ABB NE840 User manual

800xA Networks
NE840
User Manual


800xA Networks
NE840
User Manual

NOTICE
This document contains information about one or more ABB products and may include a
description of or a reference to one or more standards that may be generally relevant to
the ABB products. The presence of any such description of a standard or reference to a
standard is not a representation that all of the ABB products referenced in this document
support all of the features of the described or referenced standard. In order to determine
the specic features supported by a particular ABB product, the reader should consult the
product specications for the particular ABB product.
ABB may have one or more patents or pending patent applications protecting the
intellectual property in the ABB products described in this document.
The information in this document is subject to change without notice and should not be
construed as a commitment by ABB. ABB assumes no responsibility for any errors that
may appear in this document.
In no event shall ABB be liable for direct, indirect, special, incidental or consequential
damages of any nature or kind arising from the use of this document, nor shall ABB be
liable for incidental or consequential damages arising from use of any software or hard-
ware described in this document.
This document and parts thereof must not be reproduced or copied without written
permission from ABB, and the contents thereof must not be imparted to a third party nor
used for any unauthorized purpose.
The software or hardware described in this document is furnished under a license and
may be used, copied, or disclosed only in accordance with the terms of such license.
This product meets the requirements specied in EMC Directive 2014/30/EU and in Low
Voltage Directive 2014/35/EU.
TRADEMARKS
All rights to copyrights, registered trademarks, and trademarks reside with their respective
owners.
Copyright © 2003-2017 by ABB.
All rights reserved.
Release:
Document number:
April 2017
3BSE080639

Table of Contents
Safety
Warning .......................................................................................................................................... 7
Licensing Information .....................................................................................................................7
Section 1 - Industrial Routing Switch
Housing............................................................................................................................................9
Section 2 - Interface specications
Power Interface Specications ......................................................................................................11
Console ..............................................................................................................................12
USB....................................................................................................................................13
Network Ports......................................................................................................................14
TX Ports: Slot 1 and 2: 10/100/1000 Mbit/s, Slot 3: 10/100 Mbit/s ...................................15
SFP Slot ..............................................................................................................................16
I/O Connection ...................................................................................................................17
LED Indicators Power/CPU................................................................................................20
Modular Transceivers..........................................................................................................21
Mounting .......................................................................................................................................21
Rack Mounting....................................................................................................................21
Wall Mounting.....................................................................................................................22
Earth Connection............................................................................................................................22
Getting Started...............................................................................................................................23
Conguration.................................................................................................................................23
Fibre Optic Handling......................................................................................................................24
Maintenance .......................................................................................................................24
Cleaning of the Optical Connectors ...............................................................................................24
3BSE080639 5

Table of Contents
Agency Approvals and Standards Compliance .............................................................................. 25
Notice: FCC Part 15.105...........................................................................................................25
Safety Control Drawing ......................................................................................................................26
AC Power Supply ................................................................................................................................27
Type Tests and Environmental Conditions............................................................................................28
Referring Documents .........................................................................................................................31
Cable Factory Reset on NE840 ...........................................................................................................31
Proceed with Factory Reset ......................................................................................................31
Skip the Factory Reset .............................................................................................................32
6 3BSE080639

Safety
Warning
Do not look directly into bre optical bre port or any connected bre although
this unit is designed to meet the Class 1 Laser regulations.
To reduce the risk of re, use on No. 26 AWG or larger telecommunication line
cord.
Licensing Information
This device contains public available software which is under the GPL license. For
more information see legal.pdf included with all rmware releases. This product
includes software developed by the OpenSSL Project for use in the OpenSSL
Toolkit- http://www.openssl.org.
3BSE080639 7

Licensing Information Safety
8 3BSE080639

Section 1 Industrial Routing Switch
Section 1 Industrial Routing Switch
NE840 is a high performance layer 2 industrial Ethernet switch designed for high
network trafc applications. Various port congurations are available that can be
further customized with SFP transceivers. NE804 is powered by the ABB Network
Operating System (ABB NEOS).
NE840 is designed for 19” cabinet according to ETSI standard making it suitable for
use in control room networks as well as for cabinets installed along railway track side
or maritime installations. NE840 is designed to run efciently from an AC power
supply, the unit is also equipped with congurable I/O fault contact that make it ideal
for easy installation and monitoring in industrial applications.
NE840 Model
Housing
NE840 is designed for installation in 19” rack solutions according to ETSI
standard with a shallow depth of 240 mm as shown in Figure 1. NE840 can also be
wall mounted as an installation option.
3BSE080639 9
ABB Article
Number
Denomination Description
3BSE080211R1 NE840 8 x 10/100 Mbit/s, Ethernet TX, RJ-45
7 x 10/100/1000 Mbit/s, Gigabit Ethernet TX, RJ-45
4 x 100/1000 Mbit/s, pluggable connections
transceivers supported, Ethernet FX or TX SFP
AC power supply

