manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. B.E.G.
  6. •
  7. Security Sensor
  8. •
  9. B.E.G. LUXOMAT PD4-M-1C Series User guide

B.E.G. LUXOMAT PD4-M-1C Series User guide

1
1 2
2
120 6050
40
30
15
10
A
16 10 5
2
1
30
15
TEST
2000
1200
600
200
40
5
2000
1200
600
200
40
120 6050
40
30
15
10
A
16 10 5
2
1
30
15
TEST
2000
1200
600
200
40
5
120 6050
40
30
15
10
A
16 10 5
2
1
30
15
TEST
2000
1200
600
200
40
5
IR-PD
IR-PD-Mini
B.I.T.
Q.C.
PASSED
1
3. Putting into operation / Settings
Follow-up time for light control
The time can be set infinitely variably at between
15 seconds and 16 minutes.
Symbol : impulse < 1sec.
Symbol TEST: Test mode
(Every movement switches on the light for a period of 1
second, switching it off for a period of 2 seconds after that
regardless of the level of brightness.)
Twilight-switch for light control (relay 1)
The switch-on value for the light can be set at between 10
and 2000 Lux. Using the rotary control, the luminance set
points can be set as desired.
Symbol : Night-time operation
Symbol : Daytime/Night-time operation
Installation and Operating Instruction for B.E.G. - Occupancy detectors PD4-M-1C-FC/-FM
The detector can be installed
in conventional inlet-sockets
mounted on the ceiling.
The assembly plate enclosed
must be stripped off prior to
installation and secured to
the ceiling using 4 screws
and ensuring that it is not
laterally transposed.
Having connected up the
cables in accordance with
regulations, the detector can
be placed in position as
shown in the drawing op-
posite and, applying a little
pressure, can then be locked into position with
the assistance of the spring clips.
2b. Installation of the LUXOMAT®
PD4-M-1C-FM
Unlocking device
Lock device
4. Settings carried out using remote control (optional)
Remote control LUXOMAT IR-PD
1. Check Battery:
open battery compartment by pressing the
plastic springs together and removing the
battery-holder.
2. IMPORTANT
Please pay attention, that the setting is Potentio-
meter 1 at “TEST” and Potentiometer 2 not at
“SUN”. All values which have been programmed
using the remote control will be deleted in the
event of power failure in the position “TEST/
SUN”. Please switch Potentiometer 2 over to
“MOON” or any other value.
Caution:
Settings with remote control supersede the
settings by courtesy of potentiometers.
LUXOMAT®PD4-M-1C
1. Mounting preparations
Work on the 230 V mains supply
may only be carried out by qualified
professionals or by instructed persons
under the direction and supervision
of qualified skilled electrical person-
nel in accordance with electrotechni-
cal regulations.
Disconnect supply before installing!
When in Master/Slave mode of
operation, the Master-appliance
must always be installed at the
location where there is least
daylight.
Lock device
Test mode
Reset to deactivate
Resetting when closed
The lighting relay is switched off, i.e.
opened and the follow-up times reset.
Permanent protection against sabotage
This function blocks the unit permanently (green LED is illuminated).
This operating mode can only be activated during the period of
5 seconds after pressing the “lock“ button. This status will only
permit actuating the function “Light on/Light off”.
The procedure for leaving this mode is as follows:
1. Switch off the current
2. Apply current for 31 – 59 seconds
3. Switch of the current again
4. Apply current
5. Open detector
Light on/off
The light will remain switched on/off for as long as movements
are detected in the areas of coverage. Once the last movement
has been detected, the light will remain on for the duration of the
follow-up time as per setting.
The appliance will then return independently to the mode
selected (Fully or Semi-automatic).
2a. Installation of the LUXOMAT®
PD4-M-1C-FC
The detector has
been designed and
developed specifi-
cally for installation in
suspended ceilings.
A circular opening of
diameter 68 - 70 mm
must first of all be pro-
duced in the ceiling.
Having connected up the cables in accordance
with regulations, the detector is inserted into
the opening as shown in the drawing opposite
and fixed into position with the assistance of the
spring clip.
Option:
Wall bracket for remote
control IR-PD


