3M Aura 9310+Gen3 User manual

Product description
The 3M™Aura™Particulate Respirators 9300+Gen3
Series meet the requirements of European Standard
EN149:2001+A1:2009, filtering facepiece respirators for
useagainst particles. They provide effective respiratory
protection for use in industries where workers will be exposed
to solid (dust) particles and/or non-volatile liquid particles.
Applications
These respirators are suitable for use in concentrations
ofsolid (dust) particles and/or non-volatile liquid particles
upto the following limits:
Product
Product EN 149:2001+A1:2009
classification
Maximum
Workplace
Exposure
Limit (WEL)
9310+Gen3
9312+Gen3 FFP1 NR D 4
9320+Gen3
9322+Gen3 FFP2 NR D 12
9330+Gen3
9332+Gen3 FFP3 NR D 50
*Many countries apply Assigned Protection Factors (APFs) which reduce the
maximum concentrations of particles inwhich these products can be used.
Seenational regulations and EN 529:2005.
Respiratory protection is only effective if it is correctly
selected, fitted and wornthroughout the time when the
wearer is exposed to hazards.
Standards
Products are classified by filtering efficiency and maximum
total inward leakage performance (FFP1, FFP2 and FFP3),
alsoby usability and clogging resistance.
Performance tests in this standard include filter penetration;
extended exposure (loading) test; flammability; breathing
resistance and total inward leakage. Reusable products are
also subjected to cleaning, storage and mandatory clogging
resistance tests (clogging is optional for non-reusable
products). A full copy of EN 149:2001+A1:2009 can
bepurchased from your national standards body.
Filter penetration
The filter penetration, initial and after 120mg of loading with
both 120mg of NaCl* and Paraffin Oil, shall not exceed the
following limits:
EN 149:2001+A1:2009
classification
Maximum
Filter
Penetration
FFP1 NR D 20%
FFP2 NR D 6%
FFP3 NR D 1%
*Loading of NaCl may be stopped if filter penetration during loading is observed
to decrease.
Total inward leakage
Ten subjects perform five test exercises whilst wearing the
respirator. The total inward leakage inside of the respirator
due to face seal leakage, filter penetration and valve leakage
is measured for each subject exercise. The subject mean total
inward leakage for 8 out of 10 subjects shall not exceed the
following limits:
EN 149:2001+A1:2009
classification
Maximum
Total Inward
Leakage
FFP1 22%
FFP2 8%
FFP3 2%
3M™Aura™Particulate Respirators
9300+Gen3 Series
Technical Data Sheet
1

3M™Personal Safety Division |3M™Aura™Particulate Respirators 9300+Gen3 Series
Components and materials
The following materials are used in the production of the
3M™Aura™Particulate Respirators 9300+Gen3 Series:
Component Material
Straps (yellow for FFP1, blue
forFFP2 and red for FFP3)
Polyisoprene /
Polyester
Staples Steel
Nose foam Polyurethane
Nose clip Aluminum
Filter Polypropylene
Tabs Polypropylene
3M™Comfort Cool Flow™Valve Polypropylene /
Polyisoprene
Individual wrapper Polypropylene
These products do not contain components made from
natural rubber latex.
Typical weight
Product Typical
Weight
3M™Aura™Particulate
Respirator 9310+Gen3 11g
3M™Aura™Particulate
Respirator 9312+Gen3 15g
3M™Aura™Particulate
Respirator 9320+Gen3 11g
3M™Aura™Particulate
Respirator 9322+Gen3 15g
3M™Aura™Particulate
Respirator 9330+Gen3 11g
3M™Aura™Particulate
Respirator 9332+Gen3 15g
Breathing resistance
The breathing resistance of the respirator is tested during
inhalation and exhalation. Thebreathing resistance of the
respirators shall not exceed the following limits:
EN 149:2001
+A1:2009
classification
Maximum Breathing Resistance
Inhalation
at 30l/min
Inhalation
at 95l/min
Exhalation
at 160l/min
FFP1 0.6 mbar 2.1 mbar 3.0 mbar
FFP2 0.7 mbar 2.4 mbar 3.0 mbar
FFP3 1.0 mbar 3.0 mbar 3.0 mbar
Clogging
For single shift use respirators (NR), the clogging test
isoptional. For re-usable respirators (R) this test is mandatory.
The respirators are loaded with very high amount of Dolomite
dust which will tend to clog the filter. After loading with the
required amount of dust, the breathing resistance of the
respirators shall not exceed the following limits:
EN 149:2001
+A1:2009
classification
Maximum Breathing Resistance
Inhalation
at 95l/min
Exhalation
at 160l/min
FFP1
4.0 mbar
(valvedrespirator)
3.0 mbar
(unvalvedrespirator)
3.0 mbar
(valvedrespirator)
FFP2
5.0 mbar
(valvedrespirator)
4.0 mbar
(unvalvedrespirator)
3.0 mbar
(valvedrespirator)
FFP3
7.0 mbar
(valvedrespirator)
5.0 mbar
(unvalvedrespirator)
3.0 mbar
(valvedrespirator)
Flammability
Tested respirators are mounted on a metallic head which
rotates with a linear speed of 60mm/s. The respirators are
passed within 20mm of the tip of an 800°C (±50°C) propane
burner flame. The respirator shall not burn orcontinue to burn
within 5 seconds of removal from the flame.
2

