TROUBLESHOOTING
The door will not
open.
The LED is OFF.
The sensor power is off. Check the wiring and the power supply.
The complete declaration of conformity is available by contacting BEA
The door will not
close.
The LED is OFF.
The door opens
and closes
constantly.
The blue LED is on.
The sensor detects
objects outside its
detection field.
The blue LED is on.
The blue LED
flashes quickly
after unlocking.
The sensor does
not respond to the
remote control.
Improper output
configuration on the sensor.
The sensor is disturbed
by the door motion or
vibrations caused by the
door motion.
The sensor needs an access
code to unlock.
Batteries in the remote
control are weak or
installed improperly.
It rains and the
sensor detects for
no apparent reason.
The blue LED is on.
The sensor detects the
motion of the rain drops.
Remote control incorrectly
oriented.
Check the output configuration setting on each
sensor connected to the door operator.
Verify door control is operational.
Make sure the sensor is mounted properly.
Make sure the detection mode is unidirectional.
Increase the tilt angle.
Reduce the field size.
Increase the immunity filter.
Increase the immunity filter.
Decrease the field size.
Enter an access code.
Cut and restore the power supply to access the
sensor. Change or delete the access code.
Check and change the batteries if necessary.
Point the remote control towards the sensor.
Make sure the detection mode is unidirectional.
Increase the immunity filter.
Install the ERC (rain accessory).
Metallic environment
ACCESS CODE
The access code (1 to 4 digits) is recommended to program sensors installed close to each other.
If you forget the access code, cycle the power supply.
Within the first minute, you can access the sensor without introducing any access code.
SAVING OR CHANGING AN ACCESS CODE:
DELETING AN ACCESS CODE:
SPARROW
2
1
3
4
5
75.5730.01 20120914 SPARROW Page 1 of 4
Speci
the manufacturer.
TECHNICAL SPECIFICATIONS
DESCRIPTION
ENGLISH
Motion activation sensor
for automatic industrial doors*
1. cover
2. main connector
3. radar antenna
4. DIP-switch
5. push buttons
6. LEDs
Technology:
Transmitter frequency:
Transmitter radiated power:
Transmitter power density:
Detection mode:
Min. detection speed:
Supply voltage:
Mains frequency:
Max power consumption:
Output:
Max. contact voltage:
Max. contact current:
Max. switching power:
Mounting height:
Degree of protection:
Temperature range:
Dimensions:
Tilt angles:
Material:
Weight:
Cable length:
Norm conformity:
microwave
24.150 GHz
< 20 dBm EIRP
< 5 mW/cm²
motion
2 in/s (measured in the sensor axis)
12V to 24V AC ±10%; 12V to 24V DC +30% / -10%
50 to 60 Hz
< 2 W
relay (free of potential change-over contact)
42V AC - 60V DC
1A (resistive)
30W (DC) / 60VA (AC)
6.5 ft to 20 ft
IP64
-22 °F to + 140 °F
5.51 in (L) x 2.17 in (H) x 2.25 in (W)
0° to 90° vertical; -120° to +120° lateral
ABS
5.8 oz
30 ft
R&TTE 1999/5/EC; EMC 2004/108/EC