manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Switch
  8. •
  9. 3One data ICS5400TSN-24GT16GS4XS-LN Series User manual

3One data ICS5400TSN-24GT16GS4XS-LN Series User manual

Other 3One data Switch manuals

3One data IES615-2DI Series User manual

3One data

3One data IES615-2DI Series User manual

3One data IES6100 Series User manual

3One data

3One data IES6100 Series User manual

3One data IES2305 Series User manual

3One data

3One data IES2305 Series User manual

3One data IES206 Series User manual

3One data

3One data IES206 Series User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data ICS5556 Series User manual

3One data

3One data ICS5556 Series User manual

3One data IPS215 Series User manual

3One data

3One data IPS215 Series User manual

3One data IPS716-2GC-4POE User manual

3One data

3One data IPS716-2GC-4POE User manual

3One data IES3016L Series User manual

3One data

3One data IES3016L Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data TNS5800D Series User manual

3One data

3One data TNS5800D Series User manual

3One data ES1008G-8POE-150W-P User manual

3One data

3One data ES1008G-8POE-150W-P User manual

3One data IES6316-8GT8GS-2P48 User manual

3One data

3One data IES6316-8GT8GS-2P48 User manual

3One data IES6220 Series User manual

3One data

3One data IES6220 Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES5028 Series User manual

