manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cleveland
  6. •
  7. Electric Steamer
  8. •
  9. Cleveland ConvectionPro XVI 36-CEM-16-48 User manual

Cleveland ConvectionPro XVI 36-CEM-16-48 User manual

Cleveland
™
Project ________________________________
Item __________________________________
Quantity _______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
CLASSIC CONVECTION STEAMERS
15 PSI BOILER BASE STYLE
SECT. III PAGE 25
0707
MODEL: c36-CEM-16-48
Cleveland Standard Features
nCooking Capacity for up to eight 12˝ x 20˝ x 21⁄2˝ deep
Cafeteria Pans per compartment, or four 12˝ x 18˝ Buns
Pans.
nPressureless cooking with forced convection steam,
permitting doors to be opened while cooking continues.
n
Solid State Controls operate water level and safety functions.
n
Each compartment is equipped with a 60 minute mechanical
timer, separate bypass switch for constant steaming and a
cold water condenser for superior cooking results.
nInstant Steam Standby Mode: Holds generator at steam-
ing temperature. Allows unit to start cooking instantly.
nDurable 10 Gauge Stainless Steel Construction:
For Compartment Door and Steam Cooking Cavity.
nSeparate Main Power Switch for “On/Off”
nExclusive Steam Cooking Distribution System: The
exclusive Convection Jets produce a high velocity
convection steam without fans. Coved Corner design in
cooking compartment distributes heat evenly and is easy to
keep clean. Creased bottom enhances drainage. Cold
Water Condenser for each compartment maintains a dry
steam. Fully insulated cooking compartment for thermal
efficiency. Removable Stainless Steel Slide Racks for easy
cleaning.
nHeavy duty, one piece, solid compartment door design
with replaceable door gasket.
nLeft Hand Door Hinging: Compartment Doors hinged left,
controls on the right.
nModular Cabinet Base with Hinged Door.
nHeavy duty Stainless Steel Base Frame.
n
Electric Steam Generator: Automatic Water Fill on start up.
nAutomatic Generator Drain at shutdown: Contains a
“Water Jet” Spray Rinse Cleaning Cycle to keep drain clear.
nAutomatic Water Level Control System with Low Water
Power Cut-off Circuit.
nSteam generator equipped with High Limit Pressure Safety
Switch, 15 psi Safety Valve, and Steam Generator Pressure
Gauge.
nSecondary Low Water Cut-Off, factory installed (CALE)
(Required for AZ. AR. CA. CO. CT. DE. FL. GA. HI. IL. IA. KS. MD. MA. MI.
MN. MT. NE. NV. NM. NC. OK. OR. PR. RI. TN. UT. VA. WA. WV., Buffalo,
NY, Wash. DC)
nNSF Certified 6˝ Stainless Steel Legs with adjustable
flanged feet for a one inch level adjustment.
Shall be Two Large Compartments, CLEVELAND Convection Steamer,
Model 36-CEM-16-48, 48 KW Electric; _____ volts, _____ Hz, _____ phase, 3
wire. Solid State Controls operate timing, water level and safety
functions.Type 304 Stainless Steel cooking compartment. Insulated cooking
compartments. One 60 minute Mechanical Timer with Touch Control per
compartment. Audible and Visual Signals for completion and steam shut-off.
nStandard voltage 208 or 240 volts, 60 Hz, 3 phase.
nAll Controls are serviceable from the front.
nCompartment Door Steam Shut Off Switch.
Options & Accessories
pElectronic Timer with Compensating Load Feature. (ETC)
pON/OFF Steam Switch only for compartment controls (MC)
pCafeteria pans in depths of 1˝, 21⁄2˝, 4˝ and 6˝
p12˝ x 18˝ Bun Pans
pVoltages other than standard (see back page)
pCorrectional Packages
pBoiler Descaling Pump Kit (107142)
pWater Filters
Short Form Specifications
Shown with optional
Electronic Timer
ConvectionPro XVI ®
TWO LARGE COMPARTMENTS, PRESSURELESS
48 KW ELECTRIC STEAM GENERATOR
36” WIDE CABINET BASE DESIGN
CONVECTION
STEAMERS
(NOT TO SCALE)
SECT.III PAGE 26
0707
Litho in U.S.A
•Each compartment has capacity for:
Eight, 12˝ x 20˝ x 21⁄2˝deep Cafeteria Pans. Can
accomodate 18˝ x 26˝ Bun Pans.
•Many regional, state and local codes exist and it is the
responsibility of the owner and installer to comply with
those codes.
•Cleveland Range equipment is built to comply with
applicable standards for manufacturers. Included
among those approval agencies are: UL, A.G.A.,
NSF, ASME/N.Bd., CSA, CGA, ETL, and others.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours of
use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY less than 20 parts per million
SILICA less than 13 parts per million
pH FACTOR greater than 7.5
CHLORINE less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals. The
use of highly mineralized water will mean that more frequent
servicing of the steam generator will be necessary. The fact
that a water supply is potable is not proof that it will be
suitable for the generator.
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are ASME/N. Bd, UL/NSF#4 and CSA.
KW Volts Watts Ph Amps Wire
48 208 42,900 3 119.2 3
220 48,000 3 126.1 3
240 48,000 3 115.6 3
440 40,300 3 52.9 3
480 48,000 357.8 3
600 48,000 346.2 3
360 42,900 3 68.9 4
380 48,000 373.0 4
415 48,000 366.9 4
ELECTRIC WATER DRAINAGE CLEARANCE
C
D
The Floor Drain must be located
outside the confines of the
equipment base.
1 1/2˝ I.P
.S. common drain.
Do not connect other units to this drain.
Do not use PVC pipe for drain.
Cold Water Inlet
35 psi minimum
60 psi maximum
1/4˝ NPT
Condenser feed
3/8˝ NPT Boiler
feed
Right - 3”, Left - 3”,
Rear - 3” (12” on control
side if adjoining wall or
equipment is over 30” high
for service access)
Contact factory for
variances to clearances.

