1 | Overview
3.2 | Attach the inputs
3 | Connecting the wires to the keypad
CAUTION!
Remove all power (AC and battery) before making any
connections. Failure to do so might result in personal injury
and/or equipment damage.
5 | Status indicators
Status
indicator
Function
Ready to turn on (arm)
Turned on (armed)
System trouble
GAS Gas alarm
AC power present
1. To show the start up screen, apply power to the keypad or push
Time/Date for 5 seconds. You can also push anywhere on Call for
Service screen.
2. Hold the countdown icon for 5 seconds to show the addressing page.
3. Use the up and down arrows to change the ones and tens digits.
4. Push (Escape) to save the setting and return to the power up
screen.
Attach the wires to the keypad and to any inputs or outputs before you
install the keypad.
3.1 | Attach to the control panel
Use the control panel terminals labeled R, Y, G, B (PWR, A, B, COM).
Connect them to the keypad terminals labeled R, Y, G, B.
You can connect keypads to the SDI2 data bus by parallel wire run from
the control panel to each keypad, wire from keypad to keypad, or a
combination of the two techniques. Refer to the following illustrations
in this section.
Callout ― Description
1 ― Control panel
2 ― Terminal wiring
3 ― Keypad’s wiring terminal block
1 COM 2 3 COMCOM AUX R Y G B
PWR A B COM
3 COM 41 COM 2
R Y G B
AUX
- 12 V +
1 k End of Line Resistors
3.7 - 5.0 VDC
2.0 - 3.0 VDC
0.0 - 13 VDC
Open
Normal
Short
5 COM 6
R Y G B
1
3
2
R Y G B
PWR A B COM 1 COM 2 COM 3 COM 4 COM NO C
R Y G B
PWR A B COM 1 COM 2 COM 3 COM 4 COM NO C
R Y G B
PWR A B COM 1 COM 2 COM 3 COM 4COM NO C
R Y G B
PWR A B COM 1 COM 2 COM 3 COM 4COM NO C
Wire resistance on each sensor input must be less than
100 Ω with the detection devices connected. The terminal block
supports 18 to 22 AWG (1.02 to 0.65 mm) wires.
The keypad identifies open, short, normal, and ground fault circuit
conditions on its sensor loops and transmits the conditions to the
control panel. Each sensor loop has a point number and transmits to
the control panel individually.
Run wires away from any telephone
and AC wiring.
R Y G B
PWR A B COM 1 COM 2 COM 3 COM 4 COM NO C
Callout ― Description
1 ― Keypad terminal strip
2 ― Keypad sensor loops
3 ― 1 kΩ EOL resistor (ICP-1K22AWG-10)
3.3 | Attach the output
The keypad provides one NO (normally open) output. It includes NO
and C (COMMON) terminals. When the output is active (energized),
the NO has continuity with the C terminal.
1. Align the mounting hook opennings over the hooks.
2. Push the keypad down.
NOTICE!
Do not exceed relay contact ratings of 1.0 A, 24 VDC,
resistive load.
3.4 | Install the keypad
1. Put the keypad on a smooth surface.
2. Use a ballpoint pen to press the button on the terminal release.
3. Put the wire into the terminal. When you remove the pen, the
terminal release locks the wire.
4. To remove wires, press the terminal release.
5. Gently pull the wire out.
NOTICE!
Use the strip gauge on the plate to reduce wires to 7 mm.
Attach one wire per terminal.
1 COM 2 3 COMCOM AUX R Y G B
PWR A B COM
3 COM 41 COM 2
R Y G B
AUX
- 12 V +
1 k End of Line Resistors
3.7 - 5.0 VDC
2.0 - 3.0 VDC
0.0 - 13 VDC
Open
Normal
Short
5 COM 6
R Y G B
R Y G B
PWR A B COM 1 COM 2 COM 3 COM 4 COM NO C
R Y G B
PWR A B COM 1 COM 2 COM 3 COM 4 COM NO C
R
Y
G
B
R Y G B
PWR A B COM 1 COM 2 COM 3 COM 4 COM NO C
R Y G B
PWR A B COM 1 COM 2 COM 3 COM 4 COM NO C
4 | Set the address
Each SDI2 keypad must have a unique address. For single-digit
