ADE M601020 User manual

M601020-210322-Rev009-UM-e
Operating Manual
Class III Approved Scales
Electronic Bed Scale
M601020

2 M601020-210322-Rev00 -UM-e
Content
Introduction ............................................................................................................................................ 3
Assembly and set up ............................................................................................................................. 3
Scope of delivery .................................................................................................................. 3
Assembly............................................................................................................................... 3
Po er supply ........................................................................................................................ 3
Replacing the rechargeable battery ................................................................................... 4
Tips for handling the batteries ............................................................................................ 4
Quality features ...................................................................................................................................... 4
Display .................................................................................................................................................... 5
Description ............................................................................................................................ 5
Connecting additional devices ........................................................................................... 5
Housing and connections ................................................................................................... 6
Safety ...................................................................................................................................................... 6
Settings ................................................................................................................................................... 6
Setting date and time ........................................................................................................... 7
Operation ................................................................................................................................................ 7
Modes of operation .............................................................................................................. 7
Before eighing ................................................................................................................... 7
Weighing ............................................................................................................................... 8
Tare function ......................................................................................................................... 8
Hold function ........................................................................................................................ 8
Determining the Body Mass Index (BMI) ...........................................................................
Evaluating Body Mass Index ...............................................................................................
Print out a record .................................................................................................................
Care, servicing and recalibration ......................................................................................................... 9
Cleaning ................................................................................................................................
Error messages ....................................................................................................................
Waste disposal ................................................................................................................... 10
Storage and transport conditions .................................................................................... 10
Warranty .............................................................................................................................. 10
Recalibration ....................................................................................................................... 10
Technical specifications ..................................................................................................................... 11
Conformity declaration ....................................................................................................................... 12

M601020-210322-Rev00 -UM-e 3
Introduction
This symbol means: "Consult operating instructions". To achieve accurate results, read the
instructions for use carefully before use and follow all instructions provided therein. Keep the
instructions for use for future reference.
Your ADE electronic bed scale is a quality, sturdy and durable product manufactured under the high standards
and regulations for calibrated class III scales in accordance with national regulation in Germany. The scale is
designed and manufactured for the daily practice in hospitals and dialysis centres.
ADE instruction manuals have been prepared to provide the user with all the necessary knowledge about the
safe use of ADE scales and their related accessory equipment.
For further questions about how to use the products or about this or other service manuals, feel free to contact
your local ADE representative or visit our web page at www.ade-hamburg.de
Assembly and set up
The ADE bed scale is supplied in a fully assembled condition. Please insure that your scale is being placed
vibration-free at a dry place. Dismantle packaging and foil carefully and remove the transport securing devic-
es. Place the weighing platforms on a plain, dry and level surface before the weighing procedure.
Scope of delivery
– 2 Weighing platforms
– Connection cable between weighing platforms
– Indicator incl. connection cable
– Mounting Device for the indicator
– Mains adapter
– Operating Manual including Certificate of Conformity
Assembly
Dismantle packaging and foil carefully. Weighing platforms are equipped with castors and a handle for easy
transport.
(1) Move the scale to the place of use.
(2) Connect both platforms to each other with the connecting cable.
(3) Connect the indicator with the corresponding cable to the jack connector at one of the weighing platforms.
(4) Connect the attached mains adapter to the indicator.
(5) Afterwards connect the mains adapter to the socket. The rechargeable batteries need 24 hours power
supply to achieve full battery load.
(6) Start the scale by pressing the ON key.
(7) The scale is ready to use
(8) Follow the steps under the chapter “Operations”.
Po er supply
Power is supplied either by the rechargeable battery in the display unit or by the mains power via the supplied
power unit. The imprinted voltage value at the mains adapter must match the mains voltage at the place of
use. Connect the mains cable to the indicator and to a socket.
The wall socket must be located near to the unit and be easily accessible. Please use only the mains adapter
supplied by ADE. The mains adapter is charging the battery pack during normal operation.

