Cleveland TMKEL-100-T User manual

Cleveland
™
Project ________________________________
Item __________________________________
Quantity_______________________________
FCSI Section ____________________________
Approval _______________________________
Date __________________________________
1333 East 179 St.,
Cleveland, Ohio,U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site:www.ClevelandRange.com
Email: Steam@ClevelandRange.com
MIXER KETTLES
TWIN MIXER KETTLE, ELECTRIC
LEG MOUNTED, CONSOLE TYPE
2/3 JACKETED, TILTING
MODELS:cTMKEL-40-T cTMKEL-80-T
cTMKEL-60-T cTMKEL-100-T
Cleveland Standard Features
nSolid State Temperature Control (±1°F) for perfect
simmering
nSolid State Low Water Safety Control
nSteam Jacket filled with treated water, venting and/or refilling
not required
n50 psi Safety Valve and Steam Jacket Rating
nNo Water Gauge required
nRear mounted Pressure/Vacuum Gauge and Pressure Relief
Valve
nInfinitely Variable Scraper Speed Control from 0-40 rpm
nInfinitely Variable Ratio between Scraper And Agitator:
Agitator rotates from 0-8 times the speed of the Scraper
nRemovable (without tools) Nylon Blades scrape entire
Jacketed surface
n3Horsepower Hydraulic powered Agitator, Scraper and
Bridge Lift
nSafety Device prevents high speed starts
nMixer stops when Bridge is lifted
nAgitator and Scraper are bayonet mounted for easy removal
nTilt mechanism of Roller Bearings and case hardened self-
Locking worm and segment gear
nHot and Cold Water Faucets
n2" diameter Tangent Draw-Off Valve with Drain Strainer
nAll Plumbing, Electrical and Hydraulics enclosed in Stainless
Steel Consoles
nEnclosed, 10 Gauge Stainless Steel hydraulically operated
Mixer Bridge
nKettle and all Exterior surfaces are Stainless Steel
nLevel adjustable feet (flanged for bolting)
nLarge Pouring Lip
nGallon Markings stamped into Scraper Shaft
nStandard 208-240 volts, 60 Hz, 3 phase, 4 wire, high wattage
nTypical approvals include UL., CSA, CE, NSF and ASME
Options & Accessories
pCovers (MPT)
pProduct Time/Temperature Controls and Indicators
pFood Strainer (FS-20)
pFlow Diverter (FD)
pPan Carrier (PCK)
pSwing Funnels (SF-1 or SF-2)
pAlternate Mounting Systems (wall)
Shall be CLEVELAND, Model TMKEL- _____ -T,console/Leg mounted,
Electric Mixer KettleS with permanently filled Steam Jackets; 50 psi Kettle
Jacket Ratings and Safety Valves, High Wattage standard, Solid State
Temperature (±1°F) and Low Water Safety Controls.
3H.P
. H
ydraulic pow-
ered Scraper/Agitator and Bridge Lift. 0-40 rpm Scraper Speed with Variable
Scraper to Agitator Ratio from 1-1 to 8-1. Stainless Steel enclosed Mixer
Bridge. All Plumbing, Electrical and Hydraulics enclosed in Consoles. Gallon
Markings. Safety Device prevent high speed starts.
Safety Device prevents
high speed starts; Mixer stops when Bridge is lifted.
Bayonet Mounted
Agitator and Scraper. 2" Tangent Draw-0ff Valve. Hot and Cold Water Faucet.
Kettle and all exterior surfaces are Stainless Steel.
pPower Tilt (PT)
pKettle Accessory Kit (KAK) includes:
pClean-up Brush (CB) p36˝ Kettle Paddle (KP)
p36˝ Kettle Whip (KW) p36˝ Kettle Brush (KB)
pDraw-off Brush (DB) p24 oz. Ladle (KL)
pType 316 Stainless Steel Interior for high acid food
products (316-20G)
pWater Meter (GMF or LMF) Wall Mount or on Stand (SWM)
pLeg Extensions (ELTMK)
pVoltages (VOS) other than standard
ShortFormSpecifications
SECT. XI PAGE 7
0707
Shown with optional Power Tilt
SECT. XI PAGE 8
0707
Litho in USA
(NOT TO SCALE)
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Installation of backflow preventers, vacuum breakers and other specific coder requirements is the responsibility of the owner and installer.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are U.L., A.G.A., NSF, ASME/N.Bd., CSA, CGA, ETL and others.
