manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BWI Eagle
  6. •
  7. Transmitter
  8. •
  9. BWI Eagle AIR-EAGLE SR PLUS Manual

BWI Eagle AIR-EAGLE SR PLUS Manual

Other manuals for AIR-EAGLE SR PLUS

17

This manual suits for next models

1

Other BWI Eagle Transmitter manuals

BWI Eagle AIR-EAGLE XLT 441AN/D-1000-120VAC Manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT 441AN/D-1000-120VAC Manual

BWI Eagle AIR-EAGLE SR PLUS User manual

BWI Eagle

BWI Eagle AIR-EAGLE SR PLUS User manual

BWI Eagle AIR-EAGLE FM2 43-1000-120VAC Manual

BWI Eagle

BWI Eagle AIR-EAGLE FM2 43-1000-120VAC Manual

BWI Eagle AIR-EAGLE XLT User manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT User manual

BWI Eagle AIR-EAGLE FM2 43-1000N4W-120VAC Manual

BWI Eagle

BWI Eagle AIR-EAGLE FM2 43-1000N4W-120VAC Manual

BWI Eagle AIR-EAGLE SR PLUS 36-HH-1 User manual

BWI Eagle

BWI Eagle AIR-EAGLE SR PLUS 36-HH-1 User manual

BWI Eagle AIR-EAGLE XLT PLUS 461-1800-DC User manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT PLUS 461-1800-DC User manual

BWI Eagle AIR-EAGLE XLT Manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT Manual

BWI Eagle AIR-EAGLE FM2 43-1100R2-DC Manual

BWI Eagle

BWI Eagle AIR-EAGLE FM2 43-1100R2-DC Manual

BWI Eagle AIR-EAGLE XLT 44-10100-120I-AC Manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT 44-10100-120I-AC Manual

BWI Eagle AIR-EAGLE SR PLUS 36-1400-4B-120VAC Manual

BWI Eagle

BWI Eagle AIR-EAGLE SR PLUS 36-1400-4B-120VAC Manual

BWI Eagle AIR-EAGLE XLT PLUS User manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT PLUS User manual

BWI Eagle AIR-EAGLE FM2 43-1000-BAT Manual

BWI Eagle

BWI Eagle AIR-EAGLE FM2 43-1000-BAT Manual

BWI Eagle AIR-EAGLE XLT 441-HH-9-VBR Manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT 441-HH-9-VBR Manual

BWI Eagle AIR-EAGLE XLT Manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT Manual

BWI Eagle AIR-EAGLE XLT PLUS 497-5100-CHx-DC Manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT PLUS 497-5100-CHx-DC Manual

BWI Eagle AIR-EAGLE SR PLUS 36-10100-120I-AC Manual

BWI Eagle

BWI Eagle AIR-EAGLE SR PLUS 36-10100-120I-AC Manual

BWI Eagle AIR-EAGLE SR PLUS User manual

BWI Eagle

BWI Eagle AIR-EAGLE SR PLUS User manual

BWI Eagle AIR-EAGLE SR PLUS User manual

BWI Eagle

BWI Eagle AIR-EAGLE SR PLUS User manual

BWI Eagle AIR-EAGLE XLT Manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT Manual

BWI Eagle AIR-EAGLE XLT Manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT Manual

