Cremesso SMART BRAVA User manual

USER MANUAL
R
E
A
D
Y
T
O
U
S
E
I
N
15
SEC.
BRAVA
SMART LINE

Delica AG, Bresteneggstrasse 4, 5033 Buchs, SWITZERLAND
2
Contents
Safety instructions ....................................................3
Overview ......................................................................8
Key functions ..............................................................8
Key illumination.........................................................9
Starting up...................................................................9
Flush out piping...................................................... 10
Coee preparation................................................. 10
Preinfusion function.............................................. 11
Eject capsule ............................................................ 11
Low water indicator............................................... 12
Programming the coee quantity.................... 12
Programming reset ............................................... 12
Energy-saving mode ............................................. 13
Descaling................................................................... 13
11 / 22 / 1052
Cleaning the machine .......................................... 15
Transport / storage ............................................... 16
Disposal ..................................................................... 16
Technical data.......................................................... 17
Troubleshooting ..................................................... 18

3
Safety instructions
General information
This manual is an integral part of your product.
XPlease read this manual thoroughly before
erection, installation and commissioning the
machine, and keep it for future reference.
XAlways hand this manual over to future owners
or users of the product.
The manufacturer cannot be held responsible for
damage or defects caused by disregarding this
instruction manual.
XOnly operate the machine with the appropriate
capsules.
Intended use
This machine may be used only as described in
this manual. Using it for other purposes is abusive
and dangerous.
This machine is intended for domestic use and in
other similar areas, such as:
• in kitchens for use by employees
• in oces and other commercial areas
• in agricultural holdings
• in hotels, motels, boarding houses and similar
residential type environments
The machine is not suitable for commercial use.
The machine is not designed for use outdoors.
The machine must not be used in a non-station-
ary location (e.g. on ships, in vehicles, in trains,
etc.).
The manufacturer assumes no liability for conse-
quences resulting from improper use.
Requirements on the location
XUse the machine only in dry rooms.
XDo not use the machine inside a cupboard.
XMaintain a distance of 60 cm from the sink
and 50 cm from an open ame (a mains water
connection is not permitted).
XEnsure the machine and its power cable are not
located next to hobs, gas cookers, naked ames
or similar hot surfaces.
XNever place the machine on a hot surface.

4
XPlace the machine on a dry, horizontal, stable
and at surface. The surface must be resistant to
heat and liquids such as water, coee, descaling
uid or the like.
XDo not place on marble surfaces or untreated /
oiled woodwork (no liability in the event of non-
removable coee of descaler stains).
Requirements for the target group
This machine can be used by children aged 8
years and above under supervision, if they have
been given instruction concerning use of the ap-
pliance in a safe way and understand the hazards
involved.
Cleaning and maintenance must not be carried
out by children unless they are 8 years or older
and are supervised.
The machine and its power cable must not be
accessible to children under 8 years old.
Persons with limited physical, sensory or mental
abilities, or lack of experience and knowledge,
must be supervised or given instruction concern-
ing use of the appliance in a safe way. They must
have understood the dangers associated with its
use.
Children must not play with the machine. The
machine must be kept out of reach of children.
Requirements for the user
XDo not move the machine whilst it is in
operation.
XNever operate the machine without water in the
tank.
XFill the water tank with fresh, cold water only.
Do not use mineral water or carbonated water
in the machine.
XDisconnect the plug from the power socket and
empty the water tank if the machine is not to be
used for a long period.
XKeep packaging materials (plastic bags, lm,
cardboard boxes, etc.) away from children.
XBefore setting up the machine, check it for any
visible damage. Never put a damaged machine
into use.
XBefore connecting the machine to the mains
supply, make sure that the rating on the data

5
plate corresponds to the voltage and frequency
of the household supply. These data must
correspond in order to avoid the risk of damage
to the machine. Consult a qualied electrician if
in any doubt.
XThe electrical safety of this machine can be
guaranteed only when it is correctly earthed.
If in any doubt, have the electrical installation
tested by a qualied electrician.
XDo not connect the machine to the mains
electricity supply by an extension lead or
multiple socket.
XUse the machine only at ambient temperatures
between +16°C and +38°C.
XOnly use genuine original accessories and
spare parts. Using accessories or spare parts
from other manufacturers will invalidate the
guarantee and product warranty liability.
Requirements for cleaning
XWithdraw the power plug and allow the
machine to cool down completely before
re-positioning it, cleaning it or carrying out
maintenance work.
XNever immerse the machine completely or
partially in water or any other liquid.
XNever hold the machine under running water.
XUse only clean cleaning materials to clean the
machine.
XDo not use strong cleaning detergents or
solvents.
XUse a soft, damp cloth to clean the surface of
the machine.
XOnly use cleaning and descaling agents
recommended by the manufacturer. Avoid
contact with eyes, skin and other surfaces.

