Canon CXDI-60G User manual

C
C
X
X
D
D
I
I
-
-
6
6
0
0G
G
/
/
6
6
0
0
C
C
C
Ca
an
no
on
n
I
In
nc
c.
.
J
Ja
ap
pa
an
n
C
Co
op
py
yr
ri
ig
gh
ht
t
(
(C
C)
)
C
Ca
an
no
on
n
I
In
nc
c.
.
M
Me
ed
di
ic
ca
al
l
T
Te
ec
ch
hn
ni
ic
ca
al
l
S
Se
er
rv
vi
ic
ce
e
D
De
ep
pt
t.
.
A
Al
ll
l
r
ri
ig
gh
ht
ts
s
R
Re
es
se
er
rv
ve
ed
d.
.
S
Se
er
rv
vi
ic
ce
e
M
Ma
an
nu
ua
al
l
P
Pr
ri
in
nt
te
ed
d
b
by
y
C
Ca
an
no
on
n
I
In
nc
c.
.
J
Ju
ul
l.
.
2
20
00
09
9
R
Re
ev
v.
.0
01
1
Confidential

Manual Control No. : BY8-2300-0E0
Name of Product : CXDI-60G/60C
Distribution Control No.
Issued on
Service Manual Introduction
This service manual belongs to a series of after-service guides Canon Inc. publishes as part of
its comprehensive product quality guarantee program.
This service manual consists of nine chapters; “General”, “Installation Manual”, “Functions”,
“Repair Guide”, “Parts Catalog”, “Troubleshooting”, “Service Manual Report”, “Tools” and
“Appendix”. It describes an overview of the product, its functions, product configuration,
installation procedures, dimensions, specifications, and notes.
If the product undergoes a large modification, a revised edition of the service manual will be
sent to you. In other cases, a service manual report will be sent to you to update the manual.
Note 1:
This service manual is published by Canon Inc. in accordance with Article 6 (Furnishing
the Referring Materials) of the Service Assignment Contract it has concluded with your
company.
Note 2:
This service manual is the property of Canon Inc. and the company may seek to have it
returned, depending on the circumstances. You are expected to keep it until then.
Note 3:
You inquiries, suggestions, etc. about the contents of this service manual should be
addressed to:
Medical Equipment Technical Service Dept.
Canon Inc. Headquarters
30-2, Shimomaruko 3-chome, Ohta-ku, Tokyo 146-8501, Japan

Caution Regarding Service
This product was precisely assembled under strict manufacturing process control. There
are several hazardous locations inside of this product. Careless work while the cover is
removed can result in the pinching of fingers or electrical shock. Please perform the work
with the following important points in mind:
1. Setup, Repair, and Maintenance
In order to ensure safety, the best performance, setup, repair, and maintenance work can only
be performed by technicians who have received service training specified by Canon Inc. If
there are order required certificates or restrictions specified by the law or ordinances, those
regulations of the country must be observed.
2. Removing the external cover
When removing the cover during maintenance, repair, etc., perform the work after switching
the power off. Never touch the device with wet hands, as there is a risk of electric shock.
3. Fuse
When replacing the fuse, first resolve the reason for its failure and then replace the fuse with
the specified type. Never use a fuse other than the specified type.
4. Connecting the grounding wire
The provided ground wire must be connected to the ground terminal indoors. Make sure that
the device is properly grounded.
5. Alternation prohibition
Never modify the medical device in any way.
6. Waste control
The service provider is responsible for the disposal of used service parts, packing material,
etc. resulting from the setup, repair, or maintenance of the medical device. However, the
customer is responsible for the disposal of the medical device. Disposal activities must
follow the regulations (especially controlled industrial waste) of the country where the
device is used.