BWI Eagle AIR-EAGLE SR PLUS 36-1400-4B-DC Manual

BWI Eagle

BWI Eagle AIR-EAGLE SR PLUS 36-1400-4B-DC Manual

BWI Eagle AIR-EAGLE XLT Manual

BWI Eagle

BWI Eagle AIR-EAGLE XLT Manual

BWI Eagle AIR-EAGLE FM2 43-1000-RB-N4-120VAC Manual

BWI Eagle

BWI Eagle AIR-EAGLE FM2 43-1000-RB-N4-120VAC Manual

Popular Transmitter manuals by other brands

Seneca K120RTD installation manual

Seneca

Seneca K120RTD installation manual

Nautel GV40 installation manual

Nautel

Nautel GV40 installation manual

HumanTechnik cm-light operating instructions

HumanTechnik

HumanTechnik cm-light operating instructions

INOR APAQ C130 TC User instructions

INOR

INOR APAQ C130 TC User instructions

Linear DXS-64 operating instructions

Linear

Linear DXS-64 operating instructions

FeinTech ABT00102 instruction manual

FeinTech

FeinTech ABT00102 instruction manual

Geo Web Pack quick start guide

Geo

Geo Web Pack quick start guide

Inovonics EchoStream EN1210W installation instructions

Inovonics

Inovonics EchoStream EN1210W installation instructions

IKONNIK KA-6 quick start guide

IKONNIK

IKONNIK KA-6 quick start guide

Rohde & Schwarz SR8000 Series System manual

Rohde & Schwarz

Rohde & Schwarz SR8000 Series System manual

Audio Technica UniPak ATW-T93 Installation and operation

Audio Technica

Audio Technica UniPak ATW-T93 Installation and operation

NIVELCO EasyTREK SCA-300 Series Programming manual

NIVELCO

NIVELCO EasyTREK SCA-300 Series Programming manual

Honeywell 5816WMBR installation instructions

Honeywell

Honeywell 5816WMBR installation instructions

Kamstrup READy MTU Installation and operation guide

Kamstrup

Kamstrup READy MTU Installation and operation guide

Omega ZW Series user guide

Omega

Omega ZW Series user guide

ABB Field 264H Instructions for installation

ABB

ABB Field 264H Instructions for installation

Dejero EnGo 3x manual

Dejero

Dejero EnGo 3x manual

Rosemount 4600 Reference manual

Rosemount

Rosemount 4600 Reference manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PRODUCT INFORMATION
BULLETIN
105 Bonnie Drive
Butler, PA 16002
724-283-4681
724-283-5939 (fax)
www.bwieagle.com
AIR-EAGLE®SR PLUS
2.4 GHz RF Transmitter
MODEL 36-1400-AC
DESCRIPTION
The AIR-EAGLE SRPLUS TX is an R.F. transmitter capable of sending
four independent dry contact input commands to an Air-Eagle SR
Receiver from up to 600 feet away. Any number of transmitters and
receivers can be combined to create a medium-range remote control
system that operates hazardous or hard-to-reach electrical apparatus
from safe, convenient locations. This unit has eight user-selectable
network frequencies to allow multiple systems to operate
simultaneously in the same area without interference.
APPROVALS
United States (FCC)
MCQ-XBEE3
Canada (IC)
1846A-XBEE3
Europe (CE)
ETSI
INSTALLATION
1. Mount the AIR-EAGLE SR PLUS TRANSMITTER in a convenient
location.
2. Install wiring to contact input terminal strip (Note –the terminal block
header lifts off the base for easy wiring)
3. Attach supplied antenna to connector on right side of unit.
4. Connectsupplied power input cable to your external power source.
TERMINAL STRIP WIRING
Wire as shown based on number of contact inputs
1
2
3
4
5
6
7
8
9
10
C Input 1
Input 1
C Input 2
Input 2
C Input 3
Input 3
C Input 4
Input 4
100-250 VAC (N)
Power Input
100-250 VAC (H)
Power Input
GENERAL OPERATION
A closure on any input transmits its channelcommand to activate the
corresponding relay in the remote receiver. The transmission continues as
long as the input is closed and ceases when the input opens.
Dimensions (with mounting plate) 6.3” L x 4.8” W x 2.3” H
CONTROLS & INDICATORS
TX LED
Illuminates green when power is applied.
Changes to red while any contact input is
closed and unit is transmitting.
Dry Contact Inputs
Transmits individual RF codes to the receiver
SEL1
Dip switch bank for frequency selection
SEL2
Dip switch bank for digital address selection
AIR-EAGLE®SR PLUS
2.4 GHz RF Transmitter
MODEL 36-1400-AC
FREQUENCY & DIGITAL ADDRESS SET-UP
This transmitter is factory programmed to Frequency “1”and Digital
Address “1”. These settings can be changed by the user in any
combination but must match the receiver that is set up to
communicate with this transmitter. Note –only change digital
address if using with a digitally addressable receiver. Otherwise, the
digital address must be kept at the default of Digital Address “1”.
1) Remove power from unit.
2) Remove top cover.
3) Select desired network frequency and/or digital address using table
below.
4) Reattach cover and apply power.
5) Programming is now complete.
FREQUENCY SET-UP
SEL1 (SW1-3)
SEL1
(SW1-3)
Network
Frequency
SW1
SW2
SW3
1 (default)
OPEN
OPEN
OPEN
2
CLOSED
OPEN
OPEN
3
OPEN
CLOSED
OPEN
4
CLOSED
CLOSED
OPEN
5
OPEN
OPEN
CLOSED
6
CLOSED
OPEN
CLOSED
7
OPEN
CLOSED
CLOSED
8
CLOSED
CLOSED
CLOSED