4 M601020-210322-Rev00 -UM-e
When the battery is being charged for the first time a sufficient charging period of approx. 24 hours is neces-
sary to achieve a full battery load.
If the unit is in battery mode and the display indicates – Lo, the battery needed to be recharged with the mains
adapter. For a full battery load a charging period of 12-16 hours is required with the scale being switched off.
If–Lo still appears at the display inform your service partner.
Replacing the rechargeable battery
The battery compartment is located on the front of the unit.
1) Open the battery compartment.
2) Remove the battery cables carefully from the housing, connect the wires (red to red, black to black) and
insert the battery into the housing.
3) Close the battery compartment again.
Only use original rechargeable batteries and charger units from ADE. The warranty does not cover any dam-
age caused by using other types of batteries or charger units.
Tips for handling the batteries
The life of a battery depends essentially on the load, frequency of use, temperatures, settings and the acces-
sories used.
– New batteries or batteries that have been stored for long periods require a longer charging period.
– Charge the batteries at room temperature.
– Never expose the batteries to temperatures below -10°C (14°F) or above 45°C (113°F).
– Rechargeable batteries lose their charging capacity over the time and require a longer charging period
the older they are. If the battery performance drops considerably, then it is time to replace the battery.
– New batteries are supplied in partial charged condition. Batteries achieve their full capacity after several
complete charge and discharge cycles.
– Do not throw old rechargeable batteries into the domestic waste. Ensure that the valid legal and munici-
pal regulations of your country are being followed.
– Never dispose of batteries in fire as they can leak or explode!
Quality features
ADE products correspond to the applicable EC Directives and European standards to manufacture
and distribute world-wide medical devices as per the latest technical standards ensuring a long life
time and continuous reliability.
This symbol stands for compliance of the European Directive covering medical
devices and declares the conformity as per the Medical Device Law..
Approved scales classes III respecting the standards of the European guideline
covering approved scales are carrying this sign.
Scales carrying this symbol are approved and accredited within the European
Community and fulfils first class demands for calibrated scales.
Products carrying this symbol meet the requirements as per:
The valid EC Directive for non automatic scales
in the latest version.
M21

M601020-210322-Rev00 -UM-e 5
Display
Description
pic. 1-1 Indicator and operating panel
No.
Name Description
1 Display LCD display for weight, mode, settings and configuration information.
2 Battery charge level Status of the battery charge level.
3 Switching points 1 & 2 In program mode: Status indicator for switching points 1 & 2.
4 BMI status indicator
(HI, OK, LO) Status of the automatic BMI (Body Mass Index) evaluation.
5 Net status indicator LCD on - net weight is being displayed.
LCD off – gross weight is being displayed.
6 Status indicator The scale is at zero level.
7 Hold – button Activates the hold function.
8 On/off, zero – button On and off switch and re-set of the display
Tare- button Activate/ deactivate the tare function.
10 Preset tare – button Press briefly to access the tare function.
Press for a long period to enter and save the tare value.
11 BMI – Button Enter to proceed with BMI mode.
12 Units – Button Switch button between primary and secondary units. Not available for CE
approved class III scales
13 Number pad
Figures 0- , Clear, Enter and Navigation functions: Key 6 menu direction
to the right; Key 4 menu direction to the left; Key 8 menu direction down;
Key 2 menu direction up. For better understanding see Pic. 1.1 the blue
arrows. Used to navigate through menus, to select numerical values and
to increase or lower the value.
Special function:
"0" key
In weight mode, you can change between gross and net weight using
figure "0" (if any weight have been tared off).
"Enter" key Function in weight mode: "Print" if printer has been connected.
14 Standstill status indica-
tor :
The scale is at a standstill, meaning the weight is stable and no
movement is on the platform. This is a mandatory precondition for func-
tions such as resetting, printing and taring).
If the LCD is not displayed: The scale is not in a the standstill mode
15 “Hold” If displayed is the hold function is activated
16 “kg” If displayed is the weight is displayed in kilograms
“g” If displayed is the weight is displayed in grams
Connecting additional devices
Printer, PC or remote-display could be connected by the RS-232 interface. For connection of additional devic-
es kindly ask your local representative or authorized ADE dealer for further instructions.
16
15
14
1
2
3
4
5
6
7
8
10
11
12
13

