CLC-FANDELVEX-W
inNET EX®Fan Controller
Installation Guide
Description
The Crestron®CLC-FANDELVEX-W is an inNET EX fan and light controller. The compact
design allows it to securely t in a fan canopy.
Refer to the following table for specications for the CLC-FANDELVEX-W.
Installation
WARNING: To avoid re, shock, or death, turn off the power at the circuit breaker or
fuse and test that the power is off before wiring!
WARNING: To reduce the risk of electric shock, install the CLC-FANDELVEX-W with an
isolating wall control or switch.
CAUTION: To reduce the risk of overheating and possible damage to other equipment,
do not install to control a receptacle.
NOTES: Observe the following points:
• Install and use this prodct in accordance with appropriate electrical codes and
regulations.
• A licensed electrician should install this product.
• Do not install in a damp or moist environment. This product is for indoor use only.
NOTE: Before using the CLC-FANDELVEX-W, ensure the device is using the latest
rmware. Check for the latest rmware for the CLC-FANDELVEX-W at
www.crestron.com/rmware. Firmware is loaded onto the device using Crestron
Toolbox™ software.
NOTE: Refer to the documentation for the fan for proper installation or disassembly and
reassembly.
NOTE: Using the fan’s hardware controls, set the fan to high speed and the lights to on.
NOTE: Remove any pre-installed fan remote controller before installing the
CLC-FANDELVEX.
Install the CLC-FANDELVEX-W after all connections have been made. The
CLC-FANDELVEX-W can be inserted into most common fan canopies. Refer to the
following illustration for details.
Additional Resources
Visit the product page on the Crestron website (www.crestron.com)
for additional information and the latest rmware updates. Use a QR
reader application on your mobile device to scan the QR image.
To Junction Box
CLC-FANDELVEX-W
Ceiling Fan
Mounting
Bracket
To Junction Box
CLC-FANDELVEX-W Installed in Fan Canopy
The CLC-FANDELVEX-W has a multifunction ACQUIRE button and STATUS, LIGHT, and
FAN LEDs. Their functions are described below.
The ACQUIRE button:
• Allows the device to connect to the inNET EX network. Refer to the “Wireless
Communications” section for details.
• Press to toggle the dimming load between on and off.
• Press to exit Identify mode.
The STATUS LED:
• Illuminates green to indicate it is receiving power.
• Flashes green to indicate inNET EX acquire status.
• Flashes red to indicate error conditions.
NOTE: The green LED extinguishes after 1 minute. The red LED extinguishes
when the error is cleared.
The LIGHT LED:
• Illuminates to indicate that a command was received to turn on the light.
NOTE: The LIGHT LED extinguishes after 1 minute.
The FAN LED:
• Illuminates to indicate that a command was received to turn on the fan.
NOTE: The FAN LED extinguishes after 1 minute.
SPECIFICATION DETAILS
Current Ratings
Fan Load 120 Vac, 0.8 A, 60 Hz
Light Load 120 Vac, 200 W, 60 Hz
(100 W Max for CFL or LED Loads)
Load Types Dimmed incandescent, CFL, LED, tungsten,
electronic low voltage
NOTE: Do not connect to magnetic low-voltage
type loads.
Environmental
Temperature 32° to 104 °F (0° to 40 °C)
Humidity 10% to 90% RH (noncondensing)
Wiring
The module has ying leads for power and control. Power enters the CLC-FANDELVEX-W
and passes fan control and light power to the fan. The CLC-FANDELVEX-W has one black
(hot) and one white (neutral) power input. It also has a red (fan), blue (light), and white
(neutral) output for control.
NOTE: Refer to the documentation for the fan to ensure proper fan wiring.
Wiring the CLC-FANDELVEX-W
Power and
Control
Output
Power
Input
AC 110 V 60 Hz
Wall Switch
White
Black
White (Neutral)
Black (Hot)
Red (Fan Power)
Blue (Light Power)
Blue Black (Motor)
White
White
(Neutral)
Regulatory Compliance
This product is Listed to applicable UL®Standards and requirements by Underwriters Laboratories
Inc.
Conformité Reglementaire
Ce produit est homologué selon les normes et les exigences UL applicables par Underwriters
Laboratories Inc.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
CAUTION: Changes or modications not expressly approved by the manufacturer responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Wireless Communications
The device connects to the Crestron network via the inNET EX communications protocol.
Use the procedures outlined below to join or leave an inNET EX network and to verify
communications between the device and the control system.
Joining an inNET EX Network