6
Residual risks
Risk of injury from electric shock
XEnsure that the power supply cable is not
pinched and does not rub against sharp edges.
XNever touch the power plug with wet hands.
XIf you want to pull the plug from the power
outlet, always pull directly on the plug. Never
pull on the cable.
XDamaged power cables must be replaced
immediately and only by the customer service
centre.
Risk of injury from sharp edges and crushing
XClose the lever before operating. Never open
the lever when the machine is in operation
(dispensing coee, descaling).
XDo not put your nger into the capsule
compartment or capsule chute. Parts of the
machine can be pointed and sharp.
XWhen closing the operating lever, do not reach
underneath it.
XDo not insert ngers or objects into the
openings of the machine.
Risk of injury from scalding
Machineparts and capsules can become very hot
during and after operation. Risk of burning and
scalding at the outlets. The emerging liquids and
the steam are very hot.
XDo not touch.
XDo not operate the operating lever until the
dispensing or descaling process is completely
nished.
Risk of injury from stumbling
XMake sure that the power cable does not hang.
Risk of injury by touching live parts
XDo the not open the housing of the machine.
XDo not alter the electrical and mechanical
design.
Risk of injury due to damage to the machine
XDo not use the machine after it has been
dropped, if it is exhibiting a malfunction, has
a damaged power cable or is damaged in any
other way.

7
XPull out the power plug immediately if
malfunctions, damage or anomalies (e.g. smell
of burning) occur.
XIn the event of a malfunction, have the machine
checked by the customer service centre.
Risk of damage to the machine due to
overheating
XEnsure there is adequate ventilation and
exhaust extraction from the machine. Do not
cover the machine with cloths or similar whilst it
is in operation.

Overview
1 Operating lever for loading
capsules
2 Operating keys functions
(PAGE8)
3 Output
2
3
1
4 Capsule container, removable
5 Drainage tank
6 Cup tray, fold-out
7 Drip tray with drain grill,
removable
5
6
7
4
8 Water tank cover, removable
9 Water tank 1.3 litres
10 Power cable with cable winder
9
10
8
Key functions
Cleaning key
Flushes out piping.
Coee keys
Espresso key
Medium cup (50 ml)
Lungo key
Large cup (110 ml)
LungoGrande key
Very large cup (200 ml)
8

Key illumination
All keys
Light up: Coee machine is ready
for use.
Coee key
Lights up: Brewing.
Flashing: Warm-up, programming of
coee quantity in progress.
Lungo Grande key and cleaning
key ash: Steaming out in
progress.
Cleaning key
Lights up blue: Lack of water.
Flashes red during preparation:
Descale the machine.
Lights up red: Electronic or
temperature error.
Flashes purple: Descaling in
progress.
Lights up purple: Indicates water
tank change during descaling.
Flashes purple/red: Descaling
stopped due to power interruption.
Flush machine.
Starting up
XPlace the
coee machine on a dry
surface that is waterproof and
heat-proof.
XDo not place the coee machine
directly on marble or wood (risk
of coee or descaler stains).
XMaintain a distance of 60 cm from
the sink and 50
cm from an open
ame.
50 cm
60 cm
XClean the water tank and ll with
cold water.
XInsert power plug in an earthed
socket.
The cleaning key ickers.
XPress any key.
Flush out piping at least 5 times
(PAGE10).
If the temperature of the coee machine is below 5°C or very high, the
machine cannot be started and all keys ash.
Temperature of coee machine below 5°C:
XAllow the coee machine to warm up for 30 minutes at room
temperature.
Temperature of coee machine very high:
XAllow the coee machine to cool down.
9

Flush out piping
XPlace a cup under the output.
XPress the cleaning key .
The ushing process starts.
50ml of water is used per ushing
cycle.
On completion of the ushing
process the machine will switch to
ready mode.
XWhen starting up for the rst
time, repeat this process.
XTo end the ushing process
prematurely, press the cleaning
key again.
If the ushing process does not start:
XRemove the water tank and re-insert.
XPress the cleaning key .
Coee preparation
One capsule is required for each cup
of coee.
XAfter long pauses, ush out the
piping.
Depending on the size of the cup,
adjust the cup tray:
XFold the cup tray forward.
XPlace a cup under the output.
Tips:
• Crema – The closer the cup is to
the outlet, the better the crema.
• Preheat the cup – Press the
espresso key (without capsule)
and ll the cup with water.
Load capsule
XPush the operating lever upwards.
XDrop the capsule into the
opening.
XPush the operating lever
downwards.
The capsule is pierced.
2.
1.
Coee output
XPress the coee key:
Espresso: medium cup (50 ml)
Lungo: large cup (110 ml)
Lungo grande: very large cup
(200 ml)
10

