Βιομετρικός Ελεγκτής SA-X6
Ο βιομετρικός ελεγκτής SA-X6 υποστηρίζει κλειδαριές NO Lock & NC Lock.
Προσοχή: θα πρέπει παράλληλα με το φορτίο (κλειδαριά) να συνδεθεί μία δίοδος
FR107, όπως φαίνεται στο σχήμα για προστασία από EMF.
1. User management
1.1 Administration Operations
For the security the data, admin password is needed to operate the machine.
Register the admin fingerprint
Press [*]+[#]→Input [1234#]→register fingerprint 3 times (green light on and a
long buzz) →press [*] to exit (green light on and a long buzz)
Modify the admin fingerprint
Press [*]+[#]→Press admin finger print → press [8] (green light on and a long
buzz) →register fingerprint 3 times → press [*] to exit (green light on and a long
buzz)
1.2 Add/Edit a User -Προσθήκη/επεξεργασία Χρήστη
Each user can register 10 fingerprint and 1 card/Tag at most.
Press [*]+[#]→ press admin finger print → press [#]→ Input a new/ existing work
code (user ID 1-8) → [#]→ register user fingerprint 3 times (green light on and a
long buzz) OR register user CARD or TAG →press [#] continue to add new users
OR press [*] to escape (green light on and a long buzz).
Notice:
a. New user has to put work code (user ID), the machine will defultly edit the present
user if the number existed.
b. After the first fingerprint registered, same user's other fingerprints can be added,
10 pieces at most
c. If there is wrong action or repeat occurred suring register fingeprint/ cards,
machine's red light will be on along with short buzz 4 times, then green light will be
on. Continue to register without exit, no operation limits.
1.3 Register 8 group open password.
Device maximum support 8 group open door password, each password with 1 group
(range:1-8).
Press * + # -- Administrator finger--Press 3 input group number (1-8) ---input 4 digits
password # (repeat it 2 times) Press * exit.
1:How to delete single user?
Answers: press * # press administrator finger (Green light blink) press 2 (Green light
blink)=input staff's ID number ---press finger or punch RFID cards. press * exit.