manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Apollo
  6. •
  7. Security System
  8. •
  9. Apollo REACH WIRELESS RW1000-400APO User manual

Apollo REACH WIRELESS RW1000-400APO User manual

Other Apollo Security System manuals

Apollo Smoke Detector XP95 Operating and maintenance instructions

Apollo

Apollo Smoke Detector XP95 Operating and maintenance instructions

Apollo 51000-357 User manual

Apollo

Apollo 51000-357 User manual

Apollo 55000-278 User manual

Apollo

Apollo 55000-278 User manual

Apollo REACH WIRELESS RW1500-210APO User manual

Apollo

Apollo REACH WIRELESS RW1500-210APO User manual

Apollo REACH WIRELESS RW1500-210APO User manual

Apollo

Apollo REACH WIRELESS RW1500-210APO User manual

Apollo REACH WIRELESS RW1900-901APO User manual

Apollo

Apollo REACH WIRELESS RW1900-901APO User manual

Apollo 51000-305 User manual

Apollo

Apollo 51000-305 User manual

Apollo REACH WIRELESS RW1500-110APO User manual

Apollo

Apollo REACH WIRELESS RW1500-110APO User manual

Apollo 55000-278 User manual

Apollo

Apollo 55000-278 User manual

Apollo Marine & Offshore MCP2A-R470SF-A071-02 User manual

Apollo

Apollo Marine & Offshore MCP2A-R470SF-A071-02 User manual

Apollo 55100-021 MAR User manual

Apollo

Apollo 55100-021 MAR User manual

Apollo 33 404 Operating and maintenance instructions

Apollo

Apollo 33 404 Operating and maintenance instructions

Apollo XP95 IS User manual

Apollo

Apollo XP95 IS User manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

UNBOXING
• When unboxing the detector you will find the unit and its mounting base.
• This comes with pre-formed mounting holes to mountthe detector base
and a securing screw on the base to ensure there is no unwanted removal.
For more information, please refer to the user manual. Available on apollo-fire.co.uk
IMPORTANT TO CONSIDER
When mounting a wireless device, a comprehensive radio survey
should have been carried out to establish the location that provides
the best coverage and optimum reach. Taking into consideration the building
structure and materials, the survey identifies the wireless infrastructure
required and product locations for optimum performance, identifying
any factor that could prevent radio integrity.
Avoid fixing or mounting the unit close to the following:
• Equipment that utilises large electrical currents
• Large metal objects or structures
• Fluorescent lighting fittings
• Metal ceiling structures
• IT cabling.
Keep 2 meters minimum spacing between other wireless equipment
in the area to avoid signal interference.
EN54 approved environmental temperature range is -10°C to +55°C
• Remove the detector’s dust cover, intended to protect
the unit during shipping.
• Remove the detector from the base twisting
anticlockwise.
Remove the battery compartment cover on the base
on the detector.
• Aplastic pop out tag is removable from the base
to enable you to label the address of the detector,
prior to fixing to the ceiling: popout the device label tag
fromthe base and insert it into the side.
• Screw the base to the ceiling using all fixing holes
and appropriate-sized screws.
1
3
2
4
MOUNTING STEPS
Proceed as follows to complete the device installation.
5 6
Ensure the programming switch in the base of the detector
is in position ON.
Remove the batteries’ insulating tab ensuring
the batteries are kept in their lodgement.
MOUNTING
HOLES
REMOVABLE
TAG
UNLOCK
SWITCH
ON REMOVE
INSULATING
TAG
INSIDE THE BOX
• 1x Heat Detector
with mounting base
• 2 x CR123A batteries
• 1 x Quick start guide
• Locate the mounting holes and mark them using apencil
on the desired surface you are drilling.
• Using a suitable-sized drill bit (6 mm) drill the marked
screw points on your chosen surface.
• Ensure you use the correct fixings for the type of surface
you are mounting to.
RW1000-400APO
REACH Heat Detector
QUICK START GUIDE
THE BOX
Product Part Number
Product Description
RW1000-400APO
REACH Heat Detector
Apollo Fire Detectors Ltd. 36 Brookside Road, Havant, Hampshire, United Kingdom, PO9 1JR
T: +44 (0)23 9244 2706 - E: techsales@apollo-fire.com - W: www.apollo-fire.co.uk RW_QSG_DETECTOR_HEAT_REV_A.1
RW1000-400APO
Scan QR code
for full user manual
• Move the switch in the base of the detector
to position 1.
• The detector’s LED will blink few seconds green
and then signal alternatively green / red 4 times.
• Ensure you replace the battery cover as this forms
part of the detectors anti-tamper protection and refit
the detector locating it into the base twisting clockwise.
The detector’s LED will signal 4 times red.
SWITCH 1
9
78
LOCK
LED
• Secure the screw on the base to ensure there is
no unwanted removal using a M3 allen key.
10
SCREW
RW1000-400APO
REACH Heat Detector
QUICK START GUIDE
Apollo Fire Detectors Ltd. 36 Brookside Road, Havant, Hampshire, United Kingdom, PO9 1JR
T: +44 (0)23 9244 2706 - E: techsales@apollo-fire.com - W: www.apollo-fire.co.uk RW_QSG_DETECTOR_HEAT_REV_A.1