manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Bosch
  6. •
  7. Security Sensor
  8. •
  9. Bosch ISC-CDL1-W15G User manual

Bosch ISC-CDL1-W15G User manual

=
3 | Bracket mount (optional)
Changes or modifications not expressly approved
by Bosch Security Systems, Inc. can void the
user’s authority to operate the equipment.
UL/C-UL
Use only a Listed Class 2 limited-power source.
Standby power: The Listed control unit or a Listed
burglary power supply must provide 4 hours of
standby power.
Install the unit in accordance with National
Electrical Code NFPA 70 and Part 1 of the
Canadian Electrical code CSA C22.1.
Models ISC-CDL1-W15H & ISC-CDL1-W15K are
not UL or C-UL Listed.
1
2
B328
B338
B335
FCC
This device complies with part 15 of the FCC
Rules. and Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following
two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference,
including interference that may cause undesired
operation of the device.
Le présent appareil est conforme aux CNR
d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée
aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le
fonctionnement.
Under Industry Canada regulations, this radio
transmitter may only operate using an antenna of
a type and maximum (or lesser) gain approved for
the transmitter by Industry Canada.
To reduce potential radio interference to other
users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated
power (e.i.r.p.) is not more than that necessary
for successful communication.
Conformément à la réglementation d’Industrie
Canada, le présent émetteur radio peut
fonctionner avec une antenne d’un type et
d’un gain maximal (ou inférieur) approuvé pour
l’émetteur par Industrie Canada.
Dans le but de réduire les risques de brouillage
radioélectrique à l’intention des autres
utilisateurs, il faut choisir le type d’antenne et
son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas
l’intensité nécessaire à l’établissement d’une
communication satisfaisante.
This product is intended for use in the
following countries within the European Union
and in other countries outside the European
Union:
ISC-CDL1-W15G (10.525 GHz): Austria,
Belgium, Denmark, Finland, Greece, Italy,
Luxembourg, Netherlands, Norway, Portugal,
Spain, Sweden.
ISC-CDL1-W15H (10.588 GHz): France, United
Kingdom
ISC-CDL1-W15K (9.35 GHz): Germany
2 | Surface mount
1 | Unlock and open
2,3m - 2,75 m
(7.5 ft - 9 ft)
Test yearly
Optional Brackets: B328, B338, B335
A mounting bracket can reduce the detector’s
range and create dead zones. Not investigated
by UL. Not EN50131 compliant. La certificazione
IMQ decade nel caso di installazione del
rilevatore con gli snodi opzionali.
Bosch Security Systems, Inc. F.01U.304.624 | 03 | 2015.01 | 2
7b | Double EOL resistors
7a | Single EOL resistor
7 | Wiring
6 | Leveling5 | Wire knock-out options
12
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
NC NC
T
T
NC NC T
T
12
9 to 15 VDC
TT
2
NC NC T
T
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
NCNC
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
NC NC T
T
TT
2
1
NC
NC
4 | Terminal block removal
1
2
Bosch Security Systems, Inc. F.01U.304.624 | 03 | 2015.01 | 3
7c | No EOL resistors
HI
LO
LED
PIR
1 2
ON
EN Grade 2
1 2
ON
9 | Look-down feature
8 | DIP switches
10b | Microwave adjustment
10a | Walk test
2 min
2 s 2 s
1
3
2
1
2
10c | Repeat walk test
2 min
2 s 2 s
1
3
2
NC NC T
T
1
2
2.2 k
1.0 k
2.2 k
33 k
1.0 k
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
en Installation Guide
Commercial Series
TriTech detectors
ISC-CDL1-W15G,
ISC-CDL1-W15H, ISC-CDL1-W15K
© 2015 Bosch Security Systems, Inc. F.01U.304.624 | 03 | 2015.01
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
Voltage
(operating)
9 to 15 VDC, 9-15 V
9-15 Vcc
de 10 à 15 mA @ 12
Vcc en veille/en alarme,
source limitée en
puissance, ondulation
résiduelle 1 V.
Current
(maximum)
<35 mA
Alarm relay /
Tamper
<100 mA, 25 V , 2.5W
Operating
temperature
-30°C to +55°C
(-22°F to +130°F)
UL 0°C to +49°C
(+32°F to +120°F)
AFNOR/CNPP
-10°C to +55°C
Relative
humidity
95% non-condensing
UL and C-UL 93%
Copyright
This document is the intellectual property of Bosch Security Systems, Inc. and is
protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be
registered trademarks and must be treated accordingly.
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the Bosch Security
Systems, Inc. website at http://www.boschsecurity.com/datecodes/.
0 m 2 m 4 m 6 m 8 m 10 m
15 m
0 ft 7 ft 13 ft 20 ft 26 ft 33 ft
50 ft
0 m
7.5 m
6 m
4 m
2 m
0 m
2 m
4 m
6 m
7.5 m
0 ft
25 ft
20 ft
13 ft
7 ft
0 ft
7 ft
13 ft
20 ft
25 ft
≥2.3 m ≥7.5 ft
≤2.75 m ≤9 ft
12 m
39 ft
14 m
46 ft
90°
Region Agency Certification
US FCC FCC Part 15 Class B
UL -W15G: Intrusion Detection Unit Type: S
Canada CUL -W15G: Intrusion Detection Unit Type: S
IC 1249A-CDL1
Europe CENELEC EN 50131-2-4
EN 50130-5
Environmental Class II,
Grade 2 / IP41 / IK04 (EN60529, EN 62262)
France AFNOR/
CNPP
NF&A2P (ISC-CDL1-W15H seulement)
ISC-CDL1-WA15H Cert # xxxxxxxxxxxx
RTC 50131-2-4
NF-324-H58 2 boucliers – 110P2
AFNOR Certification: www.afnor.org
CNPP Cert.: www.cnpp.com
Autosurveillance à l’ouverture Immunité champ
magnétique
Germany VdS VdS Gxxxxxx
Class B
2110EN Enviromental Class 2
Belgium ANPI/
INCERT
INCERT B-509-00xx/a: (ISC-CDL1-W15G)
Australia ACMA RCM
Italy IMQ Certificato IMQ sistemi di sicurezza 3° livello di
prestazione secondo CEI79-2:1998 + Ab:2000
(modello W15G)
Sweden SBSC For svensk installationsanvisning se
www.boschsecurity.se
11 | Certifications 12 | Specifications
13 | Coverage pattern

