manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADE
  6. •
  7. Scale
  8. •
  9. ADE Lotta User manual

ADE Lotta User manual

This manual suits for next models

1

Other ADE Scale manuals

ADE BA 2103-1 User manual

ADE

ADE BA 2103-1 User manual

ADE BE 1613 User manual

ADE

ADE BE 1613 User manual

ADE M45610 User manual

ADE

ADE M45610 User manual

ADE BA1401 User manual

ADE

ADE BA1401 User manual

ADE M30610 User manual

ADE

ADE M30610 User manual

ADE LW100 Series User manual

ADE

ADE LW100 Series User manual

ADE KW 1703 User manual

ADE

ADE KW 1703 User manual

ADE june BA 812 User manual

ADE

ADE june BA 812 User manual

ADE KE 850 User manual

ADE

ADE KE 850 User manual

ADE KE 863 User manual

ADE

ADE KE 863 User manual

ADE KE 1421 User manual

ADE

ADE KE 1421 User manual

ADE M403020 User manual

ADE

ADE M403020 User manual

ADE GW400 Series User manual

ADE

ADE GW400 Series User manual

ADE Britta User manual

ADE

ADE Britta User manual

ADE KE 1509 User manual

ADE

ADE KE 1509 User manual

ADE Becky User manual

ADE

ADE Becky User manual

ADE KE 1203 User manual

ADE

ADE KE 1203 User manual

ADE KE 2102 User manual

ADE

ADE KE 2102 User manual

ADE KE 1129 User manual

ADE

ADE KE 1129 User manual

ADE Slim User manual

ADE

ADE Slim User manual

ADE M703600 User manual

ADE

ADE M703600 User manual

ADE Aurora BE 1711 User manual

ADE

ADE Aurora BE 1711 User manual

ADE Camille BE 1113 Solar User manual

ADE

ADE Camille BE 1113 Solar User manual

ADE BA 1300 User manual

ADE

ADE BA 1300 User manual

Popular Scale manuals by other brands

KERN MCC-M operating instructions

KERN

KERN MCC-M operating instructions

Little Balance SB MECA 8113 user manual

Little Balance

Little Balance SB MECA 8113 user manual

Fitbit Zip Aria Wi-Fi Smart Scale user manual

Fitbit Zip

Fitbit Zip Aria Wi-Fi Smart Scale user manual

KERN MPU 250K100 operating instructions

KERN

KERN MPU 250K100 operating instructions

Steinberg Systems SBS-PF-200 user manual

Steinberg Systems

Steinberg Systems SBS-PF-200 user manual

Total TP2000 user guide

Total

Total TP2000 user guide

A&D HL-200i operating instructions

A&D

A&D HL-200i operating instructions

OHAUS Courier 3000 user guide

OHAUS

OHAUS Courier 3000 user guide

Scarlett SC-KS57P97 instruction manual

Scarlett

Scarlett SC-KS57P97 instruction manual

BASETech LS-40S operating instructions

BASETech

BASETech LS-40S operating instructions

SR Instruments SR Scales SR565i-H Operating and service manual

SR Instruments

SR Instruments SR Scales SR565i-H Operating and service manual

Gallet PEP 301ART instruction manual

Gallet

Gallet PEP 301ART instruction manual

AWS ZEO-50 user manual

AWS

AWS ZEO-50 user manual

Gima Glass Body Fat Analyzer Use and maintenance book

Gima

Gima Glass Body Fat Analyzer Use and maintenance book

Seca 374 user manual

Seca

Seca 374 user manual

EDLUND BBPZ-20 quick start guide

EDLUND

EDLUND BBPZ-20 quick start guide

TEC TEC SL59 SERIES owner's manual

TEC

TEC TEC SL59 SERIES owner's manual

Alecto ACW-40 user manual

Alecto

Alecto ACW-40 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Operating Manual_N_BE1305_EN_180530_REV002
Note: The displayed value may be adversely affected under extreme electromagnetic
influences, e.g. when using a radio unit in the immediate vicinity of the device. Once the
interference has been rectified, the product can once again be used for its intended
purpose. The device may have to be switched-on again.
Statutory instructions on battery disposal
Batteries must not be disposed as household waste. The law requires that you, as
consumer, return the waste batteries either to public collection points in your town or
village or to any outlet selling batteries of the same kind.
Note:
Batteries are marked as follows:
Li = Battery contains Lithium
Al = Battery contains Alkali
Mn = Battery contains Manganese
CR (Li); AA (Al, Mn); AAA (Al, Mn)
Safety instructions for lithium batteries (CR2032/CR2430):
1. Lithium batteries are lithium manganese cells. If you do not use the scale over a longer
period, you should take out the batteries of the device.
2. Never open the lithium battery, do not put into fire, or expose to shocks because an
explosion risk lasts or discharge of poisonous exposure to fumes might possible.
3. Never touch leaked cells with bare hands.
4. When eyes or hands are contaminated, it is essential to rinse with lots of water. You
should go to a doctor if skin or eyes are irritated.
5. Dispose cells only completely discharged or protected against polarity reversal
wrapped according to your local disposal regulation.
6. Do not expose the cells to direct solar radiation and store away from heat; otherwise,
there is risk of overheating.