VORSICHT
Befolgen Sie die unten angegebenen Sicherheitsanweisungen.
Mißachtung kann zu erletzungenoder Unfällen führen.
1.Zerlegung, Zusammenbau, Einstellung und Wartung
Zerlegung, Zusammenbau, Einstellung und Wartung dürfen nur von einem Wartungstechniker
durchgeführt werden, der an einem von Canon vorgeschriebenen Wartungslehrgang teilgenommen hat.
2.Entfernen von Abdeckungen
Schalten Sie unbedingt die Stromversorgung des Instruments aus, bevor Sie die Abdeckungen zwecks
Wartung und Reparatur entfernen.
Vermeiden Sie auch eine Berührung des Instruments mit nassen Händen.
Anderenfalls können Sie einen elektrischen Schlag erleiden, der zum Tod oder schwerer Verletzung
führen kann.
3.Sicherung
Wenn die Sicherung ausgewechselt werden muß, schalten Sie unbedingt die Stromversorgung des
Instruments aus, und beheben Sie die Ursache für das Durchbrennen der Sicherung.
Ersetzen Sie die Sicherung nur durch den vorgeschriebenen Typ.
Anderenfalls kann es zu einem Brand oder elektrischen Schlag kommen.
4.Erdleiter
Erden Sie das Instrument unbedingt an einer Schukosteckdose.
Anderenfalls kann es zu einem Brand oder elektrischen Schlag durch Leckstrom kommen.
5.Umbau
Jeder Umbau des Produktes ist strengstens untersagt, da dies zu einem Brand oder elektrischen Schlag
führen kann.

C
Ca
au
ut
ti
io
on
n
R
Re
eg
ga
ar
rd
di
in
ng
g
t
th
he
e
S
Se
et
tu
up
p
According to “IEC60601-1-1:2000”, devices installed in the patient environment are restricted
to “electric medical devices conforming to IEC60601-1”.
The Control PC and operation unit are classified under the data processing device standard
(IEC60950), therefore these items should not be installed in the patient environment.
The patient environment described below is an example cited from “IEC60601-1-1:2000” – the
measurements are only guidelines. However, the “IEC60601-1-1:2000” example must be treated
as the standard.
Therefore, the Control PC and operation unit must be installed in a location further than the
measurements below (outside of the patient environment).
*Areas where the patient moves (not only during imaging but when entering and leaving
the room, etc.) are also considered as part of the patient environment, therefore the
installation location should be determined upon consultation with the user regarding
areas outside of the patient environment.
Example of patient environment
Note: These measurements are only guidelines.

C
CX
XD
DI
I-
-6
60
0G
G/
/6
60
0C
C
C
Ca
an
no
on
n
I
In
nc
c.
.
J
Ja
ap
pa
an
n
C
Co
op
py
yr
ri
ig
gh
ht
t
(
(C
C)
)
C
Ca
an
no
on
n
I
In
nc
c.
.
M
Me
ed
di
ic
ca
al
l
T
Te
ec
ch
hn
ni
ic
ca
al
l
S
Se
er
rv
vi
ic
ce
e
D
De
ep
pt
t.
.
A
Al
ll
l
r
ri
ig
gh
ht
ts
s
R
Re
es
se
er
rv
ve
ed
d.
.
1
1.
.G
Ge
en
ne
e
r
r
a
al
l
Printed by Canon Inc.
Jul. 2009 Rev.01

Contents
1 General .................................................................................................................................. 1
2 CXDI System Block Diagram ............................................................................................... 2
3 System Diagram .................................................................................................................... 3
4 CXDI Image Processing ........................................................................................................ 4
5 Specifications......................................................................................................................... 5

