Two people are recommended for the installation ofthisfountain!
-WINTERCARE-
Fountainbowls/topsandotherfountaincomponents,whichcollect water, shouldnotbeleftoutsideinthewinter since anycomponent,
whichfillswithwater andfreezesmaycrack.Likewise, componentssuchaspedestals,whichremaininabasin,filledwithwater,
whichthenfreezes,mayalsocrackor crumble. Ideally, therefore, afountainshouldalwaysbestoredindoorsor inadryprotected
place suchasacoveredporchawayfromtheelements. However, ifafountainmustbeleftoutside:
(1) Removepump, rubber stoppers, drainpipes, finials,andother smallcomponentsfor storageindoors. Note that stoppersor
drainpipesareremovedtoallowdrainageintheeventwater accumulatesinanybasin.
(2) Raisefountainbasefromgroundwithwood stripssothat basewill notfreeze tothegroundsurface.
(3) Cover or wrapthefountainwithburlapor other absorbentmaterial (oldblanket or towel) andthencover securelywith
plastic,making surethat water will notaccumulate inthebasinor other fountaincomponentandfreeze;
(4) Checkfountainperiodicallytoinsurethat plastic issecureandwater isnotaccumulating inanyfountaincomponent.
-GENERALFOUNTAINTIPS-
Install fountainsonalevel surface. Youwill needaproperlygrounded110-volt (AConly) GFCI protectedreceptaclenear the
fountainfor your pump. All pumpsaresubmersible andmustbecompletelyunderwater tofunctionproperly. Testall pumpsand
adjusttofull outputprior toassembly. Itisnotrecommendedthat fountainsbeplaceddirectlyongrass or dirt. Positionthechannel
opening at thebaseofeachfountaintoward theelectrical outlet tobeusedsince thepump
cord willbethreadedthroughthisopening.
CheckoutYouTubefor a“Howto”video.
For moreCampania product informationvisit www.campaniainternational.com
All of ourcaststone is proudly
Pump KitPartsList
PK300 pump (1)
#10 stopper(1)
Approx. 12” lengthof ½” BlackNon-kinktubing(1)
¾” male threaded ½” barbadapter (plastic adapter) (1)
21” lengthof 1”copperpipe(1)
Wedges(4)
Hose clamps(3)
*Hoseclamps maybe used asflow restrictors
FOUNTAININFORMATION:
Thisfountain holdsapproximately33 gallonsof water.
Thisfountain usesamediumfountain cover.
(FTNCOV-MED)
Compatible with#10 Refill Device and LEDKits
(Aspecialstopper isrequiredtousethe refill kit for
thisfountain.)
TOOLSREQUIRED:
Bubble Level
PUMPINFORMATION:
PF320 –320GPH Pump
16 FTcord length