addresses 1 through 9, set the tens switch to 0. The following
illustration shows the address switch setting for address 1.
NOTICE!
Only use your finger or a touch screen stylus on the
keypad.
NOTICE!
To prevent damage to the terminals, use a ballpoint pen. Do
not use a screwdriver.
2 | Installation
1. Insert a slotted screwdriver under the retention clip to release
the clip. Do not twist upwards.
2. Move the plate towards the bottom of the keypad. Refer to the
following illustration.
1. Use the flush mounting plate (Left side in the following
illuistration) or the surface mounting plate (Right side in the
following illustration).
2. Use the plate as a template to mark the wall for installation.
3. Make sure it is level.
4. Pull the wiring through the wiring openning.
STRIP GAUGE
2.1 | Remove the mounting plate
2.2 | Install the mounting plate
This keypad is SDI2 compatible with four inputs and one output.
1
3
2
Callout ― Description
1 ― Power indicator LED
2 ― Integrated proximity reader (for use with RF ID tokens and
access cards)
3 ― Presence sensor
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Alemanha
© 2018 Bosch Security Systems, Inc. F.01U.294.527 | 08 | 2018.05
Copyright
This document is the intellectual property of Bosch Security Systems,
Inc. and is protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are
likely to be registered trademarks and must be treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the
Bosch Security Systems, Inc. website at
http://www.boschsecurity.com/datecodes/.
El-gr: Μεταβείτε στη διεύθυνση https://gr.boschsecurity.com/el/ για την
τεκμηρίωση σε αυτήν τη γλώσσα.
Es-es: Visite https://es.boschsecurity.com/es/ para obtener documentación en
este idioma.
Fr-fr: Accédez à l’adresse https://fr.boschsecurity.com/fr/ pour obtenir la
documentation dans cette langue.
Hu-hu: A honosított dokumentációt lásd a https://hu.boschsecurity.com/hu/
oldalon.
It-it: Andare a https://it.boschsecurity.com/it/ per la documentazione in questa
lingua.
Pl-pl: Dokumentacja w tym języku znajduje się w witrynie https://
pl.boschsecurity.com/pl/
Pt-br: Acesse http://pt.boschsecurity.com/pt/ para obter a documentação neste
idioma.
12 | Certifications
Region Certification
US UL 1076 - Proprietary Burglar Alarm Units and Systems
UL 1610 - Central Station Burglar Alarm Units
CSFM - California Office of The State Fire Marshal
FCC Part 15 Class B
ANSI/SIA CP-01-2010 - Control Panel Standard - Features
for False Alarm Reduction
CA Canada CAN/ULC S303 - Local Burglar Alarm Units and
Systems
CAN/ULC S304 - Signal Receiving Centre and Premise
Alarm Control Units
CAN/ULC S545 - Residential Fire Warning System Control
Units
ULC-ORD C1023 - Household Burglar Alarm System Units
ULC-ORD C1076 - Proprietary Burglar Alarm Units and
Systems
ICES-003 - Digital Apparatus
14 | Specifications
Dimensions 6.2 in x 4.7 in x 0.6 in
(158 mm x 120 mm x 16 mm)
Voltage (input) 12 VDC nominal
Current with prox
detection disabled
200 mA in standby mode
300 mA in alarm mode
Current with prox
detection enabled
300 mA in standby mode
400 mA in alarm mode
Operating temperature 0°C to +50°C (+32°F to +122°F)
12 | Keypad cleaning
Use a soft cloth or a non-abrasive cleaning solution. Spray the cleaner
onto the cloth, not the keypad.
Relative humidity 5% to 93% at +32°C (+90°F) non-
condensing
Terminal wire size 18 AWG to 22 AWG (1.02 mm to 0.65
mm)
SDI2 wiring with prox
detector disabled
Maximum distance - wire size
(unshielded wire only):
200 ft (61 m) - 22 AWG (0.65 mm)
520 ft (159 m) - 18 AWG (1.02 mm)