max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF



 

max
50
Lux
1500
Lux
ON
OFF
Luminance set point
Automatic reading in the current light value
as new luminance set point
Individual light value 2 - 2500Lux
Follow-up time (relay and channel 1)
15 sec. up to 30min.
Impulse function (relay and channel 1)
1sec. ON, 9sec. OFF
Preset/user mode
Fully automatic/semi automatic mode => (see page 2, point 5)
Semi automatic: red LED (ashing),
Fully automatic: red LED on for ca. 3 sec.
Resetting when open
All values which have been programmed using the remote
control IR-PD are deleted, and those values which have
been set by potentiometer are activated.
120 6050
40
30
15
10
A
16 10 5
2
1
30
15
TEST
2000
1200
600
200
40
5
120 6050
40
30
15
10
A
16 10 5
2
1
30
15
TEST
2000
1200
600
200
40
5
2c. Self test cycle
The product enters an initial 60-sec-
ond self-test cycle, when the supply
is first connected. The occupancy
detector is ready for operation.
GB
1
2
max
50
Lux
1500
Lux
ON
OFF
max
50
Lux
1500
Lux
ON
OFF
24 m
8 m
6.40 m
24 m
360°
2.50 m
Sensor and power supply in one case
Power supply: 230 V~ +6 %/-10 %
Power consumption: < 1W
Ambient temperature: -25°C to +50°C
Degree of protection/class: FC and FM IP20 / II
Settings: locally and by remote control
Light values - IR-PD: 10 - 2000Lux
Extension of the detection area:
with Slaves
Area of coverage: circular 360°
Range of coverage Ø H 2.50m / T=18°C:
seated 6.40m / tangential 24 m / radial 12 m
Recommended height for mounting: 2 - 3 m
Light measurement: mixed light, daylight + artificial light
Lux values - Potentiometer: 10 - 2000 Lux
• Relay/Channel 1 for light-connection
Type of contact: NOC/with pretravel tungsten contact
Contact load: 2300 W, 230 V~, 10 A cos (ϕ) =1 /
1150 VA cos (ϕ) = 0.5
Max. no. of series-connected electronic ballasts:
max. 50 electronic ballasts by one single supply with
max. 100 m cable run and a conductur cross-section of
0.75 mm²
Time-settings: 15 sec. - 16 min. (30min. with remote
control) / test
Dimensions H x Ø [mm] FC FM
PD4-M-1C 97 x 103 84 x 106
Visible portion when built into ceiling: 34 x 103mm
Technical data PD4-Slave
Electrical data same as above, but just one channel for
signaling motion detection.
Declaration of Conformity: The product complies with
the low voltage recommendation 2006/95/EC and the
EMV recommendation 2004/108/EC
12. Technical data PD4-Master-1C
9. Wiring diagrams
Type FC FM
PD4-M-1C 92585 92575
LUXOMAT®Remote control:
IR-PD (incl. wall bracket) 92160
IR-PD-Mini 92159
Accessory:
BSK Ball basket guard 92199
Wall bracket for remote control as replacement
92100
Socket IP54 92161
11. Article / Part nr. / Accessory
MAN 6097 – 171209 – 02
In case the sensing area of the LUXOMAT®PD4-M-1C-FC
is too large or areas are being covered that should not be
monitored, the range can be reduced or limited through use
of the enclosed masking clips (e).
8. Exclude sources of interference (PD4-M-1C-FC)
5. Fully / Semi automatic mode
(for IR-PD functions see page 1)
Fully automatic operation
In this operating mode, the lighting switches automati-
cally on and off for increased comfort, depending on
presence and brightness.
Semiautomatic operation
(Semiautomatic can only be activated via the remote
control!)
In this operating condition, in order to gain increased
savings, the lighting is energized only after being manu-
ally switched on.
Switch-off takes place automatically.
The semiautomatic mode basically behaves like the fully
automatic one. However, the difference is that switching-
on must always be carried out manually!
As many (closer-contact) buttons as desired can be wired
in parallel on the “S” button input (ON/OFF).
13. LED-functional indicators, fault-finding
The functional indicators in the case of the
LUXOMAT®PD4-M-1C-MASTER (red and green LED‘s)
Red LED indicating self-checking mode (over a period
of 60 seconds following mains‘-supply lock-on)
Flashing at intervals of 1 second
EEPROM/memory empty
Flashing rapidly
EEPROM/memory contains information
Red LED as an indicator of status
Flashing irregularly
Movements are detected within the area of coverage
Flashing regularly
Detector identifies bright, light off
(dependent upon operating mode)
Not illuminated
Detector identifies dark, light on
(dependent upon operating mode)
Flashing extremely rapidly
Too bright / Too dark / Undefined
Red LED as an acknowledgement of receipt for
commands from the remote control
Illuminated for 2 seconds
Signal validly received
Illuminated for 0.5 seconds
Not-accepted command, detector blocked
Flashing extremely rapidly
Not-accepted command, occurs, for example, when an
attempt is made to input twilight-value are too bright or
too dark
Lights up for 3 seconds
Fully automatic mode
Flashing for 3 seconds
Semi automatic mode
Green LED as an indicator of status (only for status
“Permanent protection against sabotage”)
Flashing irregularly
Movement are detected within the area of coverage
Flashing regularly
Detector identifies bright, light off
(dependent upon operating mode)
Not illuminated
Detector identifies dark, light on
(dependent upon operating mode)
lluminated for 2 seconds
Signal validly received
(dependent upon operating mode)
7. Range of Coverage
6. Manual Switching
You can switch the lighting on and off manually by
pressing the pushbutton for a short time. It will stay on or
off as long as people are detected plus the congured
follow up time.
max
50
Lux
1500
Lux
ON
OFF
10. PD4-M-1C - Connections
Connection PD4-M-1C-FC/-FM
NO NO
N RL LS
SLAVE
3A
N
quer zum Melder gehen
frontal zum Melder gehen
Unterkriechschutz
walking across
walking towards
seated
Master
Standard operation
Terminal connection for standard operation
SNO NO
FC
L
N
N N L L R R
Master Slave
Master-/Slave-operation with one Master and
several Slaves.
The Master is the only unit to read in the Lux levels and to
switch the connected loads. The Slave units will react on
motion only, independently of the Lux levels, by sending an
impulse via the dry contact, to the Master.
Terminal connection for Master-/Slave-operation
S
1
2
e

