Relief of cable strain Protection of the sensing face Switch mounted on mobile carrier
To avoid interference from inductive
voltage/ current peaks, separate the
prox. switch power cables from any
other power cables, e.g. motor,
contactor or solenoid cables The cable should not be
pulled
A proximity switch should not
serve as mechanical stop
Any repetitive flexing of the cable should
be avoided
Capacitive Level Sensors M12
Transistor Output with Teach-in
User Manual
Installation Hints
iring Diagram
15-029-506
TRIPLESHIELD™
Specifications
BN+
BK
WH
BU-
IOAD < 200 mA (CA12)
IA ARM
< 20mA
Teach-in
The PNP- or NPN-load will automatically be detected.
By means of the Teach-in wire, the functions described in the Teach-in
Guide can be set up.
It is possible to Teach-in more sensors at the same time by connecting
the H-wires in parallel to the common ”-” supply.
(#): Plug connections
(1)
(3)
(2)
(4)
Rated operational volt. (UB) 10 to 40 VDC (ripple incl.)
Ripple ≤ 10%
Rated operational current (Ie) ≤ 200 mA (continuous)
Output Transistor, NPN and PNP, NO and NC
(factory setting is NO)
Protection Reverse polarity, short-circuit, transients
TRIPLESHIELDTMprotection-EMC
IEC 1000-4-2/EN 61000-4-2 30 kV
IEC 1000-4-3/EN 61000-4-3 > 15 V/m
IEC 1000-4-4/EN 61000-4-4 3 kV
IEC 1000-4-6/EN 61000-4-6 > 10 Vrm
Rated operating distance
(Sn) 0 - 8 mm
Operating temperature
-20° --> +85°C (-4° --> +185°F)
Storage temperature
-40° --> +85°C (-40° --> +185°F)
Degree of protection IP 68
15-029-506_MAN M12 ENG_MAN M12 26-09-2012 13:46 Page 1
Teach Functions
Capacitive sensors have the unique ability to detect almost all materials,
liquid or
solid. Capa ci tive
sensors can detect metallic as well as non-metallic objects. How -
ever, their traditional use is for non-metallic materials such as:
•Plastic Industry: resins, regrinds or moulded products.
•Chemical Industry: cleansers, fertilisers, liquid soaps, corrosives and
petrochemicals.
•ood Industry: saw dust, paper products, door and window
frames.
•Ceramic & Glass Industry: raw material, clay or finished product, bottles.
•Packaging Industry: package inspection for level or contents, dry goods, fruits
and vegetables, dairy products.
Materials are detected due to their dielectric constant. The bigger the
size of an
object, the higher the density of material, the better or easier it is to de
tect the object.
Nominal sensing di stan ce for a capacitive sensor is referenced to a grounded me tal
plate (ST37). For addi tional information regarding di elec
tric ratings of materials
please
refer to our catalogue: “SENSORS”.
Installation
1. Mounting the sensor
Mount the sensor in the required position pointing at the target and make sure
that the distance to the target is within the range of the sensor.
2. Supplying the sensor
To supply the sensor, connect blue wire (3) to ground (0 VDC) and brown wire
(1) to + (10-40 VDC).
3. Programming the sensor
Program the sensor as described in the Teach-in guide. The following functions
are programmable: 1. Background adjustment and switch-point setup, 2. Object
adjustment, 3. NO/NC selection and 4. Restore factory settings (1. and 2. are
mandatory).
Description and Installation
Normal operation, optimized switching point.
1. Mount the sensor in the application without the object
present. Yellow ED is not important and green ED
is ON.
2. Press the button for 3 seconds until both EDs
are flashing simultaneously.
(The first switch point is stored)
3. Place the object in the detection zone.
4. Press the button once and the sensor is ready to
operate (green ED ON, yellow ED ON).
(The second switch point is stored).
If the object is too close to the background, the sensor will
perceive both background and object as object.
For maximum sensing distance
(default setting)
1. Mount the sensor in the application without the object
present. Yellow ED is not important and green ED is
ON.
2. Press the button for 3 seconds until both EDs
are flashing simultaneously.
(The first switch point is stored)
3. Press the button a second time and the sensor is
ready to operate (green ED ON, yellow ED ON)
(The second switch point is stored)
For dynamic set-up (running process)
1.ine up the sensor at the object. Green ED is ON,
status on the yellow ED is not important.
2.Press the button for 3 seconds until both EDs are flashing
simultaneously.
3. Press and hold the button a second time for at least
one second (both EDs are flashing simultaneously and fast)
and keep the button pressed for at least one process
cycle. Release the button and the sensor is ready to
operate (The second switch point is stored).
If more process cycles are analysed, a more precise
setting is possible.
For make or break set-up (N.O. or N.C.)
1. Press the button for 10 seconds, until the green ED
flashes.
2. While the green ED flashes, the output is inverted
each time the button is pressed. Yellow ED indicates
N.O. function selected.
If the button is not pressed within the next 16
seconds, the current output is stored.
Factory settings
Press the button for 16 sec.
124
3sec. Push once
3
1 3
3 sec. Push once
2
13
3 sec. One cycle
2
2
10 sec. Push once
1
Dimensions
CA12CLC08BPRT
CA12CLC08BPM1RT
M12 x 1 LED
10.7
82.4
19.4
50
M12 x 1 LED M12
10.7
84.7
18.450
Teach
button
15-029-506_MAN M12 ENG_MAN M12 26-09-2012 13:46 Page 2

