ABB NE820 User manual

800xA Networks
NE820
User Manual
Power and productivity
for a better worldTM


800xA Networks
NE820
User Manual

NOTICE
This document contains information about one or more ABB products and may include a
description of or a reference to one or more standards that may be generally relevant to
the ABB products. The presence of any such description of a standard or reference to a
standard is not a representation that all of the ABB products referenced in this document
support all of the features of the described or referenced standard. In order to determine
the specic features supported by a particular ABB product, the reader should consult the
product specications for the particular ABB product.
ABB may have one or more patents or pending patent applications protecting the intellec-
tual property in the ABB products described in this document.
The information in this document is subject to change without notice and should not be
construed as a commitment by ABB. ABB assumes no responsibility for any errors that
may appear in this document.
In no event shall ABB be liable for direct, indirect, special, incidental or consequential
damages of any nature or kind arising from the use of this document, nor shall ABB be
liable for incidental or consequential damages arising from use of any software or hard-
ware described in this document.
This document and parts thereof must not be reproduced or copied without written
per-mission from ABB, and the contents thereof must not be imparted to a third party nor
used for any unauthorized purpose.
The software or hardware described in this document is furnished under a license and
may be used, copied, or disclosed only in accordance with the terms of such license. This
product meets the requirements specied in EMC Directive 2014/30/EU and in Low Volt-
age Directive 2014/35/EU.
TRADEMARKS
All rights to copyrights, registered trademarks, and trademarks reside with their respective
owners.
Copyright © 2003-2016 by ABB.
All rights reserved.
Release: December 2014
Document number: 3BSE080635

Table of Contents
Safety
Warning ..........................................................................................................................................7
Licensing Information ...................................................................................................................7
Section 1 - Managed Ethernet Switch
Housing......................................................................................................................9
3 Slot Enclosure.............................................................................................................................10
Power and CPU Module................................................................................................................11
Power and CPU ................................................................................................................12
Section 2 - Interface specications
Connection to Console Port ............................................................................................................14
Power Connection.........................................................................................................................17
I/O Connection ............................................................................................................................18
LED Indicators Power/CPU ........................................................................................................20
Section 3 - Interface Modules
Eight Copper Ports .....................................................................................................................23
Interface Specications ...............................................................................................................23
LED Indicators 8-Copper Ports................................................................................................24
4FG-4RG, 4 SFP Slots and 4-Gbit Copper Ports ......................................................................25
Interface Specications ...............................................................................................................25
LED indicators 4FG-4RG............................................................................................................26
Modular Transceivers ..................................................................................................................27
Mounting.................................................................................................................................27
Removal ...........................................................................................................................28
3BSE080635 5

Table of Contents
Wall Mounting .......................................................................................................................28
Earth Connection................................................................................................................................29
Cooling........................................................................................................................................29
Getting Started ................................................................................................................................31
Conguration .....................................................................................................................................32
Fibre Optic Handling.........................................................................................................................33
Maintenance............................................................................................................................33
Cleaning of the Optical Connectors ...................................................................................................33
Agency Approvals and Standards Compliance..................................................................................34
Notice: FCC Part 15.105.........................................................................................................34
Notice: EN 55022 ..................................................................................................................35
Safety Control Drawing ..................................................................................................................35
Safety Control Drawing ..................................................................................................................37
Type Tests and Environmental Conditions.......................................................................................39
Referring Documents ........................................................................................................................41
Cable Factory Reset on NE820 ....................................................................................................41
Proceed with Factory Reset ..................................................................................................41
Skip the Factory Reset .........................................................................................................42
6 3BSE080635

Safety
Warning
Do not look directly into bre optical bre port or any connected bre although
this unit is designed to meet the Class 1 Laser regulations.
When this unit is operated at an ambient temperature above 60°C, the External
Surface of Equipment may exceed Touch Temperature Limit according to EN/
IEC/UL 60950-1. To reduce the risk of re, use on No. 26 AWG or larger (e.g.,
24 AWG) UL listed or CSA certied telecommunication line cord.
Licensing Information
This device contains public available software which is under the GPL license. For
more information see legal.pdf included with all rmware releases. This product in-
cludes software developed by the OpenSSL Project for use in the OpenSSL Toolkit-
http://www.openssl.org.
3BSE080635 7