3M™Personal Safety Division |3M™Aura™Particulate Respirators 9300+Gen3 Series
Storage and transportation
3M™Aura™Particulate Respirators 9300+Gen3 Series have
ashelf life of 5 years from date of manufacture. End of shelf
life is marked on the product packaging and upon the product.
Before initial use, always check that the product is within the
stated shelf life (use by date).
Product should be stored in clean, dry conditions within the
temperature range: – 20°C to + 25°C with a maximum relative
humidity of <80%. When storing or transporting the respirator,
remove bend in noseclip, align top and bottom panels together
before pushing the top panel flat. Store respirator inoriginal
packaging provided.
Warnings and use limitations
Always be sure that the complete product is:
ŔSuitable for the application;
ŔFitted correctly;
ŔWorn during all periods of exposure;
ŔReplaced when necessary.
Proper selection, training, use and appropriate maintenance
are essential in order for the product to help protect the
wearer from certain airborne contaminants. Failure to follow
all instructions on the use of these respiratory protection
products and/or failure to properly wear the complete
product during all periods of exposure may adversely affect
the wearer’s health, lead to severe or life threatening illness
orpermanent disability.
For suitability and proper use follow local regulations,
refer toall information supplied or contact a safety
professional/3M representative.
Before use, the wearer must be trained in use of the complete
product in accordance with applicable Health and Safety
standards/guidance.
These products do not contain components made from
natural rubber latex.
These products do not protect against gases/vapours.
Do not use in atmospheres containing less than 19.5% oxygen.
(3M definition. Individual countries may apply their own limits
on oxygen deficiency. Seek advice if in doubt).
Do not use for respiratory protection against atmospheric
contaminants/concentrations which are unknown
orimmediately dangerous to life and health (IDLH).
Do not use with beards or other facial hair that may inhibit
contact between the face and the product thus preventing
agood seal.
Leave the contaminated area immediately if:
ŔBreathing becomes difficult.
ŔDizziness or other distress occurs.
Discard and replace the respirator if it becomes damaged,
breathing resistance becomes excessive or at the end
oftheshift.
Do not clean, alter, modify or repair this device.
In case of intended use in explosive atmospheres, contact 3M.
Before initial use, always check that the product is within the
stated shelf life (use by date).
Fitting instructions
See Figure 1.
Before fitting device, ensure hands are clean.
All respirator components should be inspected for damage
prior to each use.
1. With reverse side up and using tabs, separate top
andbottom panels.
2. Pull chin and nose panel tabs until the noseclip bends
sothat the respirator forms a cup shape. Ensure both
panels are fully unfolded.
3. Whilst still holding the tabs, hold the respirator with
openside towards face and bring respirator to face.
4a. VALVED respirator – With one hand, hold the sides
ofthevalve to hold respirator position on face.
4b. UNVALVED respirator – Cup respirator in one hand
withopen side towards face.
5. With other hand, take each strap in turn and pull each
strap over your head.
6. Locate the upper strap across the crown of the head
and the lower strap below the ears. Straps must not
betwisted. Adjust top and bottom panels, using tabs,
foracomfortable fit. Ensure that panels are not folded
andthat tabs are folded flat.
7. Using both hands, mould noseclip to the shape of the
noseto ensure a close fit and good seal. Pinching the
noseclip using only one hand may result in less effective
respirator performance.
8. The seal of the respirator on the face should
befit-checked before entering the workplace.
Figure 1
3