6 M601020-210322-Rev00 -UM-e
Housing and connections
The connections to mains adapter, serial port and to the load cells are located at the back of the ADE display.
The set-up switch to start the configuration mode is underneath the housing. It is protected by a cover plate
and secured by a screw (not shown in Fig. 2-1).
Do not use the set-up button, as other ise calibration ill be lost. This procedure is only al-
lo ed by authorized service personnel appointed by ADE (GmbH & Co.). Any unauthorized ma-
nipulations made to the configuration mode ill affect the arranty agreement.
Safety
The ADE-display unit (MAK) corresponds to the latest state of the art technology and complies with standard
regulations and directives. Kindly follow the safety instructions in this operating manual, the country-specific
installation standards as well as the applicable safety conditions and accident prevention regulations in all
aspects. Electronic medical devices are restricted to special safety regulations in respect of their electromag-
netic compatibility. For positioning and operation, follow the instructions of this operation manual.
– Portable and mobile HF-communication systems may influence electronic medical devices.
– Make sure that the mains cable does not pose any potential trip hazard.
– Do not drop the weighing bridges/shoes or subject them to violent shocks.
– Do not operate the unit in hazardous or unstable conditions.
– Do not dip or submerge the unit into water or other liquids.
– Have all repairs and calibration carried out by professional personnel authorised by ADE.
– Set up the unit as far away as possible from equipment that generates electromagnetic or other interfer-
ence.
– Only use original rechargeable batteries and mains adapter from ADE. The warranty does not cover any
damage caused by using other types of batteries or charger units.
Safe operation is no longer guaranteed:
- If the power unit shows visible damage.
- If the power unit is not working properly.
- After longer periods of storage in damp areas.
- In these cases, contact your service partner for your own safety!
Settings
The following functions are available in setting mode:
– Configuration of the serial interface
– Set up of date, time and consecutive printout numbers
– Set up of print format
– Set up of switching points
– Test functions
The setting mode is not made for metrological parameters. Access the function menu by pressing the CLEAR
(13) key until TIME appears on the display. Use the key pad (13) to navigate within the menus, to select nu-
merical values and to increase or lower the values. Press the ENTER key to save the values entered and to
return to the super ordinate menu level.

M601020-210322-Rev00 -UM-e 7
Menus structure of setting mode:
After entering the clear button following options are available and appear on the screen when moving with the
navigation buttons:
FILTER SERIAL PROGR PFORMT
SETPTS
TEST TIME DATE VERS
Setting date and time
– Enter the CLEAR key for approx. 4 sec; FILTER appears on the display.
– Press key "6" six times and TIME appears on the display.
– Press ENTER key and SHOW appears on the display.
– Press key "6" one time and HOUR appears on the display.
– Press ENTER key and set the hours using the arrow keys "2", "4", "6" and "8".
– Press the ENTER key and set the minutes and seconds.
– Go back by pressing key "2"; TIME appears on the display.
– Press key "6" one time and DATE appears on the display like the time entry.
– Press key "2" two times and EXIT Y appears on the display.
– Confirm with ENTER and date & time are set.
Operation
Modes of operation
Weighing mode
The "weighing mode" is of course the standard mode of your scale. After initial configuration and sealing (by
attaching a calibration sticker to the back of the unit), the ADE-scale can only be operated in this mode.
Setting mode
Date, time and consecutive numbers for print commands are being set in this mode. To start setting mode,
hold the GROSS/NET key pressed until TIME appears on the display.
Configuration mode (set-up mode)
The values for different parameters including the calibration could be set in the configuration mode. This func-
tion is for authorized service personnel only.
Test mode
There are different diagnostic functions for the ADE-MAK in test mode. This is for service personnel only.
Manipulations to test and configuration modes can revoke the calibration status and ill result
in loss of arranty!
Before eighing
1. Move the wheels of the bed onto the weighing platforms.
2. The constructions do not allow to pass over the weighing platform. In any case ensure that the wheels of
the bed are secured and the brakes are engaged.
3. Switch on the scale.
4. An automatic function test will lead to zero indication (0.0). The weight of the bed is being ignored auto-
matically.
5. Place the patient into the bed. The displayed weight is the weight of the patient.
6. If the weight of the patient should be ignored as well (e.g. for dialysis purposes), follow the instruction un-
der the point “Tare function”.
7. If the weight of the bed including bed-clothes is already being stored follow the instruction under the point
“Restore the preset tara value”