1. General
1
1 General
CXDI-60G/60C represents a compact cassette model that enhances user convenience in cassette-
based digital radiography. It is used in combination with Control computer (CXDI-C3, CXDI-C3S,
FC-24VE, FC-E21A or the general computers with equal performance).
The sensor cable is organized into two parts. The one is a sensor cable S150-60 (imaging unit side)
and the other is a sensor cable P630 (power box side). Two cables are connected with the connectors.
It adopts the detachable connector, which is compatible with the CXDI-55G/55C, allowing the use
of two sizes portable flat panel detector.
The vertical scanning drive (Drv-IC) and the data read out (Amp-IC) are located in one side of
LANMIT. Image data is read out from one direction.
The appearance of the CXDI-60G is almost the same as that of the CXDI-60C, but their fluorescence
substances that convert X-ray into visible light are different.
CXDI-60G
CXDI Software Ver.7.0 and later
Serial number of CXDI-60G imaging unit 100001 and later
Serial number of CXDI-60G imaging unit (non-
logo model)
300001 and later
CXDI-60C
CXDI Software Ver.7.2 and later
Serial number of CXDI-60C imaging unit 100001 and later
Notes on usage
From the view of risk management, guarantee is not made for the waterproofing for blood and
chemicals, hygienic safety in operating room, usage with a defibrillation device in ICU, outdoor
usage or application to animals. If the imaging unit needs to be used under such condition, the
system integrator should be responsible for the operation and understanding of the tolerance of the
product specification.

1. General
2
2 CXDI System Block Diagram
Symbol Description Remarks
CA1 AC Cable 3m
CA2 Sensor Cable 6.3m
CA3 X-Ray I/F Cable 20m
CA4 LAN Cable (Category 5)
CA5 LAN Cable (Category 5)
CA6 Serial Cable (Touch Panel)
CA7 VGA Cable
CA8 AC Cable 3m
Operation
Unit
RS232C
VGA
Network
Ethernet
(100/10base-T)
AC100V~240V±10% 50/60Hz 2.2A
Mouse
Power Box
OUT PUT 1
Control/Signal/
Power
OUT PUT 2
Control/Signal
AC Power IN
AC100/120V/230V
CA1
CA6
CA7
CA8
Imaging Unit
(CXDI-60G/60C)
Control/Signal
/Power
Control
computer
VGA
LAN1
AC Power IN
MOUSE
KEY BOARD Key Board
Printer
Image file device
Image diagnosis
W/S
X-Ray
I/F
CA2
LAN2
CA3
CA4
CA5
Remote Switch
X-Ray Generator
SERIA1(COM1)
SERIAL(COM2)

1. General
3
3 System Diagram
3.1 Standalone System
Standalone System Block Diagram
AC or DC IN
Protective
Grounding
1st / 2nd
AC250V
Insulation with
reinforcement
Power Supply
AC250V
Basic Insulation
Imaging Unit
Grid Unit
Remote Switch
X-ray Generator
(601Compatible)
FC-24VE/FC-E21A
or
Recommended general computer
Patient Circumstances or Medical Room
Power Box
SELV*
Control/Signal
Control
Control/Signal
Control/Signal
Ethernet
* SELV = Safety Extra-Low Voltage
CXDI-60G/60C
General HUB
(1)
(2)
Connector
3.2 Total System
It can be connect to (1) and (2) of the system where the existing products have already been
connected. Extend the ethernet port by general switching HUB or ethernet card. The maximum
number of connections is limited to four by the control software specification.
Total System Block Diagram (Example)
AC or DC IN
Protective
Grounding
1st/2nd
AC250V
Insulation
with reinforcement
Power Supply
AC250V
Basic Insulation
Imaging Unit
Grid Unit
Remote Switch
X-ray generator
(601 Compatible)
FC-24VE/FC-E21A
or
Recommended general computer
Patient Circumstances or Medical Room
Power Box
SELV*
Control/Signal
Control
Control/Signal
Control/Signal
Ethernet
*SELV = Safety Extra-Low Voltagej
CXDI-60G/60C
General HUB
Power Box
CXDI-40E
Imaging Unit
Control/Signal
Ethernet
Power Box CXDI-50
Imaging Unit
Control/Signal
Ethernet
Ethernet
Image Examination WS
Image File Equipment
Printer etc.
Connector