SEL1 (SW4) –Not used on this model
DIGITAL ADDRESS SET-UP
SEL2 (SW1 –4)
SEL2
(SW1-4)
Digital
Address
SW1
SW2
SW3
SW4
1 (default)
OPEN
OPEN
OPEN
OPEN
2
CLOSED
OPEN
OPEN
OPEN
3
OPEN
CLOSED
OPEN
OPEN
4
CLOSED
CLOSED
OPEN
OPEN
5
OPEN
OPEN
CLOSED
OPEN
6
CLOSED
OPEN
CLOSED
OPEN
7
OPEN
CLOSED
CLOSED
OPEN
8
CLOSED
CLOSED
CLOSED
OPEN
9
OPEN
OPEN
OPEN
CLOSED
10
CLOSED
OPEN
OPEN
CLOSED
11
OPEN
CLOSED
OPEN
CLOSED
12
CLOSED
CLOSED
OPEN
CLOSED
13
OPEN
OPEN
CLOSED
CLOSED
14
CLOSED
OPEN
CLOSED
CLOSED
15
OPEN
CLOSED
CLOSED
CLOSED
16
CLOSED
CLOSED
CLOSED
CLOSED
SEL2 (SW5-7) –Leave in OPEN position!!
SPECIFICATIONS
Power Input
100-250 VAC, 5 W, 50/60 Hz
Transmit Frequency
2.4GHz Spread Spectrum
Transmitter Inputs
Dry Contact
RF Networks
Eight Independent Frequencies
Digital Addresses
Sixteen
RF Networks
Eight Independent Frequencies
RF Output Power
60 mW
Transmit Range
Up to 600 Feet
Note: Max range figures are estimates, based on free-air terrain with limited sources of
interference. Actual range will vary based on transmitting power, orientation of
transmitter and receiver, height of transmitting antenna, height of receiving antenna,
weather conditions, interference sources in the area, and terrain between receiver and
transmitter, including, but not limited to, indoor and outdoor structures such as walls,
metal objects, trees, buildings, hills, and mountains
Antenna Connection
TNC Female
Enclosure
Polycarbonate, IP66 (NEMA 4)
Operating Temperature
-40oF to +185oF
ACCESSORIES
Standard Antenna (Included):
2.4GHz TNC “Rubber Duck” Antenna
49-1201
Mobile/Base Antennas –
Used to help achieve max range in both nonline of sight andline of
sight applications. - Contact BWI Eagle for recommendations
2.4GHz Thru-Hole Mount Mobile Antenna
49-2201
2.4GHz Magnet Mount Mobile Antenna
49-2202
2.4GHz Omni Directional Base Antenna
49-3201
2.4GHz Yagi Directional Base Antenna
49-3202
High Quality Coax Cables –
Used to connect external high gain antennas to control unit
Flex Coax Cable w/Connectors –Available in
5’,15’,25’,30’,40’,60’,80’,100’ Lengths
49-4000-XX
(XX = # of
Feet)
Bulkhead Extensions –
Used to provide an external antenna connection whenmounting
control unit inside another enclosure
TNC Male to TNCBulkhead CableAssembly -
Available in 2’, 4’, 7’ Lengths
49-5004-X-ISO
(X = # of Feet)
DOCUMENT DATE: 07/21/2021 / PRODUCT REV. 6
WARRANTY STATEMENT
BWI Eagle Inc. warrants the Air-Eagle Remote Control System, if properly used and installed, will be free
from defects in material and workmanship for a period of 1 year after date of purchase. Said warranty to
include the repair or replacement of defective equipment. This warranty does not cover damage due to
external causes, including accident, problems with electrical power, usage not in accordance with product
instructions, misuse, neglect, alteration, repair, improper installation, or improper testing. This limited
warranty, and any implied warranties that may exist under state law, apply only to the original purchaser of
the equipment, and last only for as long as such purchaser continues to own the equipment. This warranty
replaces all other warranties, express or implied including, but not limited to, the implied warranties or
merchantability and fitness for a particular purpose. BWI Eagle makes no express warranties beyond
those stated here. BWI disclaims without limitation, implied warranties of merchantability and fitness for a
particular purpose. Some jurisdictions do not allow the exclusion of implied warranties so this limitation
may not apply to you. To obtain warranty service, contact BWI Eagle for a return material authorization.
When returning equipment to BWI Eagle, the customer assumes the risk of damage or loss during
shipping and is responsible for the shipping costs incurred.
SIGNAL RANGE
Max range statements are estimates based on a clear line of sight with few interferences. Actual range will
vary based on transmitting power, orientation of transmitter and receiver, height of transmitting and
receiving antennas, weather conditions, electronic interference, terrain, and physical obstacles, including
but not limited to; walls, building structures, trees (foliage), metal objects, and landscape (hills, mountains).
WIRELESS STOP, ASTOP, and E-STOP SYSTEMS
Wireless E-STOP systems should never be considered a primary life-saving device. At
least one hard-wired switch must be available in the event the wireless system is not
operational. Failure to comply may result in serious injury or death to personnel and
damage to equipment.
Wireless STOP and ASTOP transmitters are not failsafe emergency stop controls.
They are NOT to be used as a life-saving device. They are designed for wireless
control of equipment or vehicle remote operation. Failure to use as intended may result
in serious injury or death to personnel and damage to equipment.