Preinfusion function
The preinfusion function gives your
coee more aroma.
For coee quantities up to 80 ml, a
small amount of coee is dispensed
rst.
The preinfusion function starts and
the output stops for 3seconds.
The output then continues.
Output stops automatically or press
the key again to stop earlier.
3
sec
The preinfusion function depends on the output quantity and is not
associated with the individual keys.
When the keys (PAGE12) are programmed, the preinfusion function
remains unchanged for output quantities up to 80ml. For output
quantities over 80ml, the preinfusion function is not carried out.
Eject capsule
Tip: To prevent drips from the outlet
– eject the capsule after the coee
output.
XPush the operating lever upwards.
The used capsule drops into the
capsule container.
XPull operating lever down.
1.
2.
Forgotten capsules may stick in
the opening.
Caution! Risk of injury due to sharp
opening point inside the machine!
XPush capsule down carefully.
11

Low water indicator
The water tank is equipped with a
low water indicator.
If the water tank is empty, the
cleaning key lights up blue.
Programming the coee quantity
The output quantities can be
adjusted for each coee key.
The default settings are:
Espresso: 50ml
Lungo: 110ml
Lungo Grande: 200ml
The programmable output quantity
is 30–250ml.
XPlace a cup under the output.
XCheck the level of the water tank.
Fill with water, if required.
XLoad capsule.
XHold down the key to be
programmed (e.g. Espresso
) for at least 3 seconds, until it
ashes rapidly three times.
XRelease the key.
Coee output starts.
XWhen your cup is full enough:
Press the key to be programmed
(e.g. espresso ) again.
Coee output stops.
All keys light up.
The new programmable quantity
setting is applied.
If the water tank empties during
programming:
XRepeat the programming with a
full water tank.
Programming reset
XPull out the power plug.
XHold down the cleaning key
and re-insert power plug.
XRelease the key.
Cleaning key ashes rapidly three
times. The default settings are
restored.
12

Energy-saving mode
When the coee machine is not
used for 1minute or the cleaning
key is pressed for 3seconds, the
coee machine switches to energy-
saving mode.
The key illumination goes out.
XTo exit energy-saving mode, press
any key.
1
min
Cleaning for the best coee quality
When preparing coee, deposits of
water as well as coee oils and fats
are left behind in the piping of the
coee machine.
These residues have a negative
eect on the coee taste.
Regular descaling of the machine
can remove these residues.
Coee machines which are calcied
invalidates the warranty.
Descaling
After 40l of drinks, the cleaning key
ashes red during dispensing.
XDescale the machine thoroughly.
Attention! Only use descalers for
coee machines. Never use vinegar.
XUse descaler (min. 0.5l) according
to manufacturer’s instructions
and ll the water tank.
13

XRemove all capsules from the
coee machine.
XPull the lower drip tray upwards
and remove.
XPlace a large bowl (min. 1.2 litres)
under the output.
XPress the cleaning key and
the LungoGrande key
simultaneously.
The cleaning key ashes purple,
the descaling process starts.
This process takes approximately 25
minutes.
25
min
XIf the cleaning key lights up
purple, rinse water tank, ll with
water and replace.
XEmpty the descaler uid bowl and
place it under the output.
XPress the cleaning key .
The ushing process starts and the
cleaning key ashes purple.
If the water tank is empty, after 3
minutes the cleaning key lights
up blue.
3
min
XFill water tank and insert.
The machine is now ready for use.
If power is interrupted during
descaling, the cleaning key ashes
purple/red.
XFlush the lines with 300ml
(PAGE10).
Attention! Interrupt the descaling
process only if there is no descaling
uid in the water tank.
XTo interrupt the descaling
process, press the cleaning
key and Lungo Grande key
simultaneously.
14

Cleaning the machine
Caution! Always pull out the power
plug rst before cleaning!
Attention! Never immerse the
coee machine in water!
Never wash under running water!
XClean the coee machine and
output with a damp cloth.
Never rub dry or use abrasive
detergents.
Empty the drip tray, capsule
container and water tank daily
The capsule container holds approx.
10-12 capsules and the drainage
tank approx. 150 ml residual
water (equivalent to approx. 12
beverages).
XLift the drainage tank with
capsule container slightly and
pull it forward.
XPull the drip tray forward, remove
the drain grille and clean both.
XPull capsule container upward.
XEmpty the capsule container and
clean.
XEmpty the drainage tank and
clean it.
XRe-insert the capsule container,
drainage tank, drip tray and
the drain grille into the coee
machine in reverse order.
XEmpty the water tank and clean it.
The capsule container can be washed in the dishwasher.
The remaining machine components are not dishwasher safe!
15