Licensing Information Safety
8 3BSE080635

Section 1 Managed Ethernet Switch
Section 1 Managed Ethernet Switch
NE820 is an Industrial switch made for harsh enviroments. The switch can be used in
either 100 Mbit or Gigabit networks due to our multi-rate SFP solution. Our unique
FRNT (Fast Recovery of Network Topology) technology is the fastest protocol on the
market to re-congure a network in the event of any link or hardware failure. That is
why NE820 is also used in safety critical applications such as tunnels, trafc signal
control and railway systems.
Installations in harsh environments and places with heavy electrical interference
require the use of a reliable media. NE820 provides a number of solutions using bre
optic transceivers. Multi- or singlemode transceivers can be used to build point-to-
point or redundant ring networks with ranges up to 120 km between each switch. Our
BIDI transceiver, which transmits and receives data on a single bre can be used in
applications where the number of bre cores are limited.
Real-time properties are implemented in the switch in order to achieve determinism
for real time critical applications. NE820 supports QoS (Quality of Service) with four
priority queues and strict priority scheduling as well as HoL (Head of Line Blocking
Prevention). All to assure that the data network is deterministic.
Housing
The back end holds a casted DIN-clip for stable mounting on a DIN-rail. Direct wall-
mount is also possible using the four brackets in each corner. The back end also holds
the earth connection. For detailed ground connection information, refer to section on
Earth Connection.
3BSE080635 9

3 Slot Enclosure
Figure 1. 3-Slot Enclosure
Section 1 Managed Ethernet Switch
10 3BSE080635
Specication
Dimension W x H x D 175 x 105 x 122 mm
(without connectors)
Weight 2.2 kg
Number of slots 3
Degree of protection IP40 according to EN 60529
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail or wall-mounted

Section 1 Managed Ethernet Switch
Power and CPU Module
Regardless of NE820 model, all units will be delivered with the power and CPU
interface in the slot on the far left. The power and CPU module holds a power
board and a CPU board. The isolated power supply has redundant power inputs and
allows for a wide operating voltage range (refer to Interface Modules). The digital
IO-port can be used for monitoring the unit. For more information, see ABB NEOS
Management guide.
The CPU module holds several interfaces. Three RJ-45 connectors with support for
Ethernet 1000BaseTX, a USB port for easy save/load of system conguration and a
console port. The console connector is a micro USB cable that connects to a FTDI
FT232R USB to serial converter internally. For drivers, please go to www.ftdichip.
com and download the appropriate VCP driver. For detailed information on LED
indicators, see section on LED indicators Power/CPU.
3BSE080635 11
Figure 2. Power and CPU Module

Section 1 Managed Ethernet Switch
Power and CPU
• Redundant power supply and alarm function
• Wide operating voltage range (16 VDC to 60 VDC)
• Digital IO for monitoring
• Console port for management using CLI
• USB port for easy save and load system conguration
• 3 x RJ-45 Ethernet 1000BaseTX connectors
• Status LED‘s
12 3BSE080635

Section 2 Interface specications
Section 2 Interface specications
3BSE080635 13
Power and CPU
Rated voltage 20 to 48 VDC
Operating voltage 16 to 60 VDC
Rated frequency DC
Polarity Reverse polarity pro-
tected
Redundant power input Yes
Redundant power input Yes
Isolation to All other
Connection Detachable screw
terminal
Connector size 0.2 – 2.5 mm2 (AWG
24 – 12)
Shielded cable Not required
Power
Rated voltage 20 to 48 VDC
Operating voltage 16 to 60 VDC
Rated current 0.93 (1.12*) A @ 20 VDC0.38
(0.45*) A @ 48 VDC