1. General
4
4 CXDI Image Processing
4.1 Proccess Flow
4.2 Image Types
(1) BORN IMAGE
The image obtained with LANMIT before any correction is made.
Outside distribution of these images is prohibited, including dtstore images.
(2) RAW IMAGE
Born image after offset processing, gain correction.
This is the image with LANMIT specific characteristics corrected.
(3) ORIGINAL IMAGE
Raw image after preprocessing.
(4) QA IMAGE
Original image after gradation processing, sharpening, and other processing.
The CXDI performs image processing up to this point.
(5) DIAGNOSIS IMAGE
QA image after further image processing necessary for diagnosis.
Image processed by the user for diagnostic purposes.
(6) PROCESSED IMAGE
Diagnosis image after post-processing.
Image modified by the user or the default processed image.
Born image
Raw image
Original image
QA image
Diagnosis image
Processed image
Correction
processing
QA processing
Offset correction
Gain correction
Defect correction
dtstore
Characteristic extraction
•Sensitivity correction
•Sharpening
•DEP
•Gradation processing
•MTF enhancement
(Frequency enhancement)
•Grid stripe reduction
•High density clipping
request
DICOM output

1. General
5
5 Specifications
The CXDI-60G/60C (Imaging Unit/Power Box) is the Digital Cassette that has the mobility and
can be used on the optional angles.
(1) Imaging Unit
This unit consists of the internal sensor, PWB-60Di, PCB-AD/REF, PWB-60LED and its
outer cover. The sensor unit converts the X-ray image to the electrical signal (O/E
Conversion) and after performing the A/D conversion, transfers its signal through the Power
Box with Ethernet cable to the Control computer.
Item CXDI-31 CXDI-60G/60C Remarks
Object Cassette (built-in) Cassette (built-in)/Mobile
Effective filming
range 226.00 x 288.00 mm 234.24 x 284.16 mm
Number of Pixels 2260 x 2280
(About 6,500,000 pixel)
1476 x 1790
(About 2,600,000 pixel)
Effective
Number of Pixels 2256 x 2878 1464 x 1776
Pixel pitch 100µm x 100µm 160µm x 160µm
Fluorescent
substance GOS 60G:GOS/60C:CsI
Output
gradations
12bit (4,096 gradations)
A/D 14bit
Transfer method
Metal: Imaging Unit to E/O BOX
Optical fiber: E/O BOX to
Control computer (Through the
Multi Box)
Ethernet: Imaging Unit to Control
computer (Through the Power Box)
Imaging time ~ 1 sec.
Imaging cycle 15 sec.
Dimension 324(W) x 327(D) x 20.8(H) mm 344.4 (W) x 380* (D) x 22.5 (H) mm
Imaging Unit
coloring Art gray Cool white
Imaging Unit
mass
(w/o grid)
2.8Kg
(Except the cable)
3.3Kg
(Including the cable)
2.5Kg
(Except the cable)
2.8Kg
(including the cable)
Space between
surface where
patient gets in
contact (CFRP)
and sensor
surface (glass)
5.75mm Within 5.1±0.5mm.
Average (43.2kJ/h) Remote SW OFF 36kJ/h or less
Heat emission Max 162kJ/h Max load mode 126kJ/h or less
1 image per 15 Sec.
Average (12W) Remote SW OFF 10W or less
Power
Consumption Max 45W Max load mode
35W or less
(1 image per 15
Sec.)
Mechanical
strength*
Load uniformly: 1.47kN(150kgf), 1min
Load locally: 0.98kN(100kgf),
φ
40mm, 1min
The imaging unit is put on the plain surface with the Sensor side (Detector) is
up.
Self-imposed rule
For CXDI-31, local
strength applies to
the center of the
sensor.
Control
computer
-CXDI-C2
-CXDI-C3
-FC-24VE/FC-E21A for CXDI Control
Station
-General computer with a performance
equal to FC-24VE/FC-E21A
-CXDI-C3/C3S
Ethernet card is
necessary to connect
CXDI-60G/60C with
CXDI-C3
Power Control
(ON/OFF) Interface with a Control computer
None
(Power Box: Operation with Remote
switch manually)
Grid
attach/remove
detector
Yes

