manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Switch
  8. •
  9. 3One data IES2312-8GT2GS2HS-2P48 User manual

3One data IES2312-8GT2GS2HS-2P48 User manual

IES2312-8GT2GS2HS-2P48
Unmanaged Industrial Ethernet
Switch Quick Installation Guide
3onedata Co., Ltd.
Address: 3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District,
Shenzhen
Website: www.3onedata.com
Te l : +86 0755-26702688
Fax: +86 0755-26703485
【
Package Checklist
】
Please check the integrity of package and accessories while
first using the switch.
1.
Industrial Ethernet switch
2.
DIN-Rail mounting attachment
3.
Certification
4.
Warranty card
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【
Product Overview】
This product is unmanaged DIN-Rail industrial Ethernet switch.
The model is: IES2312-8GT2GS2HS-2P48 (8 Gigabit copper
ports +2 Gigabit SFP slots + 2 2.5G SFP slots, 12~48VDC
redundant power supply)
【
Panel Design】
Top view, bottom view and rear view
Main view and right view
1. Terminal blocks for Power P1 input
2. Terminal blocks for Power P2 input
3. Terminal blocks for relay alarm output
4. DIP switch
5. Console port
6. Grounding screw
7. Wall-mounting location hole
8. DIN-Rail mounting kit
9. Power supply indicator (P1-P2)
10. Alarm indicator (ALM)
11. Running indicator (RUN)
12. Interface indicator (G1-G12)
13. 10/100/1000Base-T(X) copper port (G1-G8)
14. 2.5G SFP Slot (G9-G10), Gigabit SFP Slot
(G11-G12)
【
Mounting Dimension】
Unit: mm
Notice Before Mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【
DIN-Rail Mounting】
The product adopts 35mm standard DIN-Rail mounting which
is suitable for most industrial scenes, mounting steps as
follows:
Check if the DIN-Rail mounting kit is installed firmly.Step 1
Insert the bottom of DIN-Rail mounting kit (one sideStep 2
with spring support) into DIN-Rail, then insert the
top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Check and confirm the product is firmly installed onStep 3
DIN-Rail, then mounting ends.
【Disassembling DIN-Rail】
Power off device.Step 1
After lifting the device upward slightly, first shift outStep 2
the top of DIN-Rail mounting kit, and then shift out
the bottom of DIN-Rail, disassembling ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
then plug the power supply plug contact and power on.
Power OFF operation: First, remove the power plug,
then remove the wiring section of terminal block. Please
pay attention to the above operation sequence.
【Power Supply Connection】
The device provides 6-pin 5.08mm pitch power supply
terminal blocks and power supply occupies the left 4 pins. It
supports two independent DC power
supply systems, P1 and P2. Power supply
provides built-in 3A overcurrent protection,
and supports non-polarity and redundant
backup. Power supply range: 12~48VDC.
【Relay Connection】
This device provides 6-pin 5.08mm pitch
input terminal blocks, and the relay
occupies the right 2 pins. Relay terminals
are a set of normally open contacts of the
device alarm relay. They are open circuit in
the state of normal non alarm, closed when any alarm
information occurs. For example, they are closed when
powered off, and send out alarm. The switch supports 1 relay
alarm information output that supports DC power supply alarm
and port alarm information output. It can be connected to
alarm light, alarm buzzer or other switching value collecting
devices; it can timely inform operators when the alarm occurs.
【DIP Switch Settings】
The device provides 4-pin DIP switch for function
setting, in which “ON” is the enabled end. The
definitions of DIP switch are as follows:
DIP
Definition
Operation
1
Storm suppression
Set the DIP to “ON”
2
Jumbo frame
(
9600 Bytes
)
Set the DIP to “ON”
3
Relay alarm
Set the DIP to “ON”
4
IEEE802.3az Energy
Efficient
Set the DIP to “ON”
【Checking LED Indicator】
The device provides LED indicators to monitor its operating
status, which has simplified the overall troubleshooting
process. The function of each LED is described in the table
below:
LED
Indicate
Description
P1/P2
ON
Power supply is running normally
OFF
Power supply is disconnected or
LED
Indicate
Description
running abnormally
ALM
ON Power supply or port connection has
alarm
OFF Power supply and port has no alarm
or the alarm function is disabled.
RUN
ON
Device is not started or abnormal
OFF The device is powered off or the
device is abnormal.
Blinking
Blinking 1 time per second, the
device is running normally.
G1-G12
ON Ethernet port has established a valid
network connection.
Blinking Ethernet port is in an active network
status.
OFF Ethernet port has not established
valid network connection
【Specification】
Panel
Gigabit copper port
10/100/1000Base-T(X)
self-
adaption, RJ45,
Automatic Flow Control,
Full/Half Duplex Mode,
MDI/MDI-X Autotunning
Gigabit SFP slot 100/1000Base-X
self-adaption, SFP slot
2.5G SFP slot 100/1000/2.5GBase-X
self-adaption, SFP slot
Console port
Reserved
Alarm interface
6-
pin 5.08mm pitch terminal
blocks, including 2-
pin alarm
terminal blocks. It supports 1
channel relay alarm
information output, current
load capacity is 1A@30VDC
or 0.3A@125VAC
Indicator
Running Indicator, Alarm
Indicator, Power Supply
Indicator, Interface Indicator
Switch Property
Backplane bandwidth
30G
Packet buffer size
4Mbit
MAC address table
8K
Power Supply
Power input
12~48VDC, non-polarity,
redundant backup, built-in 3A
overcurrent protection
Access terminal blocks
6-
pin 5.08mm pitch terminal
blocks, power supply occupies
4 pins
Power Consumption
No-load
5.76W@48VDC
Full-load
12W@48VDC
Working Environment
Working temperature
-40~75℃
Storage temperature
-40~85℃
Working humidity
5%
~
95%(no condensation)
Protection grade
IP40 (metal shell)