This manual suits for next models

2

Other B.E.G. Security Sensor manuals

B.E.G. LUXOMAT PD2-M-DALI/DSI-1C/PD2-S User guide

B.E.G.

B.E.G. LUXOMAT PD2-M-DALI/DSI-1C/PD2-S User guide

B.E.G. LUXOMAT ALC-K-360 User guide

B.E.G.

B.E.G. LUXOMAT ALC-K-360 User guide

B.E.G. LUXOMAT PD5-M-1C-Clip User guide

B.E.G.

B.E.G. LUXOMAT PD5-M-1C-Clip User guide

B.E.G. LUXOMAT BL2 User manual

B.E.G.

B.E.G. LUXOMAT BL2 User manual

B.E.G. LUXOMAT PD2N-KNX-ST-UP User manual

B.E.G.

B.E.G. LUXOMAT PD2N-KNX-ST-UP User manual

B.E.G. LUXOMAT PD4-M-1C-GH-AP User manual

B.E.G.

B.E.G. LUXOMAT PD4-M-1C-GH-AP User manual

B.E.G. LUXOMAT PD4-M-DALI User manual

B.E.G.

B.E.G. LUXOMAT PD4-M-DALI User manual

B.E.G. LUXOMAT PD4-S Series User guide

B.E.G.

B.E.G. LUXOMAT PD4-S Series User guide

B.E.G. LUXOMAT LC-Click 140 Owner's manual

B.E.G.

B.E.G. LUXOMAT LC-Click 140 Owner's manual

B.E.G. LUXOMAT LC-Mini 120 Owner's manual

B.E.G.