Other manuals for ConvectionPro XVI 36-CEM-16-48

1

Other Cleveland Electric Steamer manuals

Cleveland SteamCraft 21-CGA-5 User manual

Cleveland

Cleveland SteamCraft 21-CGA-5 User manual

Cleveland 42-CKGM-200 User manual

Cleveland

Cleveland 42-CKGM-200 User manual

Cleveland SteamChef 22CET6.1 User manual

Cleveland

Cleveland SteamChef 22CET6.1 User manual

Cleveland SteamCub 1SCEMCS Owner's manual

Cleveland

Cleveland SteamCub 1SCEMCS Owner's manual

Cleveland PDL-3 User manual

Cleveland

Cleveland PDL-3 User manual

Cleveland CET-5 User manual

Cleveland

Cleveland CET-5 User manual

Cleveland 24-CGA-10.2 User manual

Cleveland

Cleveland 24-CGA-10.2 User manual

Cleveland 22CGT66 User manual

Cleveland

Cleveland 22CGT66 User manual

Cleveland PGM-200-2 User manual

Cleveland

Cleveland PGM-200-2 User manual

Cleveland 24-CGA-6 User manual

Cleveland

Cleveland 24-CGA-6 User manual

Cleveland 24-CGA-10.2 User manual

Cleveland

Cleveland 24-CGA-10.2 User manual

Cleveland 22CET3A User manual

Cleveland

Cleveland 22CET3A User manual

Cleveland 21CET16 User manual

Cleveland

Cleveland 21CET16 User manual

Cleveland CA1-E User manual

Cleveland

Cleveland CA1-E User manual

Cleveland SteamChef 3 User manual

Cleveland

Cleveland SteamChef 3 User manual

Cleveland 42-CKEM-24 User manual

Cleveland

Cleveland 42-CKEM-24 User manual

Cleveland SteamCub 1SCE User manual

Cleveland

Cleveland SteamCub 1SCE User manual

Cleveland Convotherm OGB-12.20 User manual

Cleveland

Cleveland Convotherm OGB-12.20 User manual

Cleveland 24-CGA-10.2 User manual

Cleveland

Cleveland 24-CGA-10.2 User manual

Cleveland OES-6.10 User manual

Cleveland

Cleveland OES-6.10 User manual

Cleveland SteamChef 3 User manual

Cleveland

Cleveland SteamChef 3 User manual

Cleveland SteamCraft 10 User manual

Cleveland

Cleveland SteamCraft 10 User manual

Cleveland 24-CGM-200 User manual

Cleveland

Cleveland 24-CGM-200 User manual

Cleveland 24-CDP-10 User manual

Cleveland

Cleveland 24-CDP-10 User manual

Popular Electric Steamer manuals by other brands

Cuizimate RBSEGGBOILNEW instruction manual

Cuizimate

Cuizimate RBSEGGBOILNEW instruction manual

Wolf IS15/S installation instructions

Wolf

Wolf IS15/S installation instructions

Rational CPC Series installation manual

Rational

Rational CPC Series installation manual

Vulcan-Hart C24EA10 Replacement parts catalog

Vulcan-Hart

Vulcan-Hart C24EA10 Replacement parts catalog

Unold MINI ALLROUND Instructions for use

Unold

Unold MINI ALLROUND Instructions for use

EmberGlo ES5 Series Installation service

EmberGlo

EmberGlo ES5 Series Installation service

WAGNER SteamStation W1500P manual

WAGNER

WAGNER SteamStation W1500P manual

Saturn ST-EC1182 manual

Saturn

Saturn ST-EC1182 manual

Top Innovations SF-450 user manual

Top Innovations

Top Innovations SF-450 user manual

Mienta Trio ST16103A instruction manual

Mienta

Mienta Trio ST16103A instruction manual

Steba DG 2 Instructions for use

Steba

Steba DG 2 Instructions for use

TECHWOOD TCV-372 instruction manual

TECHWOOD

TECHWOOD TCV-372 instruction manual

Groen HyPlus HY-6S Series Operator's manual

Groen

Groen HyPlus HY-6S Series Operator's manual

Kalorik USK DG 1 operating instructions

Kalorik

Kalorik USK DG 1 operating instructions

Rasonic RSB-B2TW Operation manual

Rasonic

Rasonic RSB-B2TW Operation manual

cecotec Vapovita 3000 Inox instruction manual

cecotec

cecotec Vapovita 3000 Inox instruction manual

Morphy Richards FOOD STEAMER 48780 manual

Morphy Richards

Morphy Richards FOOD STEAMER 48780 manual

Scarlett SC-1142 instruction manual

Scarlett

Scarlett SC-1142 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.