SDI2 wiring with prox
detector enabled
Maximum distance - wire size (unshielded
wire only):
150 ft (46 m) - 22 AWG (0.65 mm)
390 ft (119 m) - 18 AWG (1.02 mm)
Compatibility B9512G/B9512G-E
B8512G/B8512G-E
B6512
B5512/B5512E firmware v2.03 and higher
B4512/B4512E firmware v2.03 and higher
B3512/B3512E firmware v2.03 and higher
D9412GV4 firmware v2.03 and higher
D7412GV4 firmware v2.03 and higher
(Refer to the control panel installation
document for number of supported
devices.)
The control panel supervises all SDI2 devices. Any device
that fails to respond will be declared missing.
7 | Supervision
11 | Firmware updates
8 | Proximity reader
1. Go to us.boschsecurity.com.
2. Download the firmware from the B942 product page.
3. Save the firmware to your MicroSD card.
4. Make sure the keypad is powered.
5. Move the MicroSD card into the slot until it clicks into place.
6. Wait while the keypad shows Please wait while programming flash.
7. If the keypad shows the calibration screen, follow the on-screen
instructions.
8. Remove the SD card when the keypad shows Firmware update
successful. Remove SD card to continue.
9. Push down quickly on the card.
10. Use your fingernail on the upper groove on the card to push it
out.
11. The keypad shows the power up screen with the updated
revision number and then shows the Home screen.
Firmware updates require a MicroSD card (
2 GB to 32 GB).
R Y G B
PWR A B COM 1 COM 2 COM 3 COM 4 COM NO C
10 | Addresses, points, and output numbers
To determine the point numbers or output number for each keypad
address, multiply the address number by 10 for the base number, and
then use numbers 1 through 4 in the ones place for the point
numbers. Use 1 in the ones place for the output number.
Examples
For keypad address 01 the point numbers for the input devices are 11
through 14:
Terminal number 1 2 3 4
Input number 11 12 13 14
For output devices connected to the NO and C terminals the output
number is 11.
For keypad address 11 the point numbers for the input devices are 111
through 114:
Terminal number 1 2 3 4
Point number 111 112 113 114
For output devices connected to the NO and C terminals the output
number is 111.
9 | Configure programmable keys functions
Use RPS to set the A,B,C Key Response parameters (KEYPADS/Global
Keypad Settings) as follows:
- Fire key: set A Key Response to Manual fire alarm.
- Medical key: set B Key Response to Manual medical alarm (with or
without alarm bell).
- Panic key: set C Key Response to Manual panic alarm (invisible or
visible).
13 | Certifications
6 | Audible tones
The keypad has a built-in speaker that produces distinct warning tones.
Tone Description
Fire alarm Emits a pulsed, high-pitched bell tone.
Gas alarm Emits a unique high pitched tone.
User alarm The tone sounds for the programmed amount
of time.
Burglary alarm Emits a steady, high pitched bell tone.
Entry delay Emits an intermittent beep tone during entry
delay periods.
Exit delay Emits an intermittent beep tone during exit
delay.
Invalid button
buzz
Emits a flat buzz tone.
Keypress Emits a muted beep tone.
Trouble Emits a two-tone warble until you enter a pro-
grammed passcode.
Watch point fault Emits a single clean tweedle tone.
The proximity reader allows users to use a token or card in place
of a passcode to turn on or off the security system. The proximity
reader supports EM4102 (125 kHz) credentials. The Bosch ACA-
ATR13-RFID tag and Bosch ACD-ATR11ISO-RFID card are examples.
en Installation Guide
Touch Screen Keypad
B942/B942W

