CAS PB Series User manual

Presented By
Dallas HoustonAustinFt Worth
NicolScales.com
800.225.8181
Contact Us
Nicol Scales & Measurement is an ISO Accredited Calibration
Company that has provided calibration, repair and sales of all types
of weighing and measurement products since 1931.

2

3
CONTENTS
PRECAUTIONS.................................................. 4
PREFACE ............................................................... 6
NAMES AND FUNCTIONS.......................... 6
ASSEMBLY & SETTING............................... 7
OPERATIONS...................................................... 8
1. Simple Weighing Mode ..................................... 8
2. Weighing with Tare............................................ 9
3. Hold Function..................................................... 9
4. Setup Mode ....................................................... 10
5. How to use print(Option).................................11
BATTERY MAINTENACE......................... 16
ERROR MESSAGE......................................... 16
SPECIFICATIONS .......................................... 17

4
PRECAUTIONS

5
PRECAUTIONS

6
PREFACE
Thank you for purchasing CAS PB(Portable Bench).
These series have been designed with CAS reliability, under rigid quality control
and with outstanding performance. Your special departments can enjoy these
high quality reliable CAS products.
We believe that your needs will be satisfied and you will have proper reliability.
This manual will help you with proper operation and care of the PB(Portable Bench).
Please keep it handy for future reference.
NAMES AND FUNCTIONS
OVERALL VIEW
DISPLAY & KEYBOARD
■PB(LCD)

7
■KEY FUNCTIONS
KEYS FUNCTIONS
Used to set the zero point.
Used to input or cancel the weight of tare.
Used to make the weight of commodity stable.
This weight is average value.
Used to turn on/off the scale or backlight. (If you press the button long
time, Power is turned off)
ASSEMBLY & SETTTING
■If you unscrew a bolt at Bracket handle( ), you can separate the indicator(①).②
■Please Unscrew a limit bolt(M6 X 10), before Use a scale.

8
OPERATIONS
■Turn on the display by pressing key. Then, the display will show all the segments and
count up "0" to "9". You may stop this automatic counting by pressing the key.
■When you turn on the display, make sure that platter is empty. Otherwise, display will show
"Err 1", an error of initial zero range. Please refer to "ERROR MESSAGE" section for
more information on page 16
■When the weight becomes stable the display shows the stable sign ( ○) on.
■You may need to make it "0.00" by pressing key unless the display indicate "0.00"
under the empty platter.
1. Simple Weighing Mode
①Place a commodity on
the platter. ②Remove the commodity
from the platter.

9
2. Weighing with Tare
■TARE means the weight of container being used for a commodity.
■TARE key function is to subtract the weight of the container from full weight loaded.
Place a container on①
the platter. ②Press the key. then
display will show the "0.00". ③Place a commodity into
the container, then the
display will show only the
weight of the commodity.
④Remove container and
commodity, then the display
will show the weight of the
container with "-" symbol.
⑤Press the key, then
display will show the "0.00".
3. Hold Function
①When the weight is
unstable, press the key.
②"HOLD" will be displayed
twice
③Then average value will be
show twice And the "HOLD"
function will be removed
automatically

10
4.SETUP MODE
4-1. How to Go to Setup Mode
Make sure that power is OFF. While pressing the ZERO key, press the key. The display shows “U
SEt”. You can select each menu by pressing the ZERO key and change the setting by pressing the
TARE key. If you press ZERO key, you can save current setting and go next mode.
4-2. Set up Mode Table
MENU DISPLAY DESCRIPTIONS
“noSnd” Do not use printer. (No Send Mode)
“K-Snd” Push the key , Print out. (Command Mode)
“S-Snd” Weight is Stable, Print out. (Stable Mode)
“U-Snd” Print out, continuously. (Continue Mode)
Printer
“C-Snd” Weight is changed, Print out. (Change Weight Mode)
“
AP oFF ” Do not useAuto Power Off function.
“AP 10 ” Power turns to be off automatically when the scale is
not in operation over for 10 minutes.
“AP 30 ” Power turns to be off automatically when the scale is
not in operation over for 30 minutes.
Auto Power Off
“AP 60 ” Power turns to be off automatically when the scale is
not in operation over for 60 minutes.
“bLon ” Use back-light.
“bL10 ” Back-light is on 10 seconds.
“bL30 ” Back-light is on 30 seconds.
Backlight
“
bL oFF ” Do not use back-light.
Brightness “1~7” Youcan set backlight brightness. (Default :3)
Italic Bold : Default Setting
※

11
5. How to Use Print (Option)
5-1. Mode Change
You can use print out function. Print Out Mode has total 5 stage.
Each Stage is “NOSEND, K-SEND, S-SEND, U-SEND, C-SEND
5-2. K-Send
1)Mode Setting
- This Print Mode is ‘Command Mode’. First of all, You must scale’s mode setting.
Please refer to the page 10.
2)Print Opreation
①Place a commodity on the
platter, then the display will
show the weight of the
commodity.
②If you press the key,
You can see the “SUM”
message and Current weight
and then you can send the
weight to the printer.
③Place a another
commodity on the platter,
④Press the key, You
can send the another weight
to the printer.
⑤Remove container and
commodity, then display will
show the"0.00".
⑥Press the key, Total
weight is send a printer.