Other 3One data Switch manuals

3One data IES2005 User manual

3One data

3One data IES2005 User manual

3One data IPS7112G-4GS-8POE User manual

3One data

3One data IPS7112G-4GS-8POE User manual

3One data IES1024 Series User manual

3One data

3One data IES1024 Series User manual

3One data ICS5400 Series User manual

3One data

3One data ICS5400 Series User manual

3One data IES2005-5T-P48 User manual

3One data

3One data IES2005-5T-P48 User manual

3One data IES615-2DI(3IN1) Series User manual

3One data

3One data IES615-2DI(3IN1) Series User manual

3One data IES615-2DI Series User manual

3One data

3One data IES615-2DI Series User manual

3One data IES3016L Series User manual

3One data

3One data IES3016L Series User manual

3One data IES6116 Series User manual

3One data

3One data IES6116 Series User manual

3One data IES5024-20F User manual

3One data

3One data IES5024-20F User manual

3One data ES2010G-2GS User manual

3One data

3One data ES2010G-2GS User manual

3One data IES215-1GX-4G User manual

3One data

3One data IES215-1GX-4G User manual

3One data ICS5530 Series User manual

3One data

3One data ICS5530 Series User manual

3One data TNS5000D Series User manual

3One data

3One data TNS5000D Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES5028G-4GS-8GC User manual

3One data

3One data IES5028G-4GS-8GC User manual

3One data PS5026G-2GS-24PoE Operating and maintenance instructions

3One data

3One data PS5026G-2GS-24PoE Operating and maintenance instructions

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES318 Series User manual

3One data

3One data IES318 Series User manual

3One data IES716-2GS User manual

3One data

3One data IES716-2GS User manual

3One data IPS215 Series User manual

3One data

3One data IPS215 Series User manual

3One data IES2100SL Series User manual

3One data

3One data IES2100SL Series User manual

3One data IES2016-16T Series User manual

3One data

3One data IES2016-16T Series User manual

3One data IES205 Manual

3One data

3One data IES205 Manual

Popular Switch manuals by other brands

NeoTech FSW-41HP quick start guide

NeoTech

NeoTech FSW-41HP quick start guide

KTI Networks KS-105F-T installation guide

KTI Networks

KTI Networks KS-105F-T installation guide

Ubiquiti UniFi USW-Pro-48-POE quick start guide

Ubiquiti

Ubiquiti UniFi USW-Pro-48-POE quick start guide

Titan Electronics USB-400-IR installation guide

Titan Electronics

Titan Electronics USB-400-IR installation guide

GRAS RA0056 instruction manual

GRAS

GRAS RA0056 instruction manual

Repotec RP-PG081W user manual

Repotec

Repotec RP-PG081W user manual

HBM MP85A operating manual

HBM

HBM MP85A operating manual

WEG CWBC9 18 Series instructions

WEG

WEG CWBC9 18 Series instructions

Belkin OmniView Professional Series installation guide

Belkin

Belkin OmniView Professional Series installation guide

Emos P5710TG manual

Emos

Emos P5710TG manual

Generac Power Systems EZ Switch RTS16EZA1 specification

Generac Power Systems

Generac Power Systems EZ Switch RTS16EZA1 specification

TRENDnet TFU-430 Guía De Instalación Rápida

TRENDnet

TRENDnet TFU-430 Guía De Instalación Rápida

3Com Baseline Switch 2824 3CBLUG24 user guide

3Com

3Com Baseline Switch 2824 3CBLUG24 user guide

Cisco ME 3400E quick start guide

Cisco

Cisco ME 3400E quick start guide

AbleNet Blue2 quick start guide

AbleNet

AbleNet Blue2 quick start guide

Bafo BF-4302 user manual

Bafo

Bafo BF-4302 user manual

SOR 1530 General instructions

SOR

SOR 1530 General instructions

Enterasys Vertical Horizon VHIM100-S1SFX 100BASE FX-SC Quick installation guide

Enterasys

Enterasys Vertical Horizon VHIM100-S1SFX 100BASE FX-SC Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.