8 M601020-210322-Rev00 -UM-e
8. The indicator is now giving the weight of the bed.
. To evaluate the weight of the patient please follow the instructions on page 7 chapter Use of the scale
section to take patient’s eight.
10. Place each of the platforms in front of the wheels of the bed.
Weighing
Press the ON key for at least 3 seconds to turn the scales on. An automatic function test will be conducted
afterwards. The test is done when the display shows zero. The scale is now ready for the weighing procedure.
Resetting the scales back to zero: Wait until the standstill status indicator (14) appears. By entering the
ZERO key (8), measuring inaccuracies after switching on the scale are being compensated. The zero key
restarts the scale. The status indicator (6) appears when the scale is being resetted.
Tare function
The TARE key ( ) is useful for many weighing operations. Tare might be useful in case the patient is being
place on the scale/bed with items (e.g. clothing, bed clothing shoes or other items) which should be ignored by
the scale. Weigh these items first. After the weight is displayed, press the TARE key ( ) to reset the display
back to zero. The display changes to net mode (NET status indicator (5) is on) and shows zero.
Note: Taring the bed with subsequent determination of the patient weight is not possible/practical, as the bed
weight is subtracted from the maximum load of the scale and thus only a small weighing range is avail-
able. To determine the patient weight, proceed according to section "Before Weighing" on page 7.
Entering manually tare - values:
The user is able to insert manually the gross weight, which is for example mentioned at the identification plate
of the bed. Enter the appropriate tare value just by using the key pad under normal weighing mode. The value
will be stored after use of the ENTER key (or TARE). The ADE-display is now ready for weighing and changes
to net mode [NET status indicator (5) is on]. Enter the tare button to leave this mode.
Preset tara
Press and hold the PRESET TARE key (10) for approx. 3 seconds. PRO PT X appears on the display. Select
the memory location 1-10. Now enter the TARE VALUE which you would like to be ignored by the scale and
confirm same with ENTER. The value is displayed as a negative figure and will be deducted when a load is
being placed on the scale. Enter the on/off, zero – button (8) to leave this mode.
Restore the preset PRESET TARA value:
Press the PRESET TARE key (10). "Pt x" appears on the display. Enter a number from 0- (memory location
for the tare value). If no new number will be inserted to change the already displayed value within five sec-
onds, the unit will turn back to weighing mode and displays the last stored value as negative figure as above.
Enter the on/off, zero – button (8) to leave this mode.
Displaying the gross eight, net eight and tare value:
Press the "0" key to change between the net weight (gross weight minus the tared value) and the gross
weight.
Hold function
The determined weight could be continued being displayed even when the load has already been removed.
That enables taking care of the patient first before reading the results.
To use the hold function the scale must be at standstill. The standstill status indicator (14) is on and
Hold appears at the digital display. Deactivate the HOLD function by pressing the key again.

M601020-210322-Rev00 -UM-e
Determining the Body Mass Index (BMI)
The BMI figure is an index showing the ratio between height and weight.
To determine this value you need the height of the person.
Start the scale and weigh the person following the steps under weighing. Then
press the BMI key (11) to start BMI mode. The last value entered appears on the
display. Use the numerical key pad to enter a new value for the height (in cm) or retain the value, which is
already been displayed. Confirm the value entered with the ENTER key or delete same by using the CLEAR
key. After the entry has been confirmed by the ENTER key, the BMI value will be calculated using the weight
on the scales. The display changes between weight value and BMI value "b xx.x" (every two seconds) for a
period of 3 minutes. Press the BMI key (11) to cancel before this time has expired.
Evaluating Body Mass Index
Print out a record
The scales must be at standstill, e.g. standstill status display (14) appears at the screen.
Press the ENTER key (13) to send the data to the serial interface.
Note: Printing is not possible if the net weight is 0. The print function only produces one print-out. A reset is
required to print out another copy.
Care, servicing and recalibration
Cleaning
Remove the mains plug before cleaning the unit. Do not use any aggressive cleaning materials for cleaning;
only use a damp cloth or conventional disinfectant. Ensure that no liquids or any fluid gets into the scale.
Error messages
Error mes-
sage
Description Problem solution
Overload display Weight exceeds max. capacity of the
scales.
Overflow indicator (negative) Negative weight indicated – weight too
low to be displayed (<= ).
Overflow indicator (positive) Positive weight indicated – weight too
high to be displayed (>= ).
AD LOW A/D above negative range Check if the scales are correctly as-
sembled or if they are damaged.
AD HI A/D above positive range Check if the scales are correctly as-
sembled or if they are damaged.
EE SUM Parameter or calibration error Recalibrate – please contact your sup-
plier or service partner:
BMI= body weight
(height)²
BMI evaluation according to WHO
BMI
< 16 Severely underweight
16 - 17 Moderately underweight
17 - 18.5
Slightly underweight
BMI
18.5 - 25 Normal weight
BMI
25 - 30 Overweight
30 - 35 Obese Class I
35 - 40 Obese Class II
> 40 Obese Class III