Other manuals for ISC-CDL1-W15G

1

This manual suits for next models

2

Other Bosch Security Sensor manuals

Bosch ISC-BDL2-WP6 User manual

Bosch

Bosch ISC-BDL2-WP6 User manual

Bosch IR LD 1.0 User manual

Bosch

Bosch IR LD 1.0 User manual

Bosch DS936 User manual

Bosch

Bosch DS936 User manual

Bosch DS915 User manual

Bosch

Bosch DS915 User manual

Bosch DS820 User manual

Bosch

Bosch DS820 User manual

Bosch UniversalDetect User manual

Bosch

Bosch UniversalDetect User manual

Bosch UniversalDetect User manual

Bosch

Bosch UniversalDetect User manual

Bosch DM-TP-50(80) User manual

Bosch

Bosch DM-TP-50(80) User manual

Bosch ISC-BDL2-WP12 User manual

Bosch

Bosch ISC-BDL2-WP12 User manual

Bosch ISC-PPR1-WA16G User manual

Bosch

Bosch ISC-PPR1-WA16G User manual

Bosch Motion Detector User manual

Bosch

Bosch Motion Detector User manual

Bosch Blue Line Q1 User manual

Bosch

Bosch Blue Line Q1 User manual

Bosch GMS 120 Professional User manual

Bosch

Bosch GMS 120 Professional User manual

Bosch AVIOTEC IPSTARLIGHT 8000 Technical manual

Bosch

Bosch AVIOTEC IPSTARLIGHT 8000 Technical manual

Bosch MX938I User manual

Bosch

Bosch MX938I User manual

Bosch D603 User manual

Bosch

Bosch D603 User manual

Bosch DS306E User manual

Bosch

Bosch DS306E User manual

Bosch DS1109i Operating instructions

Bosch

Bosch DS1109i Operating instructions

Bosch DS432i-CHI User manual

Bosch

Bosch DS432i-CHI User manual

Bosch FCA-350-B4 User manual

Bosch

Bosch FCA-350-B4 User manual

Bosch CS LD 1.0 User manual

Bosch

Bosch CS LD 1.0 User manual

Bosch RF835E User manual

Bosch

Bosch RF835E User manual

Bosch LTC 2210 Series User manual

Bosch

Bosch LTC 2210 Series User manual

Bosch PAVIRO Series User manual

Bosch

Bosch PAVIRO Series User manual

Popular Security Sensor manuals by other brands

Chamberlain 771E-02 quick start guide

Chamberlain

Chamberlain 771E-02 quick start guide

Abtech BOSUNS manual

Abtech

Abtech BOSUNS manual

HME COMMUNICATOR COM6000 instructions

HME

HME COMMUNICATOR COM6000 instructions

netvox Z801TXB user manual

netvox

netvox Z801TXB user manual

WatchfulEye WTH-CS/RS485 Series user manual

WatchfulEye

WatchfulEye WTH-CS/RS485 Series user manual

SKYLOTEC CS 10 / 2 Instructions for use

SKYLOTEC

SKYLOTEC CS 10 / 2 Instructions for use

AVE AF962 quick start guide

AVE

AVE AF962 quick start guide

ROBLAN CASAMBI 227CBUCOPD17MOLF installation manual

ROBLAN

ROBLAN CASAMBI 227CBUCOPD17MOLF installation manual

Elsema MD240-2 manual

Elsema

Elsema MD240-2 manual

Analytical Technology PortaSens III D16 instruction manual

Analytical Technology

Analytical Technology PortaSens III D16 instruction manual

Chemtronics 22 manual

Chemtronics

Chemtronics 22 manual

Honeywell NFPA 1971 User's information guide

Honeywell

Honeywell NFPA 1971 User's information guide

DSC Force2 installation instructions

DSC

DSC Force2 installation instructions

Recco R9 quick guide

Recco

Recco R9 quick guide

SKYLOTEC LORY Series Instructions for use

SKYLOTEC

SKYLOTEC LORY Series Instructions for use

DINUY DP KNX 001 quick start guide

DINUY

DINUY DP KNX 001 quick start guide

Di-soric DCC 12 VHD 2 PS-B3-56-7 quick start guide

Di-soric

Di-soric DCC 12 VHD 2 PS-B3-56-7 quick start guide

Ferport NoTouch 2 Operating and installation instructions

Ferport

Ferport NoTouch 2 Operating and installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.