1. General
6
Item CXDI-31 CXDI-60G/60C Remarks
Sensor cable From imaging unit to E/O Box:
4.5m
Sensor cable (imaging unit side): 1.5m
Sensor cable (power box side): 6.3m
Count of
connected sensor
Up to four imaging units are
connectable to a single control
computer via multi box. For the same
type of imaging unit, the maximum of
connection number will be three.
Up to four Imaging Units are connectable to a
single control computer via Network switch.
For the same type of imaging unit, the
maximum of connection number will be three.
Each imaging unit requires a power box.
Network switch
should be procured
at each sales
company.
Scattered
radiation
backward block
sheet
Environment-
conscious
unleaded type
Lead cover Mo sheet (0.3 mm thick)
Photo timer Cannot be built in
Imaging
restriction
(Imaging
Prohibition)
When the internal temperature of
Imaging Unit is above 45 degree
Celsius, its state is changed to sleep
mode. And the Imaging prohibition
will be continued when the internal
temperature is below 44 degree
Celsius.
When the internal temperature of Imaging Unit
is above 49 degree Celsius, its state is changed
to sleep mode. And the Imaging prohibition
will be continued when the internal
temperature is below 48 degree Celsius.
User interface Indication Indication Busy Sensor Power
Color Two colors Color Orange
*1
Green Blue
Imaging
unit is off Off Imaging
unit is off Off Off Off
Imaging
unit is on
Orange light will turn
on
Imaging
unit is on -- Off On
Preparing
imaging Green light will flash*1 Preparing
imaging -- Blinking
*2 On
Imaging
preparation
complete
Green light will turn on
Imaging
preparation
complete
-- On On
Error status Green light will flash*2 Error status -- Blinking
*3 On
Communi-
cating On -- On
Initialization
(when
startup)
-- Blinking
*4 On
Network not
set (when
startup)
-- Blinking
*5 On
*1: Turns on and off for 0.5 seconds
each
*2: Turns on and off twice for 0.5
seconds, then turns off for 0.5
seconds
*1: Green for China
*2: Turns on and off for 0.5 seconds each
*3: Turns on and off twice for 0.5 seconds,
then turns off for 0.5 seconds
*4: Fades in for 1 second and fades out for 1
second
*5: Fades in for 2 seconds, and then turns off

1. General
7
(2) Power Box
This unit consists of PWB-60X-RAY, 60 Sensor Power Supply and its outer cover.
The function; the signal transition between Imaging unit and Control computer, the interface
to the X-ray generator equipment and power supply to the Imaging unit has been
implemented.
Item Content Remarks
Communication method
with Control computer IEEEE*802.3u (100BASE-TX) * Connector type: RJ45
Communication method
with PWB-60XRAY
Asynchronous serial communication
method
Data length: 10bit
Data rate: 15.625 kHz
Power supply AC 100-240V 50/60Hz 1.2-0.7A
Reference
60 Sensor Power supply
Rated Voltage:
AC 100-240V (AC 85-264V)
Mass 3.7 Kg Except the external cables
Dimension 358(W) x 200(D) x 65(H)* mm
Except bottom rubber parts
(With bottom rubber parts:
75mm)
(3) Environment rated parameters
Item Content Remarks
Ambient temperature +5 to +35°C
Relative humidity 30 to 75% RH
Operating
environment Atmospheric pressure 700 to 1060 hPa
Must be without dewing
Ambient temperature -30 to 50°C
Relative humidity 10 to 60% RH
Storing or
transporting
environment Atmospheric pressure 700 to 1060hPa
Must be without dewing
*IEEE: Institute of Electrical and Electronic Engineers

C
CX
XD
DI
I-
-6
60
0G
G/
/6
60
0C
C
Canon Inc. Japan
Copyright(C) Canon Inc. Medical Technical Service Dept. All rights reserved.
2
2.
.
I
In
ns
st
ta
al
ll
la
at
ti
io
on
n
M
M
a
an
nu
ua
al
l
Printed by Canon
Jul. 2009 Rev. 01