7. Maintain a storage temperature of < 40°C.
Disposal of old electrical and electronic equipment
1.
Model Lotta / BE 1305
Instruction Manual
Directory
1. Conditions of use....................................................... page 2
2. Commissioning............................................................page 2
3. Weighing function...................................................... page 3
4. Error Messages........................................................... page 3
5. Technical Data.............................................................page 3
6. Warranty......................................................................... page 3
1
4
This symbol on
the product or on its packaging indicates that this
product shall not be treated as household waste. Instead, it shall be
handed over to the applicable collection point for the recycling of
electrical and electronic equipment. For more detailed information
about recycling, contact your local city office, your household waste
disposal service or the shop where you purchased the product.
With kind regards
ADE (GmbH & Co.)
Thank you for your decision to purchase this high quality bathroom scale. Please peruse
read this instruction manual prior to first start up and keep this user instruction careful to
have this information on hand whenever it is needed.
2. Conditions of use
If possible, the weighing should do undressed. Please keep the weighing conditions
constant always at the same daytime. By nature, a body is subject of fluctuations (for
example loss of water after taking exercise or after a sauna visit, after a meal, etc.). To
enable comparable readings it is important to take the weighing as possible always
under the same conditions.
ADE Germany takes no responsibility for any damages or losses caused by the use of
this body analyzer scale or for Third Party claims. This product is exclusive intended for
private use. This product is not for commercial or professional use in hospitals or other
medical facilities.
2. Commissioning
Before first time use of the scale, please check at the beginning carefully if there are any
damages at the packing or at the device. Not on any account use the device if it is
damage. In this case, please immediately contact us. Our staff members willingly will help
you.
Safety guidelines: The appliance is not intend for the use of persons (including children)
with reduced physical, sensory, or mental capabilities, or lack of experience and
knowledge, unless they get supervision or instruction concerning the use of the
appliance by a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
Place the scale on a plane and firm surface (tiles, hardwood
flooring, etc.) to avoid a wrong measurement on carpeted
floor.
Always stay in the centre of the scale to prevent the scales
tipping to the side.
Attention - Hazard of slips! Do not stand on the scale with
wet feet or on a slippery surface of the weighing platform.
Please care that no heavy object may fall on the scale.
Otherwise, the glass surface could break or the scale might
become damaged.
Clean the scale only by using a slightly damp cloth. Do not
use solvents or abrasive cleaning agents. Do not submerge
the scale under water.
Preparation:
Open the battery cover at the bottom side of the scale and remove the battery safety strip.
Please ensure the correct polarity of the batteries (+/-).
There is a little switch at the bottom side of the scale for country specific settings with the
option to switch from kg = kilogram to lb = pound. Please pay attention to use the scale
under consideration of your country specific unit of weight.
3. Weighing function
1. Switch on the scale by using the step-on-function. Just step on the scale. Remain
stationary on the weighing platform and do not hold you tight. After a few seconds,
your weight will be indicated.
2. After weighing, step off the scale. The scale will switch-off automatically after a few
seconds.
4. Error Messages
“Err“ = Overload - The weight exceeds the maximum capacity of 180 kg.
Please immediately remove the critical load to avoid load cell
damage.
“Lo“ = Battery used up - Please replace the battery with the intended type
(1 x CR 2032).
5. Technical Data
Capacity x graduation: max. 180 kg x 100 g
Dimensions: 307 mm x 307 mm x 17 mm
Battery: 1 x CR 2032 (included)
Subject totechnical modifications
6. Warranty
ADE warrants for aperiod of 2 years from thedateof purchase thatit will remedy
anydefects dueto faultymaterial or workmanship freeof charge by repair or
replacement. Whenmaking a guarantee claim, please return theweighing scale
together with thesalesslip including the reason of complaint to your dealer.
CE-Conformity -This device features radio interference
suppression in compliance with valid EC Regulation 2014/30
3
2