10 M601020-210322-Rev00 -UM-e
EE WR EEPROM indicates an error Please contact your supplier or service
partner.
PM SUM Internal program indicates a check error Please contact your supplier or service
partner.
HOFSET Switch on – above zero Please remove the weight from the
scales and restart.
LOFSET Switch on – below zero Check scales for damage and inform
your service partner:
UOFSET Irregular
Do not touch the scales after they have
been switched on.
Waste disposal
Used electrical equipment and batteries do not belong in the domestic aste.
Please dispose of defective or used equipment and batteries according to legal regulations of
your specific country!
Please make sure that only discharged batteries or batteries ith insulated "poles" are dis-
posed of as other ise they may short-circuit!
Storage and transport conditions
Keep all packaging in case you need to return the item, in order to avoid any potential transport damage.
Disconnect all connected cables before dispatch.
Warranty
ADE will repair or replace this product within a period of 2 years from date of delivery applying to defects oc-
curred due to poor material or workmanship (presentation of invoice is necessary). All moveable parts – bat-
teries, cables, mains units, rechargeable batteries etc. – are excluded. Warranty does not include natural
wear, damages caused by incorrect or negligent handling, overuse or unsuitable or improper storage. The cost
of transport will be borne by the customer should the equipment be located anywhere other then the custom-
er’s premises. In the event of transport damage, claims under warranty can be accepted subject to using the
complete original packaging and the equipment secured the way it was packed and secured originally. All the
packaging should therefore be retained.
Any warranty claim will be rejected if the equipment is opened by persons not authorized expressively by ADE
to do so.
Customers abroad are kindly requested to contact their local dealer for any warranty claim, customer service
and spare parts.
Recalibration
Calibration to be done only by an authorised company or authorised person in accordance with national legis-
lative regulations. The CE symbol shows the authorised site (0122) and the year of initial calibration. The scale
must be recalibrated if:
- the calibration mark has been damaged
- after calibrated scales have been repaired
- or after expiry of a period for recalibration as stipulated by national, legal regulations.

M601020-210322-Rev00 -UM-e 11
Technical specifications
Po er supply
Mains Adapter:
Mains voltage 115 or 230VAC
Frequency 50 or 60HZ
Power Consumption 11W in-charger, 2W off-charger
Main power circuit
Input Voltage 5.0VDC
Max. Current (in-charger) 1000mA
Battery Requirement: Rechargeable Lithium Ion Cylindrical (18650x2) Cell 3.7V 4000mAH
Battery Operation:
Charger 7~10 Hours
Saving (350ohm, Backlight-ON 30Sec,
Shutdown 5Min) 200Hours
Serial Communications
EDP Port Full duplex RS-232
38400,1 200, 600, 4800, 2400, 1200 bps
Printer Port Output-only RS-232 or active 20 mA current loop,
600, 4800, 2400, 1200 bps
Both Ports 7 or 8 data bits; even, odd, or no parity
Operator Interface
Display 6-digit LCD display. 7-segment, 0.815 in (21.2 mm) digits
LCD annunciator net, center of zero, standstill, kg/lb/g/oz/ units,
Battery, Set points, Hold, HI/OK/LO
Keyboard 24-key flat membrane panel
Environmental
Operating Temperature –10 to +40°C (legal);
Storage Temperature –25 to +70°C
Humidity 0– 5% relative humidity
Altitude 2000 m (6500 ft) maximum
Housing
Dimensions 18.6 cm x .5 cm x 10 cm
Weight 0.4 kg (without battery)
Material ABS plastic, white

12 M601020-210322-Rev00 -UM-e
Conformity declaration
Manufacturer
:
ADE Germany GmbH
Neuer Hoeltigbaum 15
22143 Hamburg / Germany
℡ +4 40 432 776-0
+4 40 432 776-10
info@ade
-
ger
many.de
Notified body: TÜV NORD CERT GmbH
NB 0044 ( 3/42/EEC)
Langemarckstraße 20
D - 45141 Essen
℡ +4 201 825-0
+4 201 825-2517
info.tncert@tuev
-
nord.de
Declaration of conformity by the manufacturer
This product has been manufactured in accordance with the harmonised European standards. They con-
form to the regulations of the EC-directives listed below:
NAWI Directive 2014/31/EC
Medical Devices Directive 3/42/EEC
EMC Directive 2014/30/EC regarding electromagnetic compatibility
Low Voltage Directive 2014/35/EC
RoHS Directive 2011/65/EC
in the currently valid versions.
This declaration loses its validity if modifications are made to the scale without our approval.
Hamburg, March 2021
ADE Germany GmbH
Neuer Hoeltigbaum 15
22143 Hamburg / Germany

M601020-210322-Rev00 -UM-e 13

14 M601020-210322-Rev00 -UM-e

M601020-210322-Rev00 -UM-e 15

16 M601020-210322-Rev00 -UM-e
Dealer:
Table of contents
Other ADE Scale manuals