Contents
1 Caution During the Installation ............................................................................................ 1
2 Restrictions on Installation ................................................................................................... 1
3 Caution on Installation ......................................................................................................... 2
4 Product Configuration .......................................................................................................... 3
4.1 Product Configuration List........................................................................................... 3
4.2 Configuration ............................................................................................................... 4
4.3 Sensor Cable (Optional) ............................................................................................... 5
5 Packing Diagram .................................................................................................................. 6
5.1 X-ray Digital Radiography System (CXDI-60G/60C)................................................. 6
5.2 Grid (Optional)............................................................................................................. 8
6 Installation Procedures ......................................................................................................... 9
6.1 Lists of Tools Needed for Installation.......................................................................... 9
6.2 System Installation Procedures .................................................................................. 10
7 Installation .......................................................................................................................... 12
7.1 Connection to Each Unit ............................................................................................ 12
7.1.1 Connection Diagram ......................................................................................... 12
7.1.2 Connecting to the Power Box ........................................................................... 13
7.1.3 Using the Imaging Unit in the Multiple Rooms................................................ 19
7.1.4 Interchanging a Imaging Unit ........................................................................... 20
7.1.5 Sensor Cable (Optional).................................................................................... 22
7.1.6 Connection Diagram for Control Computer Rear Panel................................... 23
7.1.7 Adjusting the Length of the X-ray I/F Cable.................................................... 24
7.2 Starting up and Shutting down the System................................................................. 25
7.2.1 Sequence for Starting up the System ................................................................ 25
7.2.2 Sequence for Turning the Power off ................................................................. 25
7.3 X-ray Controller Interface .......................................................................................... 26
7.3.1 Interface Signal Description ............................................................................. 26
7.3.2 Signal Names and Functions in the Connection with the X-ray Generator ...... 28
7.3.3 Rating and Characteristics for Relay and Photo Coupler (on PWB-XRAY).... 30
7.4 Network Settings ........................................................................................................ 32
7.5 Setting the Fixed ROI Areas ...................................................................................... 35
7.6 Settings....................................................................................................................... 38
7.7 Image Quality............................................................................................................. 94
7.8 Post-installation Checks ............................................................................................. 96
8 Dimension .......................................................................................................................... 98

2. Installation
1
1 Caution During the Installation
Please pay attention to the followings when installing the system.
(1) If the equipment is hoisted, lowered or transported, it must be supported at both sides by a
minimum of two people so there is no danger of it falling.
(2) When installing the equipment, be sure the site meets the following criteria:
1) There must be no dripping water in the area.
2) The environment must be free of harmful elements such as humid or acidic air, air with
a saline or sulfur content, where there is poor ventilation or where air pressure or
temperature is unusual.
3) The equipment must not be placed at an angle or subjected to vibration or shock (this
includes during transportation).
4) The equipment must not be kept where chemical products are stored or where gasses are
generated.
5) The site’s power supply must be of the correct voltage and frequency for the equipment.
6) The site must be connected to a fully earthed cable with sufficient ground resistance to
meet standard values.
(3) After installation, be sure to dispose of waste product packaging with care and with full respect
for the environment.
2 Restrictions on Installation
(1) A clearance of at least 150mm must be left between a imaging unit and power box.
(2) It is forbidden to use the cables (Sensor cable, X-ray interface cable, etc.) from the power box
for moving parts. The only exception to this restriction is the sensor cable that is to be
connected to the imaging unit.

2. Installation
2
3 Caution on Installation
(1) Do not install the imaging unit near electronic devices as noises and artifacts tend to appear on
images in the electromagnetic field.
e.g. CRT monitor, X-ray generator, and any other medical electronic devices.
(2) Follow the following steps to detach the sensor cable while the system is running.
1) To detach the sensor cable
-Check the LED of the imaging unit and the display of the control computer to make
sure the status of communication between the imaging unit and control computer is
idle. (*1)
-Turn off the main power switch of the power box or the remote switch. (*2)
-Make sure the LED on the imaging unit, switch on the power box and remote switch
are turned off. Power supply to the Imaging unit must be disconnected.
-Detach the connector of the sensor cable.
*1: Do not detach the sensor cable during the data transmission between the imaging
unit and control computer, it may cause data loss, system error or equipment
breakdown.
*2: Do not detach the sensor cable when the power is being supplied from the power box,
it may cause equipment breakdown. If you disconnect the imaging unit by improper
steps, the “Error” LED on the power box and remote switch will be turned on to alert
you the sensor cable is detached improperly. To restore from the error, turn off the main
switch of the power box or the remote switch. Then connect the sensor cable again by
following the steps described in the next column.
2) To attach the sensor cable
-Make sure the LED on the imaging unit, switch on the power box and remote switch
are turned off. Power supply to the Imaging unit must be disconnected.
-Connect the connector of the sensor cable.
-Turn on both the main switch of the power box and remote switch.
(3) Before proceeding with installation, ensure that the static accumulated in the bodies of the
installation personnel is discharged. Similarly, before touching the PCBs (when removing
them) or cable connectors, ensure that all static is discharged.
(4) With the launch of CXDI-60C, the specification of the CXDI-60G sensor cable is changed to
conform to CXDI-60C. For details, refer to “7.1.4 Interchanging a Imaging Unit”.