Other manuals for B942

3

This manual suits for next models

1

Other Bosch Keypad manuals

Bosch ARD-AYCF64 User manual

Bosch

Bosch ARD-AYCF64 User manual

Bosch D626 User manual

Bosch

Bosch D626 User manual

Bosch FMR-7036 User manual

Bosch

Bosch FMR-7036 User manual

Bosch RF3341 User manual

Bosch

Bosch RF3341 User manual

Bosch AMAX 2100 User manual

Bosch

Bosch AMAX 2100 User manual

Bosch D9412G User manual

Bosch

Bosch D9412G User manual

Bosch D223TD User manual

Bosch

Bosch D223TD User manual

Bosch B942 User manual

Bosch

Bosch B942 User manual

Bosch FMR-DACT-KEYPAD User manual

Bosch

Bosch FMR-DACT-KEYPAD User manual

Bosch AVENAR 8000 User manual

Bosch

Bosch AVENAR 8000 User manual

Bosch DS7447V2 Series User manual

Bosch

Bosch DS7447V2 Series User manual

Bosch D1260 Series User manual

Bosch

Bosch D1260 Series User manual

Bosch B920 User manual

Bosch

Bosch B920 User manual

Bosch D1260 Series User manual

Bosch

Bosch D1260 Series User manual

Bosch D621 Series User manual

Bosch

Bosch D621 Series User manual

Bosch TouchOne User manual

Bosch

Bosch TouchOne User manual

Bosch B925F User manual

Bosch

Bosch B925F User manual

Bosch DS7446KP User manual

Bosch

Bosch DS7446KP User manual

Bosch SmartKey User manual

Bosch

Bosch SmartKey User manual

Bosch D621 Series User manual

Bosch

Bosch D621 Series User manual

Bosch CP799B How to use

Bosch

Bosch CP799B How to use

Bosch SOLUTION 6000 Instruction manual

Bosch

Bosch SOLUTION 6000 Instruction manual

Bosch ICP-CP4TS User manual

Bosch

Bosch ICP-CP4TS User manual

Bosch D202A Series User manual

Bosch

Bosch D202A Series User manual

Popular Keypad manuals by other brands

ACT ACT 10 DIGITAL KEYPAD Operating and installation instructions

ACT

ACT ACT 10 DIGITAL KEYPAD Operating and installation instructions

Visonic MKP-150 user guide

Visonic

Visonic MKP-150 user guide

Honeywell ADEMCO 5828 Installation and setup guide

Honeywell

Honeywell ADEMCO 5828 Installation and setup guide

Crestron ZUM  ZUMMESH-KP installation guide

Crestron

Crestron ZUM ZUMMESH-KP installation guide

Videx VX8902F instruction manual

Videx

Videx VX8902F instruction manual

Storm Interface Audio-Nav 1400 Series Technical manual

Storm Interface

Storm Interface Audio-Nav 1400 Series Technical manual

Smanos KP-20 user manual

Smanos

Smanos KP-20 user manual

ADEMCO 6137 installation guide

ADEMCO

ADEMCO 6137 installation guide

Select Engineered Systems SPRFC1 user manual

Select Engineered Systems

Select Engineered Systems SPRFC1 user manual

Sargent and Greenleaf 6120-420 manual

Sargent and Greenleaf

Sargent and Greenleaf 6120-420 manual

Assa Abloy S series Installation & programming guide

Assa Abloy

Assa Abloy S series Installation & programming guide

Aidcall Touchsafe Pro user guide

Aidcall

Aidcall Touchsafe Pro user guide

Satel INT-SCR manual

Satel

Satel INT-SCR manual

ANXELL E-Access E3AK Series instructions

ANXELL

ANXELL E-Access E3AK Series instructions

Digital Monitoring Products Thinline 7070 Installation sheet

Digital Monitoring Products

Digital Monitoring Products Thinline 7070 Installation sheet

ZETRON 025-9636A installation instructions

ZETRON

ZETRON 025-9636A installation instructions

Satel INT-SCR-BL manual

Satel

Satel INT-SCR-BL manual

Russound Sphere E Series installation manual

Russound

Russound Sphere E Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.