This manual suits for next models

2

Other CARLO GAVAZZI Accessories manuals

CARLO GAVAZZI PD30CTP/R BP IO Series User manual

CARLO GAVAZZI

CARLO GAVAZZI PD30CTP/R BP IO Series User manual

CARLO GAVAZZI SBPSMWBAT User manual

CARLO GAVAZZI

CARLO GAVAZZI SBPSMWBAT User manual

CARLO GAVAZZI LD30 BI10BP IO Series User manual

CARLO GAVAZZI

CARLO GAVAZZI LD30 BI10BP IO Series User manual

CARLO GAVAZZI SMS Series User manual

CARLO GAVAZZI

CARLO GAVAZZI SMS Series User manual

CARLO GAVAZZI SBPSUSL45 User manual

CARLO GAVAZZI

CARLO GAVAZZI SBPSUSL45 User manual

CARLO GAVAZZI M18 Series Technical specifications

CARLO GAVAZZI

CARLO GAVAZZI M18 Series Technical specifications

CARLO GAVAZZI MC36C User manual

CARLO GAVAZZI

CARLO GAVAZZI MC36C User manual

CARLO GAVAZZI SBPSUSL45 User manual

CARLO GAVAZZI

CARLO GAVAZZI SBPSUSL45 User manual

CARLO GAVAZZI SBPOCC24 User manual

CARLO GAVAZZI

CARLO GAVAZZI SBPOCC24 User manual

CARLO GAVAZZI SBPBASEB User manual

CARLO GAVAZZI

CARLO GAVAZZI SBPBASEB User manual

CARLO GAVAZZI CB32 Series User manual

CARLO GAVAZZI

CARLO GAVAZZI CB32 Series User manual

CARLO GAVAZZI PD30CTB BP Series User manual

CARLO GAVAZZI

CARLO GAVAZZI PD30CTB BP Series User manual

CARLO GAVAZZI RAD User manual

CARLO GAVAZZI

CARLO GAVAZZI RAD User manual

CARLO GAVAZZI PD140 User manual

CARLO GAVAZZI

CARLO GAVAZZI PD140 User manual

CARLO GAVAZZI SBPBASEA User manual

CARLO GAVAZZI

CARLO GAVAZZI SBPBASEA User manual

CARLO GAVAZZI DLI-P360L M Series User manual

CARLO GAVAZZI

CARLO GAVAZZI DLI-P360L M Series User manual

CARLO GAVAZZI DLI-P360L24MF User manual

CARLO GAVAZZI

CARLO GAVAZZI DLI-P360L24MF User manual

CARLO GAVAZZI GP62x022xx724-US Series User manual

CARLO GAVAZZI

CARLO GAVAZZI GP62x022xx724-US Series User manual

CARLO GAVAZZI CD34 User manual

CARLO GAVAZZI

CARLO GAVAZZI CD34 User manual

CARLO GAVAZZI ROG400 User manual

CARLO GAVAZZI

CARLO GAVAZZI ROG400 User manual

CARLO GAVAZZI CD34CNFLF Series User manual

CARLO GAVAZZI

CARLO GAVAZZI CD34CNFLF Series User manual

CARLO GAVAZZI PVS1V User manual

CARLO GAVAZZI

CARLO GAVAZZI PVS1V User manual

CARLO GAVAZZI UA 30 CLD User manual

CARLO GAVAZZI

CARLO GAVAZZI UA 30 CLD User manual

CARLO GAVAZZI UC80CND80 User manual

CARLO GAVAZZI

CARLO GAVAZZI UC80CND80 User manual

Popular Accessories manuals by other brands

Gaggenau CA 060 300 user manual

Gaggenau

Gaggenau CA 060 300 user manual

Torbal AD Series Quick reference guide

Torbal

Torbal AD Series Quick reference guide

Niles IE6 Specification sheet

Niles

Niles IE6 Specification sheet

Delphi SA50004 - SKYFi Home Adaptor Quick installation guide

Delphi

Delphi SA50004 - SKYFi Home Adaptor Quick installation guide

AromaTech AroMini Deluxe user manual

AromaTech

AromaTech AroMini Deluxe user manual

Behringer F-Control Audio FCA202 operating manual

Behringer

Behringer F-Control Audio FCA202 operating manual

ORION TELESCOPES & BINOCULARS 10110 instruction manual

ORION TELESCOPES & BINOCULARS

ORION TELESCOPES & BINOCULARS 10110 instruction manual

Vega VEGASON 61 operating instructions

Vega

Vega VEGASON 61 operating instructions

Clearaudio TT3 user manual

Clearaudio

Clearaudio TT3 user manual

PCB Piezotronics 393B04 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 393B04 Installation and operating manual

Byron 1217 Installation and operation instruction

Byron

Byron 1217 Installation and operation instruction

Salus WLS600 quick guide

Salus

Salus WLS600 quick guide

Paramount Fitness Ultra UV2 Replacement instructions

Paramount Fitness

Paramount Fitness Ultra UV2 Replacement instructions

Waterpik WP-105 manual

Waterpik

Waterpik WP-105 manual

ZooZ ZSE40 700 user manual

ZooZ

ZooZ ZSE40 700 user manual

turck RU Series Instructions for use

turck

turck RU Series Instructions for use

Dynafit CRAMP-IN user manual

Dynafit

Dynafit CRAMP-IN user manual

Q-FREE MD 5850 MultiReader installation manual

Q-FREE

Q-FREE MD 5850 MultiReader installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.