2. Installation
3
4 Product Configuration
4.1 Product Configuration List
1) CXDI-60G/60C
No. Item Name Qty Remarks
1 CXDI-60G/60C Imaging Unit 1 with 1.5 m sensor cable
S150-60 ( imaging unit side)
2 Sensor cable P630 (power box side) 1 6.3m
3 Operation manual (for imaging unit)
4 Attached documents for medical (JPN)
5 Warranty registration (JPN)
6 Warranty card (US)
7 German Security leaflet/WEEE leaflet (EU)
2) CXDI SYSTEM II
No. Item Name Qty Remarks
1 Power Box 1
2 X-ray I/F cable 1 20m
3 Remote switch 1 20m
4 Power supply cable (with AC plug) 1 3m (100/120/230V)
5 Operation manual (for power box)
3) Sensor Cable (Optional)
No. Item Name Qty Remarks
1 Sensor Cable P630-PM (Panel mount type) 1 6.3m
2 Sensor Cable P70-60 (imaging unit side) 1 0.7m
3 Sensor Cable SP780-60 (Straight type) 1 7.8 m
LAN cable for connecting Control Computer / Power Box and Network switch (Switching HUB)
for connecting the multiple Imaging Units shall be procured at each sales company.
- LAN cable (Over category 5)
Recommended length of the cable is 30m or less.
When Control Computer and Power Box are connected directly, Cross type is used, but when
they are connected via Network switch, Straight type is used. However, this is not applied
when Network switch has AUTO-MDI/MDI-X function*.
- Network switch (Switching HUB)
Sales companies adopt Network switch (Switching HUB) after conducting the test and the
operation check for Switching HUB that meets the general standard.

2. Installation
4
4.2 Configuration
No. 1 No. 2
Name CXDI-60G/60C Imaging Unit Name Sensor cable P630
(Power box side)
Qty 1 Qty 1
Remarks Sensor cable S150-60
(imaging unit side) Remarks 6.3m
No. 3 No. 4
Name Power Box Name X-ray I/F cable
Qty 1 Qty 1
Remarks I/F and Power supply Remarks Connection with X-ray
generator
No. 5 No. 6
Name Remote switch Name Power supply cable
Qty 1 Qty 1
Remarks Switch to turn on and off
Power Box Remarks For Power Box
(100/120/230V each type)
This manual suits for next models
3
Table of contents
Other Canon Medical Equipment manuals

Canon
Canon Omnera 500A User manual

Canon
Canon CXDI-50G User manual

Canon
Canon Aplio i600 User manual

Canon
Canon CXDI-50C User manual

Canon
Canon Aplio-i Series User manual

Canon
Canon CXDI-50G User manual

Canon
Canon Omnera 500A User manual

Canon
Canon OMNERA 400T User manual

Canon
Canon CXDI-1 User manual

Canon
Canon OCT-A1 User manual
Popular Medical Equipment manuals by other brands

Getinge
Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics
Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care
Pressalit Care R1100 Mounting instruction

Denas MS
Denas MS DENAS-T operating manual

bort medical
bort medical ActiveColor quick guide

AccuVein
AccuVein AV400 user manual