* With 500mA USB load
** External supply current capability for proper start-up
Connection to Console Port
Figure 3.Connection to Console Port
Section 2 Interface specications
14 3BSE080635
Inrush current 40 mA2s @ 20 VDC
257 mA2s @ 60 VDC
Startup current** 2x Rated current
Rated frequency DC
Polarity Reverse polarity protected
Redundant power input Yes
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Shielded cable Not required

Console
Electrical specication
Data rate
Circuit type
Maximum supply current
Isolation to
Galvanic connection to
Connection
USB 2.0 device
interface
High speed 480mbit/s
SELV
100 mA
All other except USB
USB
USB Micro-B connector
in device mode
USB
Electrical
specication
Data rate
Circuit type
Maximum
supply current
Isolation to
Connection
USB 2.0 host
interface
High speed
480mbit/s
SELV
500 mA
All other except
Console
USB receptacle
connector type A
Ethernet TX
Electrical
specication
Data rate
Duplex
Circuit type
IEEE std 802.3. 2005 Edition
10 Mbit/s, 100 Mbit/s, 1000
Mbit/s, manual or auto
Full or half, manual or auto
TNV-1
Up to 150 m with CAT5e cable
or better*
All other
Transmission
range
Isolation to
Section 2 Interface specications
3BSE080635 15

Section 2 Interface specications
16 3BSE080635
Conductive
housing
Yes Connection RJ-45 auto MDI/MDI-X
IO / Relay output
Shielded
cable Not required, except when
installedin Railway applications
as signallingand telecommuni-
cations apparatusand located
close to rails*.
Connect
resistance
30 W Conductive
housing
Yes
Isolation to All other Number of
ports
3
Connection Detachable screw
terminal * Note: Railway installation close to the rails.
To minimise the risk of interference, a shield-
ed cable is recommended when the cable
is located inside 3 m boundary to the rails
and connected to this port. The cable shield
should be properly connected (360°) to an
earthing point within 1 m from this port.
This earthing point should have a low imped-
ance connection to the conductive enclosure
of the apparatus cabinet, or similar, where
the unit is built-in. This conductive enclosure
should be connected to the earthing system
of an installation and may be directly connect-
ed to the protective earth.
Refer to Safety section for more information.
Connector size 0.2 – 2.5 mm2 (AWG
24 – 12)
Maximum
voltage/current
60 VDC / 80 mA
IO / Digital input
Voltage levels Vih > 8V Vil < 5V
Iin = 2.9mA @60V
Isolation to All other
Connection Detachable screw
terminal
Connector size 0.2 – 2.5 mm2 (AWG
24 – 12)
Maximum
voltage
60 VDC

Section 2 Interface specications
Figure 4. In/Out Directions Description
Power Connection
NE820 supports redundant power connection. The positive inputs are +DC1 and
+DC2, the negative input for both supplies are –COM. Connect the primary volt-
age (e.g. +24 VDC) to the +DC1 pin and return to one of the –COM pins on the
power input.
3BSE080635 17

Section 2 Interface specications
Figure 5. Power Connections
I/O Connection
The Status output is a potential free, opto-isolated normally closed solid-state relay.
This can be congured to monitor various alarm events within the NE820 unit, see
ABB NEOs Management Guide. An external load in series with an external voltage
source is required for proper functionality. For voltage/current ratings, see Interface
specications section.
Figure 6. I/O Connection
18 3BSE080635

LED Indicators Power/CPU
Figure 8. LED Indicators
Section 2 Interface specications
20 3BSE080635
Table of contents
Other ABB Switch manuals

ABB
ABB Sense7 Series User manual

ABB
ABB EDS500 Series Parts list manual

ABB
ABB Zenith ZTX Series User manual

ABB
ABB E 232 E-8/230N User manual

ABB
ABB TX series Instruction Manual

ABB
ABB Zenith ZTG T Series User manual

ABB
ABB NE802 User manual

ABB
ABB IS/S 8.1.1 User manual

ABB
ABB FAP 1011 User manual

ABB
ABB InLine II ZHBM-ITS Series User manual