Transport / storage
During transport and storage, no
water must be present in the coee
machine.
XPull out the power plug.
XEmpty the water tank and replace
it.
XPlace a cup under the output.
XHold down the Lungo Grande key
and re-insert the power plug.
XRelease the Lungo Grande key
after approx. 2 seconds.
The pump starts and the cleaning
key and the Lungo Grande key
ash. The residual water is pumped
out of the coee machine.
As soon as the pump stops, the key
lights extinguish and emptying out
is nished.
2.
1.
XPull out the power plug.
XAllow the coee machine to cool
down.
XStore the coee machine in
the original packaging in a dry,
dust-free place, out of reach of
children.
XFlush out the machine and piping
before using again.
Disposal
XDispose of used capsules and
worn-out machines according to
the regulations in your country.
X
XMachines can be returned to your
dealer for professional disposal
free of charge.
XThe option to return machines
for free is not limited to new
purchases.
XImmediately take machines with
dangerous defects to the service
centre or dispose of them and
ensure that they can no longer
be used.
XDo not dispose of machines with
household waste (environmental
protection!).
1.
2.
16

Technical data
Parameter Value
Rated voltage 230 V, 50 Hz
Rated power 1450W
Energy-saving mode 0.3W
Dimensions (mm)
(W×H×D)
130×252×353
Weight 2.75 kg
Water tank capacity 1.3 litres
17

18
Troubleshooting Remedial action
Coee output is interrupted The preinfusion function interrupts
the coee output (PAGE11)
Occasional drips from the outlet Used capsule in machine.
XEject capsule (PAGE11).
Water drips continuously from the
outlet
Machine calcied.
XDescale the machine
(PAGE13).
Not working Power plug not inserted.
XInsert power plug.
Keys blocked.
XPull out power plug and reinsert
after 10 seconds.
Troubleshooting Remedial action
Capsule remains in opening XEject capsule(PAGE11).
Pump sounds very loud Water tank empty.
XFill water tank and insert.
Cup lling not as programmed Programming changed.
XRepeat programming
(PAGE12).
Programmed cup lling is no
longer correct
Water tank empty.
XFill water tank and insert.
Machine calcied.
XDescale the machine
(PAGE13).
Troubleshooting
If this troubleshooting guide does not help you solve your problem, please
contact your nearest service centre.
The machine may be repaired only by an authorised service centre.
No liability will be accepted for any damage due to unprofessional repairs
and use of non-original spare parts, which may endanger the user and will
render the guarantee null and void.
Caution! Immediately disconnect the power supply to a machine that is
faulty or defective, or if you suspect damage after it has been dropped.

19
Troubleshooting Remedial action
Coee tastes sour Inadequate ushing after descaling.
XFlush out piping (PAGE10).
No water sucked in after tank was
empty
Used capsule in machine.
XEject capsule (PAGE13).
XFlush out piping (PAGE10).
XTry again without capsule after
30 minutes.
XIf water is sucked in: Descale the
machine (PAGE13).
XIf still no water sucked: contact
service centre.
Long Espresso output time The preinfusion function extends
the coee output time for full
aroma.
All keys ash XWait 30 minutes.
If the problem persists:
XContact service centre.
Troubleshooting Remedial action
No coee output, or insucient
output
Water tank empty.
XFill water tank and insert.
Defective capsule.
XInsert a new one.
XClose operating lever as far as
the stop.
Operating level not fully closed.
XClose operating lever as far as
the stop.
Machine calcied.
XDescale the machine
(PAGE13).
Use water from softening device
(increased processing time).
XMonitor/adjust softening device
or use water before it passes
through the device.
Pump defective.
XContact service centre.

1 2 3
4 6
7 8
Lungo Grande:
200 ml
Espresso: 50ml
Lungo: 110 ml
1.
2.
5
AB
www.cremesso.com
Quickstart Guide
Table of contents
Other Cremesso Coffee Maker manuals

Cremesso
Cremesso UNA Automatic User manual

Cremesso
Cremesso Coffee Machine Installation instructions

Cremesso
Cremesso COMPACT PRO User manual

Cremesso
Cremesso VIVA User manual

Cremesso
Cremesso compact one User manual

Cremesso
Cremesso CAFFE Latte User manual

Cremesso
Cremesso PROFESSIONAL COMPACT PRO User manual

Cremesso
Cremesso compact Automatic User manual

Cremesso
Cremesso UNO User manual

Cremesso
Cremesso compact Automatic User manual