B.E.G. LUXOMAT LC-Mini 120 Owner's manual

B.E.G. LUXOMAT PD9-M-2C User guide

B.E.G.

B.E.G. LUXOMAT PD9-M-2C User guide

B.E.G. LUXOMAT PD4-S-GH Firmware update

B.E.G.

B.E.G. LUXOMAT PD4-S-GH Firmware update

B.E.G. LUXOMAT Indoor 180-R User manual

B.E.G.

B.E.G. LUXOMAT Indoor 180-R User manual

B.E.G. LUXOMAT PD4-S-DAA4G User guide

B.E.G.

B.E.G. LUXOMAT PD4-S-DAA4G User guide

B.E.G. Luxomat PD2-DIM Series User manual

B.E.G.

B.E.G. Luxomat PD2-DIM Series User manual

B.E.G. LUXOMAT PD9-M-DIM User guide

B.E.G.

B.E.G. LUXOMAT PD9-M-DIM User guide

B.E.G. WAVE-PIR-120-DR-(O/V) User manual

B.E.G.

B.E.G. WAVE-PIR-120-DR-(O/V) User manual

B.E.G. LUXOMAT BL2 User manual

B.E.G.

B.E.G. LUXOMAT BL2 User manual

B.E.G. LUXOMAT net PD2N-KNX-DX User manual

B.E.G.

B.E.G. LUXOMAT net PD2N-KNX-DX User manual

B.E.G. LUXOMAT PD9-M-DALI/DSI-FC User guide

B.E.G.

B.E.G. LUXOMAT PD9-M-DALI/DSI-FC User guide

B.E.G. LUXOMAT PD4-M-DIM-Corridor Series User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-DIM-Corridor Series User guide

B.E.G. LUXOMAT PICO-N-M-1C-FC User guide

B.E.G.

B.E.G. LUXOMAT PICO-N-M-1C-FC User guide

B.E.G. LUXOMAT LC-Click 140 Owner's manual

B.E.G.

B.E.G. LUXOMAT LC-Click 140 Owner's manual

B.E.G. LUXOMAT PD4-M-DALI/DSI-C User guide

B.E.G.

B.E.G. LUXOMAT PD4-M-DALI/DSI-C User guide

Popular Security Sensor manuals by other brands

teko Astra-MA user guide

teko

teko Astra-MA user guide

Texecom Prestige DT installation instructions

Texecom

Texecom Prestige DT installation instructions

C-LOGIC 645-MD instruction manual

C-LOGIC

C-LOGIC 645-MD instruction manual

Minelab VANQUISH 340 Getting started

Minelab

Minelab VANQUISH 340 Getting started

ASO Safety Solutions GE F-series manual

ASO Safety Solutions

ASO Safety Solutions GE F-series manual

PCB Piezotronics 117B31 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 117B31 Installation and operating manual

Extech Instruments DV690 user manual

Extech Instruments

Extech Instruments DV690 user manual

nest Detect user guide

nest

nest Detect user guide

Siemens S7-1500F manual

Siemens

Siemens S7-1500F manual

Waters 2487 Dual A Operator's guide

Waters

Waters 2487 Dual A Operator's guide

ADEMCO 11BR Installation instruction

ADEMCO

ADEMCO 11BR Installation instruction

Inter-m AFD-614 Service manual

Inter-m

Inter-m AFD-614 Service manual

PCB Piezotronics 4105-01A Installation and operating manual

PCB Piezotronics

PCB Piezotronics 4105-01A Installation and operating manual

AccuLine 40-6715 instruction manual

AccuLine

AccuLine 40-6715 instruction manual

Apogee Instruments SE-100 owner's manual

Apogee Instruments

Apogee Instruments SE-100 owner's manual

Optex AX-330PLUS installation instructions

Optex

Optex AX-330PLUS installation instructions

FIREGUARD GLOBAL FG-BD100 Product introduction

FIREGUARD GLOBAL

FIREGUARD GLOBAL FG-BD100 Product introduction

Lince ZENITH GOLD 869 Series Installation and operating manual

Lince

Lince ZENITH GOLD 869 Series Installation and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.