9.Troubleshooting
Assignthat dehumidifieraputativedefect on, please, first check thefollowing points.
Ifthisshouldprovidenorelief, pleasecontactyourtechnicalconsultant.
1)Thedehumidifiershowsabadornodrying capacity
-Thehumidityislowerthan40%r.h.orthetemperatureinthatroomislowerthan
+15°C.Theusing ofthedryerisuneconomicalinthecaseof theseconditions.It is
recommendedtodisconnectthedryer. Tipp:Putthebuilt-inhygrostat(referto5.5)
onanattainablevalue(e.g.approx.50%r.F.),withitthedryerpunctuallymay
switchoff.
-Theairfilter(referto5.1–Pos.7)issoiled.Thedryerdoesnotreceiveair
sufficiently. Clean thefilterand/orinstallanewone. Asoiledairfiltercaninthe
longrunlead todisadvantagesatthedryer. Tipp: Controlthefilterregularly.
2) Thecompressorofthedehumidifierdoesnot work.
-Thedryerhasjustbeing switchedon(perhapsbecausethehumidityincreased).
Inthatcase, onlythefanstartsfirst.After3Minutesthecompressorwillalsostart.
-Thedryerisindefrost mode(referto5.8).Inthatcase,thefanworks and the
greenneon intheoperationpanel(referto5.4–Pos.3)lightsup. After10Minutes
thedryerstartscompleteworking again.
3) Thecompletedryerisoutof operation. Fanandcompressordoesnotrun.
-Istheunitsuppliedwithvoltage?Thegreenneon “operation”(referto5.4–Pos1)
mustlight up.Check themaincable, anadditionalcable,thesocket and themain
fuse.
-Thehumidityvalueadjustedat thehygrostat isachieved. Theunitwillstartagain
afterexceeding theadjustedhumidity.
-Watercollectingbucketisfull:Theredneon lightsup(referto5.4–Pos.4).
Emptythewaterbucketandputit backintotheunit.(referto5.6)
4) Strong icing up at the evaporator.
-Theambienttemperatureistolow(<+15°C).Putthedryerintoaroomwithmin.
+15°Croomtemperatureandwaituntilcompleteiceisdefrosted. Switchonthe
unit again(inthatroomwithmin.+15°C)andlet workforapprox3hours.Ifthere
isicingupagain, pleasecontactyourdealer.Otherwisemakesurethattheunit is
onlybeenusedinroomswithmorethan+15°C. Alsothestorageofthe
dehumidifieratinadmissibletemperatureconditionscan lead todamages/
problemswhileimmediateswitch-on.
5) Thehumidityadjustedatthehygrostat doesnotbecomeachieved and/orthe
devicedoesnotswitchoff automatic.:
-Isthehygrostat adjustedonavaluelowerthan 40–45%r.h.?Humidityvalues
withaminimumof40 %-45%r.h. can beachievedwithacondensationdryer.
Adjustthehygrostattoareachablevalue.
-Istheunitwithenough capacityforyourapplication? Theairchanging,numberof
thepersonsintheroomandopenwatersurfacesdecideonthehumidityburden
intheroom.Let calculatethenecessarycapacityfromyourdealer
-Istherealot ofwaterinthewallsorthefloor?Inthatcasethedryerneedssome
timetoremovethatwaterandtoachievean acceptablehumidityinthatroom.