Section 1 Industrial Routing Switch
Figure 1. Housing NE840
Specication
10 3BSE080639
Dimension W x H x D 480 x 43 x 258 mm
18,9 x 1,66 x 10,16”
Weight 3.8 kg
Degree of protection IP40 according to EN 60529
Cooling Convection
Mounting 19” rack or wall-mounted
RaMa 19P - 4PG - 7RG
Digital In-
Digital In+
Status-
Status+

RaMa 19P - 4PG - 7RG
Digital In-
Digital In+
Status-
Status+
I/O USB
Console
port
SFP slot, 100/1000 Mbit/s FX or
10/10/1000 Mbit/s TX ports
10/100 Mbit/s TX ports
Power
10/100/1000 Mbit/s
TX ports
Protective earth
Section 2 Interface specications
Section 2 Interface specications
Figure 2. Interface Specications
Power Interface Specications
Figure 3. Power Interface Specications
* External supply current capability for proper start-up
3BSE080639 11

RaMa 19P - 4PG - 7RG
Digital In-
Digital In+
Status-
Status+
Console
Section 2 Interface specications
Figure 4. Connection to Console Port
The console port shown in the Figure 4 can be used to connect to the CLI
(Command Line Interface). The console connector is a micro USB cable that
connects to a FTDI FT232R USB to serial converter internally. For drivers
please see www.ftdichip.com and download the appropriate VCP driver.
12 3BSE080639
* External supply current capability for proper start-up
Power
Rated Voltage 115 to 230 VAC
Operating voltage 90 to 264 VAC
Maximum nominal current consumption 350mA @ 115 VAC 60Hz
210mA @ 230 VAC 50 Hz
Inrush current 75mA2 @ 115 VAC
340mA2 @ 230 VAC
Rated frequency 50/60 Hz
Startup current* 2x nominal current
Polarity Not applicable
Redundant power input No
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Shielded cable Not required

Section 2 Interface specications
USB
Figure 5. USB
3BSE080639 13
Console
Electrical specication USB 2.0 device interface
Data rate High speed 480mbit/s
Circuit type SE LV
Maximum supply current 100 mA
Isolation to All other except USB
Galvanic connection to USB
Connection USB Micro-B connector in device mode
USB
Electrical specication USB 2.0 host interface
Data rate High speed 480mbit/s
Circuit type SE LV
Maximum supply current 500 mA
Isolation to All other except console
Connection USB receptacle connector type A
Conductive housing Yes

RaMa 19P - 4PG - 7RG
Digital In-
Digital In+
Status-
Status+
Slot 1 Slot 2 Slot 3
Network Ports
Figure 6. Network Ports
Section 2 Interface specications
14 3BSE080639
NE840
Slot 1
1 10/100/1000 Mbit/s, TX port
2 10/100/1000 Mbit/s, TX port
3 10/100/1000 Mbit/s, TX port
Slot 2
410/100/1000 Mbit/s, TX port
5 SFP slot
6 10/100/1000 Mbit/s, TX port
7 SFP slot
810/100/1000 Mbit/s, TX port
9 SFP slot
10 10/100/1000 Mbit/s, TX port
11 SFP slot

Ethernet TX
Electrical specication
Data rate
Duplex
Circuit type
Transmission range
Isolation to
Connection
Shielded cable
Slot 3
12
13
14
15
16
17
18
19
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
10/100 Mbit/s, TX port
Conductive housing
IEEE std 802.3. 2005 Edition
Slot 1 and 2: 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto
Slot 3: 10 Mbit/s, 100 Mbit/s manual or auto
Full or half, manual or auto
TNV-1
Up to 150 m with CAT5e cable or better
All other
RJ-45 auto MDI/MDI-X
Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close to
rails*
Yes
Section 2 Interface specications
TX Ports: Slot 1 and 2: 10/100/1000 Mbit/s, Slot 3: 10/100 Mbit/s
* Note: Railway installation close to the rails. To minimise the risk of interference, a shielded cable is recommended when
the cable is located inside 3 m boundary to the rails and connected to this port. The cable shield should be properly
connected (360°) to an earthing point within 1 m from this port. This earthing point should have a low impedance
connection to the conductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive
enclosure should be connected to the earthing system of an installation and may be directly connected to the
functional earth. Refer also to Safety section.
3BSE080639 15

