ACO INSPIRO+audio User manual

INSPIRO+audio DIGITAL DOOR PHONE PANEL OPERATION MANUAL
IMPORTANT! When disinfecting panels made of stainless steel, use only alcohol-based cleaners. All
types of chlorides (which are present in the composition of common cleaners) are harmful to the steel
surface, because they abrade its natural protective coating and increase the risk of corrosion marks.
62-002 Suchy Las, ul. Diamentowa 7, tel./ fax +48 61 843 93 72
www.aco.com.pl

DISPOSAL OF WASTE ELECTRICAL EQUIPMENT
Do not dispose of waste electrical equipment with other (household / municipal) waste types. Dispose of it separately as permitted by
law. Consult the authority of jurisdiction or licensed waste recycling service providers. Directive 2002/96/EC of 27/01/2003
MOUNTING THE PANEL
The device is meant to be installed on a building wall (entrance enclosure, vestibule, shielded wall,
Eastern wall, etc.), in order to minimise the effects of adverse weather conditions. We recommend
installing the panel approx. 1.35 m above the ground.
Install the flush mounting box using wall plugs and plaster in the appropriate wall slot so that the front
edge is in line with the wall’s surface.
CAUTION! To ensure proper operation and safety of use, provide the panel (set in its metal frame) with
protective earth bonding by connecting the terminal on the housing with the appropriate earthing
system (PE).
Connect the panel to the entrance door electric strike and its power with a 1 mm2 core cable (e.g.
LY1.0). The cable should be no longer than 7 m for the electric strike connection and no longer than
15 m for the power supply connection! An inadequate power supply rating, wiring cores of insufficient
sizes and excessive length of interconnecting wiring (resulting in voltage drops) may interfere with
proper operation (including the “humming” noise in the audio line or inadvertent triggering of the reset
system, especially when releasing the electric strike). Connect the +11.5V AC power to the +12V~
terminals; if 15V DC power is used, connect it to these terminals: +DC (+ELOCK) and GND (LINE-).
If a polarity-insensitive electric strike is installed, connect the wiring to the ELOCK terminals in any
order. If a fail-safe (NO) electric strike is installed, connect jumper Z13 (below the resistor on the left-
hand side of the PCB)!
For a fail-safe (NO) electric strike, the ELOC output is live depending on the power adapter or voltage
transformer type; use a compatible fail-safe (NO) electric strike. An optional MOD-DC-12V module is
available to feed 12V DC to a fail-safe (NO) electric strike when the DES is fed by an 15V DC power
supply or a voltage transformer. The additional relay OUTPUT terminal (Master only) can be wired to
control an additional entrance gate (by factory default) with a code keypad (with “the double Key button
press”) and button F2 of an uniphone. The live voltage time and functions of the OUTPUT terminal can
be configured in Program 18, Port 2 (as in the CND-I/O module).
Solder all wiring connections.
Connect the following wires to the panel:
2 x 1mm2 cable to power the panel
2 x 1mm2 cable: electric strike control;
2 x 0.5mm2: the DES output wiring to connect uniphones;
1 cable wire with yellow-and-green insulation – to connect the ground of the housing.
CONNECTION DIAGRAM FOR A SINGLE INSPIRO+AUDIO PANEL

CONNECTION DIAGRAM FOR MULTIPLE INSPIRO+AUDIO PANELS
UNIPHONE MOUNTING & WIRING
Install the uniphones as specified in their original manuals. Wire the equipment while setting the proper
address in the uniphone decoder; wire the “LINE” panels with proper polarity.
VOLUME SETTING
Set the volume as follows once the uniphone is connected properly:
- the “MIC” potentiometer is used for adjusting the sensitivity of the panel microphone
- the “SPK” potentiometer sets the speaker volume
- the “SOUNDS” potentiometer sets the panel sound output volume
Having set the values, operate the “BALANCE” potentiometer to find the points of excitation of the
speaker (indicated by squeaking sounds); next, adjust the potentiometer halfway between these points.
OPERATION
When in standby, the display shows the “Intro” message (which reads “aco” by default). The “Intro”
message contents are freely configurable. The default range of dialled numbers is 1 to 255, with each
value mapped directly to the physical addresses configured in the inside units (the software
configuration tool permits any dialled number range between 0 and 999999 and a free assignment of
each number to the inside unit address, or to restrict the range of supported inside units). Dialling is
done by inputting the apartment number with the keypad; if the optional 230E module is installed, select
the apartment number entry with the arrow buttons, followed pressing the Doorbell button. After approx.
3 s the receiver in the selected apartment will start ringing. If the dialled call is received in the dialling
mode, it is possible to hold a voice conversation and unlock the door electric strike. Opening the door
electric strike by inputting an apartment code: input the apartment number, confirm with the Key button
and follow with the 4-digit apartment code mapped to the input apartment number. In order to print the
full table of user codes or ready business cards for tenants together with the instructions for use, use
the "ACO Code Generator" available at www.aco.com.pl in the user area ("download"). For each
"Master" control panel, the code table is factory-set on the back of the device as a 4-digit number, and
for "Slave" devices, enter the same table as in "Master". Opening the door electric strike with one of
the five building administrator access codes: press the Key button and follow by inputting the six-digit
code. The building administrator access codes are intended for use by building administration and
maintenance personnel, e.g. maintenance technicians, the janitor, postmen, etc. The wired door
electric strike can also be unlocked by shorting the additional INPUT to ground. If a proximity reader
(ACC) is wired, the door electric strike is unlocked with the proximity card or keyfob (paired with the
DES and issued to e.g. the tenants, the building administration staff, or the DES installer). An attempt
of entry with a proximity card or keyfob which has not been paired will result with three loud beeps from

