09/10/09CAS (USA) Corporation 99 Murray Hill Parkway East Rutherford, NJ 07073 PD-II
PROGRAMMING LBS/OZ FOR PD-II CAL MODE OPTIONS
1. Make sure that the scale is off. Remove the platter. Remove the calibration bolts and plate
located on the top front of the scale.
2. After removing the calibration bolts and plate you will see a white micro switch at the bottom of
the hole. Press and hold down the micro switch and turn on the scale.
3. The display will read “CAL” → “Ver XXX “→ “C-0 “. Release the micro-switch. Press the [ # ]
key until the display shows “C-4 “. Replace the platter. ( “ # “ is to increase and “lb/oz“is to
decrease the value )
4. Press the [ ZERO ] key and display should read “C41 XX “. Press [ ZERO ] to go to the next
step “ C42 XX “ → “ C43 XX “ → “C44 XX “ → “ C45 XX “ → “ C46 XX “.
5. Depending on the capacity and function, enter the value “XX “step by step. Press “# “to move
the digit and “* or lb/oz “to change the value. ( see chart below)
6. Note: For the setting “C42” for all capacities single range is “38” and dual range is what is in the
chart below.
7. The settings for the capacity and single/dual range must follow what is on the serial number plate
or else the scale will not be NTEP or legal for trade subject to a fine by Weights and Measures.
8. Press the [ ZERO ] key. Display shows “C4 End “then “C-4 “.
9. Press “* or lb/oz “until the display shows “C-0 “.
Starts up in lb and can be switched to oz
Starts up in oz and can be switched to lb
Starts up in lb and will not switch to oz
Starts up in oz and will not switch to lb