L 200 3 3 60 22684 81.6 3
R 200 3 3 60 22684 65.5 4
L208 3360 24535 83.8 3
R208 3 3 60 24535 68.1 4
L 220 3 3 60 27448 87.1 2
R 220 3 3 60 27448 72.0 3
L 230 3 3 60 30000 90.0 2
R 230 3 3 60 30000 75.3 3
L240 33 60 32665 92.8 2
R 240 3 3 60 32665 78.6 3
L 380 3 3 60 25153 47.1 6
R380 3360 25153 38.2 6
TMKEL-40-T
Kettle
(Left/Right)
Supply
Voltage
Phase
Wires
HZ
Total
Wattage
Supply
Amps
Wire Size
L 400 3 3 60 27871 48.8 6
R 400 3 3 60 27871 40.2 6
L415 3360 30000 50.1 6
R415 3 3 60 30000 41.7 6
L 440 3 3 60 27448 44.1 6
R 440 3 3 60 27448 36.0 8
L 480 3 3 60 32665 46.9 6
R 480 3 3 60 32665 39.3 6
TMKEL-40-T
Kettle
(Left/Right)
Supply
Voltage
Phase
Wires
HZ
Total
Wattage
Supply
Amps
Wire Size
L 200 3 3 60 27221 94.7 2
R 200 3 3 60 27221 78.6 3
L208 3360 29442 97.4 1
R208 3 3 60 29442 81.7 3
L 220 3 3 60 32938 101.5 1
R 220 3 3 60 32938 86.4 2
L 230 3 3 60 36000 105.0 1
R 230 3 3 60 36000 90.4 2
L240 33 60 39198 108.5 1
R 240 3 3 60 39198 94.3 2
L 380 3 3 60 30184 54.7 6
R380 3360 30184 45.9 6
TMKEL-60-T, TMKEL-80-T, TMKEL-100-T
Kettle
(Left/Right)
Supply
Voltage
Phase
Wires
HZ
Total
Wattage
Supply
Amps
Wire Size
L 400 3 3 60 33445 56.8 4
R 400 3 3 60 33445 48.3 6
L415 3360 36000 58.4 4
R415 3 3 60 36000 50.1 6
L 440 3 3 60 32938 51.3 6
R 440 3 3 60 32938 43.2 6
L 480 3 3 60 39198 54.8 6
R 480 3 3 60 39198 47.1 6
TMKEL-60-T, TMKEL-80-T, TMKEL-100-T
Kettle
(Left/Right)
Supply
Voltage
Phase
Wires
HZ
Total
Wattage
Supply
Amps
Wire Size
C
W
(I.D.)
H
(TRUNNION)
G
D
K
X
26.50"
673mm
2" (51mm) TANGENT
DRAW OFF VALVE
KETTLE
LIP IN
TILTED
POSITION
6.50" (165mm)
21.00"
533mm
3.00"
76mm
8.75"
222mm
E
F
Y
COVER
FULLY
OPEN
7.25"
184mm
3.25"
83mm
H C
H C
SEE
RECOMMENDED
FLOOR SLOPE
M
N
A
+ 0.125 (3.18mm), - 0
18"
475mm
10"
254mm 5.75"
146mm
5.75"
146mm
L
REAR OF CONSOLE
O
SEE FLANGED
FOOT DETAIL
FLOOR
DRAIN
GRATES
R
P
5" (127mm)
Q Q
13"
330mm
5.00"
127mm
S
T
U
(DRAIN
GRATE)
V
(DRAIN
GRATE)
0.56"
14mm
120º
TYP
1.00" (25mm)
MAX. ADJUSTMENT
1.625" (42mm)
Ø
FLANGED FOOT DETAIL
0.44" (11mm)
Ø
3 HOLES ON
3.125" (80MM)
Ø
B.C.D.
4 7/8"
124
Ø
mm
FLOOR SLOPE = 1.00" (26mm) per 4' (1220mm)
RECOMMENDED FLOOR SLOPE
PIPE DRAIN RECOMMENDED
min. valve size plus 1.00" (26mm)
6.00" (153mm) RECOMMENDED
4.00" (102mm) MINIMUM
40/150 99.00
2511
26.00
660
43.25
1099
52.75
1340
72.00
1829
10.25
260
23.13
587
55.75
1416
11.00
279
27.38
695
39.88
1013
36.00
915
18.38
467
28.00
711
38.00
965
5.63
143
27.00
686
30.00
762
44.00
1118
18.25
464
76.00
1930
GAL/LIT A C D E F G H J K ML N0PQRST UVW X Y
60/225 106.00
2689
29.50
750
43.25
1099
52.75
1340
73.00
1854
10.25
260
23.13
587
57.50
1460
6.63
168
27.38
695
42.13
1070
36.00
915
18.38
467
28.00
711
41.50
1054
6.50
165
9.50
749
31.00
787
45.00
1143
14.75
375
79.00
2007
80/300 113.00
2867
33.00
838
45.75
1162
55.25
1403
79.00
2007
12.75
324
26.38
670
59.00
1500
6.63
168
32.63
778
46.38
1178
39.25
997
21.63
549
31.25
794
45.00
1143
7.38
187
31.38
797
35.00
889
46.00
1168
15.00
381
84.00
2134
100/375 35.50
902
47.75
1213
57.25
1454
82.00
2083
14.75
375
26.38
670
61.00
1550
6.00
152
32.63
778
47.63
1210
39.25
997
21.63
549
31.25
794
47.50
1207
8.00
203
33.00
838
36.00
914
47.00
1194
15.00
381
54.38
1381
30.50
775
58.50
1486
34.00
864
63.00
1600
37.50
953
66.00
1676
40.00
1016
89.00
2261
117.88
2994
DIMENSIONS ("/mm)
3.00"
76mm
18" (457mm)
Recomended
0 = Minimum
Z
A2
A1
16.00
406
Z
18.25
464
19.13
486
20.75
527
35.75
980
A1
37.50
953
42.75
1086
43.75
1111
39.00
991
A2
40.75
1035
46.00
1168
47.00
1194
4" NPT
C NPT
C " NPT
NPT
ELECTRICAL - HIGH WATTAGE
WATER
Hot Water 3/4 NPT
Cold Water 3/4 NPT
H
C
Right - 0, Left - 0
Rear -
18" (457mm)
Recommended
0-Minimum
CLEARANCE