the DES speaker. When the door electric strike is unlocked, the display shows the following text string:
“Enter!”. The OUTPUT (“Master” only) is activated using the F2 button on the inside unit (during a
dialled call) or entering a valid access code; this requires pressing the Key button twice before the
access code is entered, not unlike in the regular door electric strike unlock procedure. For devices with
ACC, the 2nd output is triggered by pressing the Key button and using a paired proximity card or keyfob.
As long as the 2nd output remains triggered, the display shows the following text string: “Enter!”.
If working with Module 4 of the SW4S-DIN zones (1020 apartments), the appropriate option should be
set in the software (the mounting and installation details are found in the extended manual).
PROGRAMMING
To enter the installer menu: press the "key" button and within 5 seconds enter "1507xxxx", where
"xxxx" is the 4-digit Installer Password: at the factory these are the last 4 digits of the serial number
available on the sticker on the electronics board. The password should be changed to your own! (enter
the current password in menu 7 and then the new one). NOTE: In older panels (up to K-14), the factory
default installer password is "0000". The installer menu is confirmed by a beep, the software version
appears on the display and then program No. 0: "Open". Use the "2" up and "8" down buttons to move
through the Menu. To enter the currently displayed menu and the values entered, confirm with the "Key"
button. In installer mode it is possible to reset (restart) the panel by pressing buttons 7 and 9
simultaneously. When exiting the installer menu (by pressing "#"), the current temperature inside the
panel is displayed.
INSTALLER MENU ITEM DESCRIPTION
SERVICE-MODE ELECTRIC
STRIKE RELEASE
ENTERS THE APARTMENT
CODE SETTING MODE
CHANGING 5 ADMIN CODES,
ADDING ADMIN
CARD/KEYFOB
SETTING THE NUMBER OF
CALL RINGS;
ENABLE/DISABLE VOICE
DIALLING OF APARTMENTS
ENABLE/DISABLE THE
DOORBELL TINKLING AT THE
APARTMENT ONCE THE DOOR
ELECTRIC STRIKE IS
RELEASED
SETTING ONE OF THE FOUR
RING TONES
SETTING THE TIME TO LOCK
THE ELECTRIC STRIKE ONCE
RELEASED
CHANGING INSTALLER
PASSWORD
ADDING INSTALLER
CARD/KEYFOB
DISPLAYS THE CARDS PAIRED
WITH APARTMENTS
OPENS THE ACCESS CODE
TABLE INPUT MODE
ENABLE/DISABLE FAIL-SAFE
(NO) ELECTRIC STRIKE
ENABLE/DISABLE RESETTING
TO DEFAULT SETTINGS
ENTERS THE MODE OF
PAIRING PROXIMITY CARDS
AND KEYFOBS WITH AN ACC
PROXIMITY READER
ENTERS THE PROGRAMMING
MODE TO PAIR TENANT
NAMES TO KEYPAD BUTTONS
2, 6, 10NP (in Zone 1 only)
SETTING THE DOOR
ELECTRIC STRIKE RELEASE
DELAY AFTER MAKING THE
INPUT TERMINAL
SETTING THE DELAY TO
DISPLAY THE “CALL
SERVICE” MESSAGE
TRIGGER APARTMENT
CALLBACK
IN THE INSTALLER MODE
(THE PERMITTED
APARTMENT NO. RANGE)
TRIGGER APARTMENT
CALLBACK IN THE SERVICE
MODE (FROM A SPECIFIC
APARTMENT)
SEARCHES FOR UNIPHONES
WITH FAULTS OR NOT
PROPERLY REPLACED
HANDSETS
RUNS A LINE TEST TO CHECK
THE WIRED UNITS FOR
FAULTS
CAUTION! Accessing the full configuration requires the software configuration tool (“x700”) which can be downloaded for free from
www.aco.com.pl. The panel can be interfaced with a PC laptop with an optional CDN-USB data cable (which is purchased separately).
The website Downloads section also includes the full operating manual for the CDNP7ACC and INSPIRO+, complete with a
troubleshooting guide for most common problems. IU0302enVG.2206
Rings
OpInf
Tones
LTime
Fobs
Table
ReEL
RstLo
M-ACC
M-xNP
CaSrv
InsCa
SrvCa
LTest
PIN
Searc
IPass
Delay
Open
AKey
Other ACO Intercom System manuals

ACO
ACO FAM-P Installation instructions

ACO
ACO COMO-PRO-V Series User manual

ACO
ACO INS-UP 720B User manual

ACO
ACO MOD-SPK-PRO User manual

ACO
ACO CDNP6ACC User manual

ACO
ACO INS-UA720M User manual

ACO
ACO CDNP7ACC User manual

ACO
ACO INS-UC 720M User manual

ACO
ACO CDNP6ACC Installation instructions

ACO
ACO FAM-P Series User manual

ACO
ACO COMO-PRO-POST-A1 Series User manual

ACO
ACO CDNP7ACC User manual

ACO
ACO INSPIRO 4 Series User manual

ACO
ACO COMO-PRO User manual

ACO
ACO INSPIRO 1 Series User manual

ACO
ACO CDNP6ACC User manual

ACO
ACO Familio PRO User manual

ACO
ACO FAM-PV Series Installation instructions

ACO
ACO FAM-P Series User manual

ACO
ACO GLASS-IP-7 User guide