4.2 Wintering
• During wintering it is recommended to rinse the peristal c tube using clean water by carrying out
manual priming (see §3.4).
• Then place the roller holder at 6 o’clock to facilitate restar ng.
• Remove the pH sensor from its holder and store it in its original bo le, or in a container lled with tap
water.
• Close o the sensor holder if necessary.
Always keep the sensor in water and protected from freezing.
5. Troubleshoo ng
5.1 Display of the regulator
Message Possible causes Solu ons
«Level» • Protector product container
empty
• Floater blocked
• Level sensor short circuited.
• Replace the corrector product container
• Check that the white oater on the suc on cane is in working
order
• Change the suc on cane
«OFA Alarm» First step in the over feed safety
system ac vated ( me > 75%) • Press to stop the alarm
• Check the sensor and/or the pool pH level
«OFA Stop» Second step in the over feed safety
system ac vated ( me = 100%) • Press to stop the alarm
• Check the sensor and/or the pool pH level
«OFA Check» pH sensor measurement test when
the «OFA Stop» was ac vated
during a previous ltering cycle.
• Wait for the end of the procedure (1 hour) then check the
sensor and/or the pool pH level.
«Flow» • Filtering stopped
• Incorrect connec on
• Start and/or check the ltering
• Check the electric connec ons
«Error» • Used Bu er solu on(s)
• pH sensor dirty
• Defec ve pH sensor
• Replace the bu er solu on(s)
• Clean the pH sensor using a 10% HCl solu on
• Replace the pH sensor
«Error
Parameter»
Se ng error
• Press to cancel the fault
• Replace the electronic card
5.2 Appliance malfunc ons
Malfunc on Possible causes Solu ons
The appliance
always displays a pH
value close to 7.0
Cable problem and/or BNC
connector problem
• Check that the connec on between the sensor and the
control box is not short circuited (between the cable’s
central core and the external shielding)
• Check that there is no humidity and/or condensa on at the
BNC connector level
The appliance
always displays an
unsuitable value
or the measure is
constantly unstable
• pH sensor connec on cable is
damaged
• There is an air bubble in the
pH sensor bulb
• The pH sensor is worn
• The pH sensor cable is too
close to an electric cable
causing disturbances
• The sensor is not correctly
ed on the piping.
• Check the cable and/or the BNC connector
• Posi on the pH sensor ver cally and shake gently so that
the air bubble rises to the top (sensor must be mounted
ver cally or at a 45° angle maximum, seer §2.4)
• Replace the pH sensor
• Reduce the distance between the appliance and the sensor
• Place the sensor in a more suitable loca on (see §2.2.1)