• Leave the cleaning soluon to dissolve the scale deposit for about 15 minutes. Store your cleaning soluon in
a safe place or dispose of according to your local council regulaons, never pour it into the rainwater drainage
system or into sewers.
• Rinse the electrode using clean water and put back into posion.
• Open the isolaon valves (if applicable) and restart the chlorinator and the ltraon system.
* If you do not use a commercially available cleaning soluon, you can manufacture it yourself by
carefully mixing 1 volume of hydrochloric acid with 9 volumes of water (Warning: always pour the acid
into the water and not the opposite and wear suitable protecve equipment!).
Troubleshoong
EiXpert Text Displayed Possible causes Soluons
CLEANING The self-cleaning cycle is
automac; this message is
not an error code but an
informaon message.
• Wait for about 10 minutes and chlorine
producon will resume automacally at the
previously set level.
“Check
Salt”
warning
displayed
CHECK SALT • Salinity is under 3,000ppm.
• Pool water temperature too
low (< 18 °C, variable).
• Cell scaled up or worn.
• Add salt to the pool to keep the level at
4,000ppm. If you do not know the salt level
or how to test it, consult your pool care
professional.
• Display warning will come on when the
water is too cold. No acon required.
• Clean or replace the cell.
“Flow”
indicator
on
NO FLOW • Stop or failure of the
ltering pump.
• Presence of air or gas in the
cell (not lling with water).
• By-pass valves closed.
• Check lter, pump basket & skimmers and
clean them if necessary. Ensure all valves
are set for normal operaon.
• If using a variable speed pump ensure the
speed seng is high enough for adequate
ow through the cell.
• If sucon cleaner is connected to skimmer
check cleaner for blockages or restricon
of ow
CHECK PUMP • This message is displayed
alternately with "NO FLOW"
if the situaon connues.
• Check the pump connecon
into the power pack is
secure.
• Perform the same checks as above.
Note: that EiXpert has built in pump
protecon. This means that EiXpert will
supply power for 4 mins, if there is no ow
detected it will retry aer 20mins. It will
repeat this again and if sll no ow it will
enter into standby and require restarng.
All schedules will remain in memory.
CHECK CELL • Short-circuit in the cell or
cable disconnected/badly
connected.
• Worn electrode.
• Check the cell connecons.
• Replace the cell.
• Have the control box (electronic board
and transformer) checked by a qualied
technician if necessary.
OVERHEAT • Device internal temperature
over 70 °C.
• Device internal temperature
over 80 °C.
• The device reduces its producon to 50 %.
• Producon stops.
• Producon restarts automacally when the
temperature drops.
X• The device no longer stores
the me.
• Check the condion of the baery.
• Replace it if necessary (3 V baery, type
"CR2032").
==> If the problem continues contact your pool care professional.