3One data

3One data IES5028 Series User manual

3One data IES215-1GX-4G User manual

3One data

3One data IES215-1GX-4G User manual

3One data IES206G-2GS User manual

3One data

3One data IES206G-2GS User manual

3One data PS5010G-2GS-8PoE User manual

3One data

3One data PS5010G-2GS-8PoE User manual

3One data IES5028G Series User manual

3One data

3One data IES5028G Series User manual

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data

3One data IES2312-8GT2GS2HS-2P48 User manual

3One data IPS215-4POE User manual

3One data

3One data IPS215-4POE User manual

3One data IES716-2GS User manual

3One data

3One data IES716-2GS User manual

3One data IES5024-20F User manual

3One data

3One data IES5024-20F User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ICS5400TSN-24GT16GS4XS-LN
Series
Layer 3 Industrial Ethernet Switch
Quick Installation Guide
3onedata Co., Ltd.
Address: 3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District, Shenzhen
Website: www.3onedata.com
Te l : +86 0755-26702688
Fax: +86 0755-26703485
【Package Checklist】
Please check the integrity of package and accessories while
first using the switch.
1.
Switch ×1
2.
Mounting lug x2
3. AC
power line x2 (AC
product only)
4. Warranty card
5.
Certificate
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
This series are Rack-mounted layer 3 TSN industrial Ethernet
switches. Models as follows:
Model I. ICS5400TSN-24GT16GS4XS-LN-2LV (24 Gigabit
Copper Ports + 16 Gigabit SFP slots + 4 10G SFP+
slots, 12~55VDC redundant power supply)
Model II. ICS5400TSN-24GT16GS4XS-LN-2HV (24 Gigabit
copper ports + 16 Gigabit SFP slots + 4 10G SFP+
slots, 85~264VAC redundant power supply)
【Panel Design】
Model I: front view and rear view
Model II: front view and rear view
1. Lugs
2. Grounding screw (M4)
3. Relay alarm output interface
4. 100/1000Base-X Gigabit SFP slot (GS 1-16)
5. 10/100/1000Base-T(X) Gigabit copper port (GE
17-40)
6. 1G/2.5G/10GBase-X 10Gigabit SFP+ slot (XS 1-4)
7. CONSOLE port
8. Device indicators, from left to right in turn they are:
- Ethernet port indicator (G1-G40, X1-X4)
- Power indicator (P2-P1)
- Alarm indicator (ALM)
- Running indicator (RUN)
9. DC power supply input terminal blocks
10. AC power 2 supply input socket (PWR2)
11. AC power 1 supply input socket (PWR1)
【Mounting Dimension】
Unit: mm
Model I
Model II
Notice Before Mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Rack-mounted】
This product adopts 1U rack-mounting, mounting steps as
below:
Select the device mounting location to ensure
enough size.
Adopt 4 bolts to install the mounting lugs in the
device position as figure below.
Place the device in the rack; adopt 4 bolts to fix two
sides mounting lugs in the rack.
Check and confirm the product is mounted firmly on
the rack, mounting ends.
【Disassembling Device】
Power off the device.
Adopt screw driver to loosen the 4 bolts fixed on
the mounting lugs in the rack.
Shift out the device from rack, disassembling ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
then plug the power supply plug contact and power on.
Power switch “—” means power ON, “O” means power
OFF.
Power OFF operation: First, put the powers switch to
the "O" side and then disconnect the power supply.
Finally disconnect the connector between the device and
the power cord. Please notice the operation order above.
Please be aware of the power input range supported by
the device before powering on. Use the recommended
voltage of the device to avoid device damage.
【Power Supply Connection】
DC power supply (Model I)
Model I provides 5-pin 5.08mm pitch
terminal blocks and the built-in dual
power supply redundancy supports
DC power input. The power input
supports 1 single power supply input
or 2 power supply inputs at the same time; When two power
supply input at the same time, it supports redundant backup of
power supply. If one power supply fails, the device can still
work normally without interruption. Power supply supports
anti-reverse connection, which cannot power the device but
won’t damage it when it's reversely connected. The definitions
of power pin are shown in the left figure, and the power input
range is 24VDC/48VDC (12~55VDC).
AC power supply (Model II)
Model II provides 2 AC power sockets
with switch, PWR1 and PWR2, and
supports AC power supply input. The
power input supports 1 single power
supply input or 2 power supply inputs
at the same time; When two power supply input at the same
time, it supports redundant backup of power supply. If one
power supply fails, the device can still work normally without
interruption. Power supply input range: 110VAC/220VAC
(85~264VAC).
【Relay Connection】
Provide 3-pin 5.08mm pitch terminal block,
support 1 relay alarm output. In power off
situation, R- and R+ are a group of normally
closed contacts. After powered on, the relay is
open circuit in normal non-alarm state by default, closed when
any alarm information occurs. The relay supports power
supply alarm or network abnormality alarm. It can be
connected to alarm light or alarm buzzer or other switching
value collecting devices, which can timely inform operators
when the alarm occurs.
【Console Port Connection】
Provide 1 program debugging port based on
RS-232 serial port which can conduct device CLI
command management after connecting to PC.
The interface adopts RJ45 port, the RJ45 pin definitions are
as follows:
Pin No.
2
3
5
Definition
TXD
RXD
GND
【Checking LED Indicator】
The device provides LED indicators to monitor its operating
status, which has simplified the overall troubleshooting
process. The function of each LED is described in the table
below:
LED
Indicate
Description
P1/P2
ON
Power P1/2 is running normally
OFF Power P1/2 is disconnected or
running abnormally
ALM
ON
Power supply or port link has alarm
OFF
Power supply, port link without alarm
RUN
ON
The device is running abnormally
Blinking
Blinking 1 time per second, system
is running normally
OFF
The device is powered off or the
device is abnormal.
LINK
(G1-G40,
ON Ethernet port has established a valid
network connection
LED
Indicate
Description
X1-X4) Blinking
Ethernet port is in an active
network status
OFF
Ethernet port has not established
valid network connection
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device’s configuration interface via
browser is shown as below:
Configure the IP addresses of computer and the
device to the same network segment, and the
network between them can be mutually accessed.
Enter device’s IP address in the address bar of the
computer browser.
Enter device’s username in the login window as
shown below.
Click “OK” button to login to the WEB interface of
the device.
Note:
The default IP address of the device is “192.168.1.254”.
The default user name of the device is “admin”, no
password.
If the username or password is lost, user can restore it to
factory settings via management software; all modified
configurations will be cleared after restoring to factory
settings, so please backup configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【Specification】
Panel
Gigabit copper port 10/100/1000Base-T(X)
self-
adaption or forced mode,
RJ45, Automatic Flow Control,
Full/Half Duplex Mode,
MDI/MDI-X Autotunning
Gigabit SFP 100/1000Base-X self-adaption
or forced mode, SFP slot
10Gigabit SFP+ 1G/2.5G//10GBase-X
self-
adaption or forced mode,
SFP+ slot
Relay 1 relay alarm information output,
using 3-
pin 5.08mm pitch
terminal blocks, and the current
load capacity is 1A@30VDC or
0.3A@125VAC
CONSOLE port CLI command line management
port (RS-232), RJ45
Indicator Power indicator, alarm indicator,
running indicator, interface
indicator
Switch Property
Backplane bandwidth
160G
Packet buffer size
32Mbit
MAC Address Table
32K
Power Supply
Model I
24VDC/48VDC (12~55VDC),
dual power supply redundancy,
using 5-
pin 5.08mm pitch
terminal blocks, support
anti-reverse connection
Model II 110VAC/220VAC (85~264VAC),
dual power supply redundancy,
using AC socket with switch
Power Consumption
Model I No-load: 19.5W@24VDC
Full-load: 47.3W@24VDC
Working Environment
Working temperature
-40~75
℃
Storage temperature
-40~85℃
Working humidity
5%
~
95% (no condensation)
Protection grade
IP40 (metal shell)
【Disposal of Waste Electrical and Electronic
Equipment (WEEE 2012/19/EU)】
(Applicable in the EU-member states)
The crossed-out wheeled bin
symbol on the equipment or its
packaging indicates that the
product, at the end of its
service life, shall not be mixed
with unsorted municipal waste
but should be collected
separately, in accordance with
local laws and regulations.
A proper separate collection of
end-of-life equipment for the subsequent recycling, treatment
and environmentally compatible disposal, will help prevent
potential damage to the environment and human health,
facilitating the reuse, recycling and/or recovery of its
component materials.
Private users should contact their vendor or municipal waste
management service and ask for disposal information.
Professional users should contact their suppliers and check
the terms of their selling agreement.
This product must not be disposed of with other commercial
waste.
Users’ cooperation in the correct disposal of this product will
contribute to saving valuable resources and protecting the
environment.