This manual suits for next models

3

Other Cleveland Kettle manuals

Cleveland KGT-6-T User manual

Cleveland

Cleveland KGT-6-T User manual

Cleveland HA-MKDL-100-CC User manual

Cleveland

Cleveland HA-MKDL-100-CC User manual

Cleveland MKET-20-T User manual

Cleveland

Cleveland MKET-20-T User manual

Cleveland MKGL-40-T User manual

Cleveland

Cleveland MKGL-40-T User manual

Cleveland 18-DM-K6 User manual

Cleveland

Cleveland 18-DM-K6 User manual

Cleveland MKDT-20-T User manual

Cleveland

Cleveland MKDT-20-T User manual

Cleveland KET-12-T User manual

Cleveland

Cleveland KET-12-T User manual

Cleveland KEL-100-T User manual

Cleveland

Cleveland KEL-100-T User manual

Cleveland MKDL-100-CC User manual

Cleveland

Cleveland MKDL-100-CC User manual

Cleveland KEL-40-TSH User manual

Cleveland

Cleveland KEL-40-TSH User manual

Cleveland KDT-1 -T Manual

Cleveland

Cleveland KDT-1 -T Manual

Cleveland HA-MKDL-100-CC-T User manual

Cleveland

Cleveland HA-MKDL-100-CC-T User manual

Cleveland KDT-1-T User manual

Cleveland

Cleveland KDT-1-T User manual

Cleveland MKDL-100-T User manual

Cleveland

Cleveland MKDL-100-T User manual

Cleveland KDL-SH User manual

Cleveland

Cleveland KDL-SH User manual

Cleveland KDL-25-T User manual

Cleveland

Cleveland KDL-25-T User manual

Cleveland KEL-25-T User manual

Cleveland

Cleveland KEL-25-T User manual

Cleveland SSE-25-L Operating instructions

Cleveland

Cleveland SSE-25-L Operating instructions

Cleveland HA-MKGL-100-TCC User manual

Cleveland

Cleveland HA-MKGL-100-TCC User manual

Cleveland TMKDL-100-T User manual

Cleveland

Cleveland TMKDL-100-T User manual

Cleveland KGL User manual

Cleveland

Cleveland KGL User manual

Cleveland KDL-40-SH User manual

Cleveland

Cleveland KDL-40-SH User manual

Cleveland KEL-100 User manual

Cleveland

Cleveland KEL-100 User manual

Cleveland 36-GM-K1010-200 User manual

Cleveland

Cleveland 36-GM-K1010-200 User manual

Popular Kettle manuals by other brands

Metos VIKING Installation and operation manual

Metos

Metos VIKING Installation and operation manual

Superior 10002104 Instructions for use

Superior

Superior 10002104 Instructions for use

Scarlett SC-EK18P33 instruction manual

Scarlett

Scarlett SC-EK18P33 instruction manual

Caso VAKO2 manual

Caso

Caso VAKO2 manual

Lumme LU-140 user manual

Lumme

Lumme LU-140 user manual

Gallet BOU 801WB instruction manual

Gallet

Gallet BOU 801WB instruction manual

Kenwood ZJM810BK instructions

Kenwood

Kenwood ZJM810BK instructions

gourma GK320 manual

gourma

gourma GK320 manual

Kenwood SJM030 series instructions

Kenwood

Kenwood SJM030 series instructions

Brandt BO1800T Series instruction manual

Brandt

Brandt BO1800T Series instruction manual

Vitek VT-1162 Manual instruction

Vitek

Vitek VT-1162 Manual instruction

TEFAL KO3718 manual

TEFAL

TEFAL KO3718 manual

Russell Hobbs 24990-70 manual

Russell Hobbs

Russell Hobbs 24990-70 manual

Concept2 RK 2110 instruction manual

Concept2

Concept2 RK 2110 instruction manual

Concept2 RK2150 operating manual

Concept2

Concept2 RK2150 operating manual

Silvercrest SWC 2400 A1 operating instructions

Silvercrest

Silvercrest SWC 2400 A1 operating instructions

German pool KTT-309 user manual

German pool

German pool KTT-309 user manual

Morphy Richards Aspects manual

Morphy Richards

Morphy Richards Aspects manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.