This product must be used in accordance with the instructions in this manual and
– in particular - must not be allowed to get wet.
This product is intended to provide the user with an indication of alcohol on the
breath. However, neither the manufacturer nor the supplier gives any warranty
(express or implied) that the product can give any indication of blood alcohol level.
A person’s BAC (Blood Alcohol Concentration) can only be accurately measured by the
administration of a blood test. This product only measures breath alcohol content
which, in turn, only gives an approximately indication of blood alcohol concentration.
In these circumstances the user of this product should not rely on the
information provided thereby as an accurate indication of his blood alcohol
concentration or of his level of intoxication or of his fitness to drive and in
particular should not take any action in reliance on such information as the
product can provide no more than an indication of alcohol on the breath.
If the user of this product makes any decision or takes any action based on the
use of the product such decision or such action shall be at the sole risk of the
user and neither the manufacturer nor the supplier assumes any responsibility
for such decision or action. In particular, neither the manufacturer nor the
supplier shall be in any way liable if the user of the product asserts that the
product led him to believe that he was fit to operate a motor vehicle and is
subsequently found not to be so fit.
This product is certified pursuant to Australian Standard AS 3547 as a type 2 hand
held qualitative device.
1.
2.
3.
4.
5.
6.
The AlcoSense®Pro uses a semiconductor sensor to measure breath alcohol
levels. Depending upon the amount of alcohol registered by the sensor after a
period of time, it will require recalibration. Andatech recommends the AlcoSense®
Pro to be calibrated every 6 months or after 200 uses, whichever comes first.
For technical support please contact 1300 800 200.
a. Allow at least 20 minutes after eating or drinking before testing. Any type of
alcohol remaining in the mouth of saliva may interfere with proper testing and
requires about 20 minutes to disperse. This includes alcohol-based mouthwash or
similar products.
b. Avoid testing in high wind conditions or in poorly ventilated or enclosed spaces.
Poor ventilation may also lengthen the time required for warm up between tests.
c. Do not blow smoke, saliva or other contaminants into the mouthpiece, as the
sensor may become damaged. Wait at least 20 minutes after smoking before
conducting a test.
d. Do not use the Pro breathalyser as a tool to drink and drive.
e. Do not blow fluid into the instrument as it will damage the sensor and void your
warranty.
f. Do not store in an extreme environment where high temperature or high humidity
exists. Keep out of the reach of children.
g. To maintain accuracy, we recommend professional recalibration every 6 months.
h. Blood alcohol concentration can continue to rise for up to 2 hours after the cessation
of drinking. If a caution result or a result is close to the designated BAC, it is
recommended to wait and retest after 20 minutes.
i. It can take 10 hours or more for the alcohol level to return to a zero after a high
blood alcohol level has been reached. A further test should be carried out later in the
day of the following morning.
j. WARNING DISPLAY – FLO: If you see in the display, the breath sample was
not strong enough for measurement. Please power up the unit again and make sure
the breath is strong and steady during sampling.
k. WARNING DISPLAY – CAL or SEN: If you see or in the display, the unit
requires recalibration or maintenance. Please head to my.andatech.com.au to book
it in, or call 1300 800 200.
l. WARNING DISPLAY – BAT: If you see in the display, the unit is indicating that
battery power is low. Please replace the batteries. Remove the battery cover at the
bottom of the unit and replace the old batteries with two new 1.5V AA batteries. Make
sure to properly align the batteries by looking at the +/- marks.
m. User-serviceable batteries safety:
• Do not dispose of batteries in a fire.
• Do not recharge a battery unless it is specifically marked “rechargeable”.
• Do not expose the AlcoSense®Pro or batteries to heat source.
• Do not mix old and new batteries, or mix different types or makes of batteries.
• Do not allow children to play with the batteries.
Version 4.1. Updated 26.07.2018