Slot 3, 10/100 Mbit/s
Position Direction* Description
1 In/Out TD+
2 In/Out TD–
3 In/Out RD+
4 In/Out Not connected
5 In/Out Not connected
6 In/Out RD-
7 In/Out Not connected
8 In/Out Not connected
Shield In/Out Connected to
Functional earth
* Direction relative this unit.
+DC1
+DC2
COM
COM RSTP
FRNT
VPN
ON
DC1
DC2
1
2
1
1
10/100/1000
10/100/1000
10/100 Base-TX
POWER
CONSOLE
IO
2
3
4
5
6
7
8
2
3
4
1
5
6
7
8
2
3
4
Slot 1 and 2, 10/100/1000 Mbit/s:
Position Direction* Description
1 In/Out BI_DA+
2 In/Out BI_DA–
3 In/Out BI_DB+
4 In/Out BI_DC+
5 In/Out BI_DC-
6 In/Out BI_DB-
7 In/Out BI_DD+
8 In/Out BI_DD-
Shield In/Out Connected to
Functional earth
* Direction relative this unit.
Section 2 Interface specications
SFP Slot
Each SFP slot can hold one SFP transceiver for copper or bre cable. Fibre
transceivers distances range from 550 m (0.34 mi) to 120 km (74.6 mi). For
supported transceivers, see SFP data sheet.
Figure 8. SFP Slot
16 3BSE080639
Figure 7. TX Ports

RaMa 19P - 4PG - 7RG
Digital In-
Digital In+
Status-
Status+
Section 2 Interface specications
* 100 Mbit/s or 1000 Mbit/s transceiver supported.
I/O Connection
Figure 9. I/O Connection
The status output is a potential free, opto-isolated normally closed solid-state
relay. This can be congured to monitor various alarm events within the NE804
unit, see NEOS User Manual. An external load in series with an external voltage
source is required for proper functionality. For voltage/current ratings, see Interface
specications section.
The Digital in is an opto-isolated digital input which can be used to monitor external
events. For voltage/current ratings, see Interface specications section.
3BSE080639 17
SFP Ports
Optical/Electrical
specication
IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, 1000 Mbit/s
Duplex Full or half, manual or auto
Transmission range Depending on transceiver
Connection SFP slot holding bre transceiver or copper transceiver

Section 2 Interface specications
18 3BSE080639
IO / Relay Output
Connect resistance 30 W
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm2(AWG 24 – 12)
Maximum voltage/
current
60 VDC / 80 mA

Section 2 Interface specications
3BSE080639 19
IO / Digital Input
Voltage levels Vih > 8V Vil < 5V
Iin = 2.9mA @60V
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Maximum voltage/
current
60 VDC

LED Indicators Power/CPU
Section 2 Interface specications
20 3BSE080639
LED Status Description
ON OFF Unit has no power
GREEN All OK, no alarm condition
RED Alarm condition, or until unit has started up. (Alarm
conditions are congurable, refer to NEOS User Manual.
BLINK Location indicator Here I am. Activated when connected to
IPCong Tool, or upon request from Web or CLI.
DC1 OFF Unit has no power
GREEN Power OK on DC1
RED +DC1 input voltage is below operating voltage limit
DC2 OFF Unit has no power
GREEN Power OK on DC2
RED +DC2 input voltage is below operating voltage limit
AC1 OFF Unit has no power
GREEN Power OK on AC1
FRNT OFF FRNT disabled
GREEN FRNT OK
RED FRNT Error
BLINK Unit congured as FRNT Focal Point
RSTP OFF RSTP disabled
GREEN RSTP enabled
BLINK Unit elected as RSTP/STP root switch
USR1 Congurable, see WEOS User Manual
OFF No link
GREEN Link established
GREEN FLASH Data trafc indication
YELLOW Port alarm and no link. Or if FRNT or RSTP mode, port is blocked
TX/FX ports
Table of contents
Other ABB Switch manuals

ABB
ABB OT16F3 User manual

ABB
ABB UniSec SDS Operating and maintenance instructions

ABB
ABB 3299A-A02100 x Setup guide

ABB
ABB EDS500 Series User manual

ABB
ABB TruONE ATS OXB250E3S3QT User manual

ABB
ABB FIP1001 User manual

ABB
ABB ST-E Series User manual

ABB
ABB DTW User guide

ABB
ABB SACE Tmax XT2 User manual

ABB
ABB SSM/A User manual

ABB
ABB HD4 Series Quick guide

ABB
ABB PS Tango 3299A-A22100 Operation manual

ABB
ABB E 232 E-230N User manual

ABB
ABB Sense7 Series User manual

ABB
ABB NAL Series User manual

ABB
ABB Zenith ZTX Series User manual

ABB
ABB Zenith ZTX Series User manual

ABB
ABB OTM_C Series User guide

ABB
ABB DWTL1 User manual

ABB
ABB TL Series User manual