Before a device can be used in a lighting system, it must rst join an inNET EX network.
To join an inNET EX network, the device must be acquired by an inNET EX gateway.
NOTE: A device can be acquired by only one gateway.
1. Put the inNET EX gateway into Acquire mode from the unit itself or from Crestron
Toolbox. Refer to the gateway’s manual at www.crestron.com/manuals for details.
NOTE: In an environment where multiple gateways are installed, only one
gateway should be in Acquire mode at any time.
2. Put the device into Acquire mode.
a. Tap the ACQUIRE button three times and then press and hold it down
(tap-tap-tap-press+hold) until the green STATUS LED on the device blinks once
(this can take up to 10 seconds).
b. Release the button to start the acquire process. The green STATUS LED blinks
slowly to show that the device is actively scanning the inNET EX network.
• The green STATUS LED turns on for 5 seconds to show that the device has
been successfully acquired by the infiNET EX network.
• The green STATUS LED blinks fast to indicate that the device was not
successfully acquired by the infiNET EX network. Tap the ACQUIRE button to
acknowledge the failure. Ensure the gateway is in Acquire mode and within
range before attempting the acquire process again.
3. Once all devices have been acquired, take the gateway out of Acquire mode. Refer
to the gateway’s manual for details.
Leaving an inNET EX Network
To leave an inNET EX network, put the device into Acquire mode, as described in
“Joining an inNET EX Network” above, when no gateway is in Acquire mode.
Verifying Communications Status
To check the communications status of the device, tap the ACQUIRE button three times
and then press and hold it down (tap-tap-tap-press+hold) for up to 2 seconds. The green
STATUS LED blinks to indicate the communications status. Refer to the following table for
details.
Crestron Electronics, Inc. Installation Guide - DOC. 7705B
15 Volvo Drive Rockleigh, NJ 07647 (2045179)
Tel: 888.CRESTRON 06.16
Fax: 201.767.7576 Specications subject to
www.crestron.com change without notice.
Industry Canada (IC) Compliance Statement
CAN ICES-3(B)/NMB-3(B)
The product warranty can be found at www.crestron.com/warranty.
The specic patents that cover Crestron products are listed at patents.crestron.com.
Certain Crestron products contain open source software. For specic information, please visit
www.crestron.com/opensource.
Crestron, the Crestron logo, Crestron Toolbox, inNET EX, and the inNET EX logo are either
trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other
countries. UL and the UL logo are either trademarks or registered trademarks of Underwriters
Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered
trademarks, and trade names may be used in this document to refer to either the entities claiming the
marks and names or their products. Crestron disclaims any proprietary interest in the marks and
names of others. Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2016 Crestron Electronics, Inc.
MODULE WIRE CONNECTION
White Neutral wires to
the junction box
and fan
Black Connects to the
live wire.
Red Connects to the
fan motor wire.
Blue Connects to the
lights.
Error States
The LED blinks a pattern to indicate an error. The patterns listed below are described as
2-1 or 2-3. For a 2-1 error, an overcurrent condition, the LED blinks twice, pauses for 1
second, blinks once, pauses for two seconds, and then repeats until the error is
corrected. During an overcurrent condition, the lights will turn off. Sending a new light
level corrects the overcurrent condition.
For a 2-3 error, an overtemperature error, the LED blinks twice, pauses for 1 second,
blinks three times, pauses for two seconds, and then repeats until the error is corrected.
During an overtemperature condition, the light and fan will turn off. During an
overtemperature error, requests to turn on the load or fan are ignored. The error clears
when the device cools.
NOTE: The overtemperature error is not saved in nonvolatile memory and is cleared
when power is cycled.
FAN WIRE TYPICAL COLOR
Fan Black
Lights Blue
Neutral White
LED COMMUNICATIONS STATUS
Turns on for 5 seconds The device is communicating with the control system.
Blinks three times The device is communicating with the gateway, but the
gateway is not communicating with the control system.
Blinks twice The device was previously joined to the network but is
not communicating with the gateway.
Blinks once The device is not joined to the network.

