5
ENGLISH
Be sure to use enough sealant between the ange and roof to ensure no water ingress. Roof feed-
through is in material quality EN 1.4016. Take necessary precautions to avoid galvanic corrosions.
Fasten roof feed-through ange with appropriate stainless-steel screws.
INLET AIR
An inlet air hose is included in the installation box. Use a
3 17/32” (83 mm) hole saw for implementation in ooring. An
optional oor nozzle is available for double oors. Consider
air supply into double oor compartment for sucient air
ow. When installing inlet air with the hose, fasten the metal
air inlet cassette delivered with the appliance to the bottom
of the build in module and fasten the hose to this cassette.
If the wheel arch or other obstructions prevent the hose
from going directly down, it can be bypassed, but make sure
the hose is routed with gentle bends and as short a stretch
as possible, maximum hose length 47 in. (120 cm) Finish with
oor nozzle under oor exterior. The hose may be insulated, if desired.
An air grate can be used in both oor and wall, but make sure you have a minimum 50 cm² light
opening and that you protect against water intrusion. Please note that oor intake is preferred
instead of wall intake. If the toilet in large parts of the year is used in cool climates that experience
extreme cold for extended periods, condensation may form on the outside of the toilet. It may be
advantageous to preheat the air in. This can be done using a radiator connected to the heating system
that preheats the air.
GAS INSTALLATION
Illustration 2
Beskr.: Gas hose marking / sticker
Dato: 22.01.2020
Ø 17 mm
INSPECTION HATCH
There must be access to the top of the Build-in module
for easy access to connections. This allows for annual
inspection and leak testing of the gas connection.
CONTROL PANEL
Locate the desired placement of the control panel.
Create an opening for the signal cable and route the
cable out here. The signal cable is a at cable with
approx. 25/32” (20 mm) width. Connect the signal cable
together with the control cable and fasten the control
panel. The signal cable can be connected in two ways,
but only one way is correct. If you get a red light, and
not a green, reconnect signal cable the opposite way. The
signal cable is approx. 60 in. (150 cm) long.
NOTICE!
Please note that a sticker is delivered with the toilet for marking
of the gas shut-o valve and this sticker is mandatory in some countries.
Please be aware that regulations regarding gas installations in vehicles vary from country to
country. The installation may require certied personnel in order to be approved. Be sure to
research the local regulations where you live and adhere to these before installation.
The gas is supplied through an 8 mm pipe directly to the toilet with an angled compression tting on
top of the Build-in module. No adjustment of tting is allowed. The toilet is designed to run on propane.
If you know that you frequent areas with low quality propane, a lter should be considered. A separate
gas shut-o valve is required when connecting to an existing gas supply line.
This will aid trouble shooting and allow operation of other appliances in case the toilet is dismounted.
The connector is a brass compression coupling which takes Ø 8 mm pipe. Be sure to clamp the pipe
close to the tting to avoid stress fatigue in the pipe.
Illustration 3