Personal Safety Division
3M United Kingdom plc
3M Centre
Cain Road, Bracknell
Berkshire RG12 8HT
t: 0870 60 800 60
www.3M.eu/PPEsafety
Please recycle. Printed in the UK.
3Misatrademark of the 3M company. Used
under licence by 3M subsidiaries and affiliates.
© 3M 2017. All rights reserved. J379204
Important notice
The use of the 3M product described within this document assumes that the user has previous experience of this type of product and
that it will be used by a competent professional. Before any use of this product it is recommended to complete some trials tovalidate
theperformance of the product within its expected application.
All information and specification details contained within this document are inherent to this specific 3M product and would not be applied
toother products or environment. Any action or usage of this product made in violation of this document is at the risk of the user.
Compliance to the information and specification relative to the 3M product contained within this document does not exempt the user from
compliance with additional guidelines (safety rules, procedures).
Compliance to operational requirements especially in respect to the environment and usage of tools with this product must be observed.
The3M group (which cannot verify or control those elements) would not be held responsible for the consequences of any violation of these
rules which remain external to its decision and control.
Warranty conditions for 3M products are determined with the sales contract documents and with the mandatory and applicable clause,
excluding any other warranty or compensation.
3M™Personal Safety Division |3M™Aura™Particulate Respirators 9300+Gen3 Series
Fit check
1. Cover the front of the respirator with both hands
beingcareful not to disturb the fit of the respirator.
2a. UNVALVED respirator – EXHALE sharply.
2b. VALVED respirator – INHALE sharply.
3. If air leaks around the nose, re-adjust the noseclip
toeliminate leakage. Repeat the above fit check.
4. If air leaks at the respirator edges, work the straps
backalong the sides of the head to eliminate leakage.
Repeat the above fit check.
If you CANNOT achieve a proper fit DO NOT enter
thehazardous area. See your supervisor.
Users should be fit tested in accordance with
nationalrequirements.
For information regarding fit testing procedures,
pleasecontact 3M.
Disposal
Contaminated products should be disposed as hazardous
waste in accordance with national regulations.
Marking
NR = Non reusable
D = Meets the clogging requirements
End of Shelf Life. Date format: YYYY/MM/DD
Temperature Range
Maximum Relative Humidity
Name and address of Legal Manufacturer
Dispose of in accordance with local regulations
Approvals
These products are CE Marked to the requirements
ofCommunity Directive 89/686/EEC or European Regulation
(EU) 2016/425. The applicable legislation can be determined
by reviewing the Certificate and Declaration of Conformity
athttp://www.3M.com/Respiratory/certs
These products are type approved and audited annually
byBSI, Kitemark Court, Davy Avenue, Knowlhill, Milton
Keynes MK5 8PP, UK, Notified Body No. 0086.
Made in UK, in an ISO 9001:2008, ISO 14001:2004
andOHSAS 18001:2007 certified plant.
This manual suits for next models
6
Other 3M Respiratory Product manuals

3M
3M 7500 Series User manual

3M
3M 9502 User manual

3M
3M 8210 Instruction Manual

3M
3M Calibration Kit 529-04-48 User manual

3M
3M Versaflo TR-300-SG User manual

3M
3M Secure Click D3000 P100 Series User manual

3M
3M Versaflo User manual

3M
3M Versaflo TR-300 User manual

3M
3M 8212 User manual

3M
3M 9552N95 User manual