Other Crestron Controllers manuals

Crestron 4 Series User manual

Crestron

Crestron 4 Series User manual

Crestron DM-RMC-SCALER-S How to use

Crestron

Crestron DM-RMC-SCALER-S How to use

Crestron CH-HREL8-D6 User manual

Crestron

Crestron CH-HREL8-D6 User manual

Crestron MC2W User manual

Crestron

Crestron MC2W User manual

Crestron 302 User manual

Crestron

Crestron 302 User manual

Crestron INET-IOEX-IRCOM User manual

Crestron

Crestron INET-IOEX-IRCOM User manual

Crestron C3COM-3 User manual

Crestron

Crestron C3COM-3 User manual

Crestron C2N-SDC-DC How to use

Crestron

Crestron C2N-SDC-DC How to use

Crestron DigitalMedia 8G+ DM-RMC-200-C Dimensional drawing

Crestron

Crestron DigitalMedia 8G+ DM-RMC-200-C Dimensional drawing

Crestron ST-VC User manual

Crestron

Crestron ST-VC User manual

Crestron CN-TVAV User manual

Crestron

Crestron CN-TVAV User manual

Crestron PC-350V-12 User manual

Crestron

Crestron PC-350V-12 User manual

Crestron DM-RMC-4K-SCALER-C User manual

Crestron

Crestron DM-RMC-4K-SCALER-C User manual

Crestron DM-RMC-4K-100-C-1G User manual

Crestron

Crestron DM-RMC-4K-100-C-1G User manual

Crestron CP3-R User manual

Crestron

Crestron CP3-R User manual

Crestron MC2E User manual

Crestron

Crestron MC2E User manual

Crestron 3 Series User manual

Crestron

Crestron 3 Series User manual

Crestron PC-200 Owner's manual

Crestron

Crestron PC-200 Owner's manual

Crestron CNXFZ User manual

Crestron

Crestron CNXFZ User manual

Crestron 4K DigitalMedia 3-Series Dimensional drawing

Crestron

Crestron 4K DigitalMedia 3-Series Dimensional drawing

Crestron ZUMMESH-JBOX Series User manual

Crestron

Crestron ZUMMESH-JBOX Series User manual

Crestron 3 Series Dimensional drawing

Crestron

Crestron 3 Series Dimensional drawing

Crestron CNECI-4A User manual

Crestron

Crestron CNECI-4A User manual

Crestron CLS-EXP-DIMFLV User manual

Crestron

Crestron CLS-EXP-DIMFLV User manual

Popular Controllers manuals by other brands

DSE DSE4510 Operator's manual

DSE

DSE DSE4510 Operator's manual

GE b30 instruction manual

GE

GE b30 instruction manual

Omron CS1G/H-CPUxx-EV1 Programming manual

Omron

Omron CS1G/H-CPUxx-EV1 Programming manual

Azbil Micro Flow MQV9020 user manual

Azbil

Azbil Micro Flow MQV9020 user manual

ATI Technologies IOM1030 Installation, operation & maintenance manual

ATI Technologies

ATI Technologies IOM1030 Installation, operation & maintenance manual

Celec ES-30 Field installation manual

Celec

Celec ES-30 Field installation manual

Onkyo PR-SC5507 instruction manual

Onkyo

Onkyo PR-SC5507 instruction manual

Rain Bird ESP-4Si Installation & operation manual

Rain Bird

Rain Bird ESP-4Si Installation & operation manual

Uhlenbrock IB-COM user manual

Uhlenbrock

Uhlenbrock IB-COM user manual

Transcension SDC6 user manual

Transcension

Transcension SDC6 user manual

Siemens N 567/01 Technical product information

Siemens

Siemens N 567/01 Technical product information

Festo CMMP-AS M0 Series manual

Festo

Festo CMMP-AS M0 Series manual

AKO 15301 manual

AKO

AKO 15301 manual

Ergon RC10 eRocker Installation and user instructions

Ergon

Ergon RC10 eRocker Installation and user instructions

Fiscal VL Odotrack Technical guide

Fiscal VL

Fiscal VL Odotrack Technical guide

Bosch FW 200 Installation and operating instructions

Bosch

Bosch FW 200 Installation and operating instructions

Parker 690+ series product manual

Parker

Parker 690+ series product manual

Belimo LF-2 Series Product information

Belimo

Belimo LF-2 Series Product information

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.