and click to add the device.
[Add]
[OK]
Click on to set the Server Address and Server Port, the IP
Address and Port Number of the server after the software is installed. Ifthe device communicates with
theServer successfully,the icon will bedisplayedin theupperright corner ofthe standbyinterface.
> [COMM.] > [Cloud Server Setting]
Click on to set the network parameters. If theTCP/IP communication of the
deviceis successful,the icon willbe displayedin theupper right cornerof thestandbyinterface.
> [COMM.] > [Ethernet]
Click on to enter the access control management interface and set the
relevant parameters of the access control.
> [Access Control]

14
QR Code as the Mobile Credential
Please set the IP Address and Cloud Service Server Address in the menu option on the device.COMM.
The device can recognize the QR code image on the ZKBioSecurity Mobile APP captured by the
QR code scanner, making it easy to access without contact.
1. Mobile APP Configuration
After downloading and installing the , the user needs to set the Server before login.
d. After the network is connected successfully, tap .[Save]
a. On the Server, choose to add
a registered A client.
[System] > [Authority Management] > [Client Register]
pp
b. Open the on the Smartphone. On the login screen, tap and type the
IP Address or the Domain Name of the Server, and its Port Number.
App [Server Setting]
c. Tap the QR Code icon to scan the QR code of the new client. After the client is identified
successfully, set the Client Name and tap .
App
[Testing Connection]
2. Employee Mobile Login
The Mobile Credential function is only valid when logging in as an employee ap on
Employee to switch to Employee Login screen. Employees can login with the Personnel
ID in and self-service password. The default self-
service password is
.T
[Personnel] > [Personnel] > [Person]
123456.
3. Scan the QR Code
Find the access control QR code on the ZKBioSecurity Mobile App. Show the QR code to the
QR code scanner of the device.The device prompts that the verification is successful.
2. When scanning, the QR code and the scanner must stay parallel at a distance of 15 to 30cm.
1. The user must have a card number registered in advance on the device or on the software.
Note:
Mobile Credential
For more details, please refer the .ZKBioSecurity Mobile APP User Manual
http://110.80.38.74
6609
4667D7
Mike
Eg: http://110.80.38.74
Eg: 6609
Device Operation

Copyright©2021 ZKTECO CO., LTD. All rights reserved.
ZKTeco Industrial Park, No.32, Industrial Road,
Tangxia Town, Dongguan, China.
Tel: +86 769-82109991
Fax: +86 755-89602394
www.zkteco.com
Other manuals for ProBio
2
Table of contents
Other ZKTeco Security System manuals

ZKTeco
ZKTeco X7 User manual

ZKTeco
ZKTeco OP-400 User manual

ZKTeco
ZKTeco FR1200 User manual

ZKTeco
ZKTeco G4 Pro Series User manual

ZKTeco
ZKTeco ZKRF10M User manual

ZKTeco
ZKTeco DM10 User manual

ZKTeco
ZKTeco SpeedFace Series User manual

ZKTeco
ZKTeco ProFace X User manual

ZKTeco
ZKTeco SF1008+ User manual

ZKTeco
ZKTeco FaceKiosk-H13 User manual