12
3)Print Out
5-3. S-Send
1)Mode Setting
- This Print Mode is ‘Stable Mode’. Please refer to the page 10.
2)Print Opreation
3)Print Out
①Place a commodity on the
platter, then the display will
show the weight of the
commodity.
②If weight is stable state,
You will see on display
and then you listen to the
buzzer sound one time.
③Remove container and
commodity, then You can
print another commodity
weight.
K-send MODE
=>Command Mode
Count Weights/kg
1 25.80
2 19.50
----------------
Sum Total 45.30
S-SEND MODE
=> Stable Mode
25.80

13
5-4. U-Send
1)Mode Setting
- This Print Mode is ‘Continue Mode’. Please refer to the page 10.
2)Print Opreation
①Place a commodity on the
platter, then the display will
show the weight of the
commodity. The weight is
send to the printer continually.
②Remove container and
commodity, then display will
show the"0.00".
3)Print Out
U-SEND MODE
=> Continue Mode
25.80
25.80
25.80
25.80
0.00
0.00
0.00
0.00

1
4
5-5. C-Send
1)Mode Setting
- This Print Mode is ‘Change weight Mode’. Please refer to the page 10.
2)Print Operation
3)Print Out
①Place a commodity on the
platter, then the display will
show the weight of the
commodity.
②Remove container and
commodity, then display will
show the"0.00". While weight
is change, The weight is
send to the printer.
C-SEND MODE
=> Change weight Mode
0.00
7..32
16.25
25.80
19.95
9.92
3.15
0.00

15
5-6. How to Connect RS-232C Wire
- SERIAL INTERFACE(Scale <-> Printer)
- SERIAL INTERFACE(Scale <-> PC)

16
BATTERY MAINTENACE
LOW BATTERY WARNING
When the battery is low the display shows the “ ” sign.
You can replace the battery new one.
If you still use the scale without replacing the battery the scale may provide
incorrect result on measurement.
※Low Battery Status. ※ Battery cut off display.
ERROR MESSAGE
Error Message
on Display
Description Solution
"Err 0" The "Err 0" occurs when scale is not stable. Remove unstable
facts.
"Err 1" The "Err 1" occurs when a current zero point has
shifted from the last span calibration. Please call your CAS
dealer.
"Err 3" The "Err 3" is an overload error. Please remove the
weight.
"Err 9"
The "Err 9" is no weight error. When scale is in
counting mode, you must load the weight.
If you have no weight on your scale, you can see
this error message.
Please load the
weight on your tray.

1
7
SPECIFICATIONS
MODEL PB(LCD)
Capacity / e Dual Interval
Max15/30kg
e=5/10g
Dual Interval
Max 30/60kg
e=10/20g
Dual Interval
Max 60/150kg
e=20/50g
Dual Interval
Max 100/200kg
e=50/100g
Internal
Resolution 1/60000 1/60000 1/60000 1/60000
External
Resolution 1/3000 1/3000 1/3000 1/2000
MAX Tare -14.995kg -29.99kg -59.98kg -99.95kg
Display 134 x 48.6[mm]/52.7" x 19.1" 6digit LCD
Symbols STABLE, ZERO, TARE, g, kg, lb, oz, Low Battery
Keys ZERO, TARE, HOLD, POWER
Functions
Weighing Hold Function
Backlight ON/OFF(Bright) Control Function
Auto Power Off Function
Print out Function
Dimensions 355(W) x 611(D) x 65(H)[mm] / 140(W) x 241(D) x 256(H)[inch]
Platter size 355(W) x 443(D)[mm] / 140(W) x 174(D)[inch]
Weight 6.0kg
Power 1.5V x 4 units (C size Battery)
Operation
Time Approx. 140hours (Manganese battery)/
300hours (Alkaline at 20°C /68°F)
Operating
Temperature -10°C ~ +40°C / 14°F ~ 104°F
Minimum
Voltage
Level of The
Battery
About 4.2V(Recharge Battery: 5.6V)
Option
12V Adaptor 1.5A
RS-232C(RJ-11 TO D-SUB) Wire (Add Serial Interface)
DEP-50 Printer (Add Serial Interface)
Recharge battery(Pb:6V, 1.3Ah, 20HR) (Add Recharge Interface)
Notice: Specificati※ons are subject to change for improvement without notice.

1
8
MEMO

19

20
Other manuals for PB Series
1
Table of contents
Other CAS Scale manuals