manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DANLERS
  6. •
  7. Switch
  8. •
  9. DANLERS CZ CEFL Quick start guide

DANLERS CZ CEFL Quick start guide

Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. products
Please call for more information or a free catalogue, or visit our website.
This product conforms to BS EN 60669-2-1, BS EN 55015 and BS EN 60730.
Please ensure the most recent edition of the appropriate local wiring regulations are observed
and suitable protection is provided (protected with the appropriate MCB) 1kV over voltage.
Please ensure that this device is disconnected from the supply if an insulation test is made.
This product is covered by a warranty which extends to 5 years from the date of manufacture.
Precautions and Warranty
08/09/16 INS004 CZ CEFL
Variants
DANLERS design and manufacture other ControlZAPP Ceiling Flush Mounted variants,
coded by the following order codes:
CZ CEFL VF Suitable for mains switching, Volt Free contacts
CZ CEFL 10VDC Suitable for 1-10VDC ballasts
CZ CEFL 10VDCVF Suitable for 1-10VDC ballasts, Volt Free contacts
CZ CEFL DALI Suitable for DALI ballasts
CZ CEFL DALIVF Suitable for DALI ballasts, Volt Free contacts.
Troubleshooting
The load will not switch on:
•TheLUXsettingasspeciedbytheControlZAPPAppissettoolowandis
inhibiting the switch.
• The moving body is not emitting more IR than the background.
(Person wearing insulating clothing in a warm environment)
• Person is too far from the PIR switch, see detection diagram.
• Person is moving unusually slowly (perhaps when testing).
• The control unit battery is not engaged (ON).
Switch RED dip switch next to the telejack connector on the control
unit to the DOWN position.
The load switches on when nobody is present:
• Heater causing infra-red variations in a small cold room.
Resite the CZ CEFL control away from heater.
• Please contact DANLERS for further technical support.
 ControlZAPPCeilingushmountedswitches
CZ CEFL
ControlZAPPceilingushmountedmultifunctionaldevicescanbeushmounted
into suspended and plasterboard ceilings (diagram A).
ControlZAPP devices incorporate a passive infra-red quad sensor to detect
movement of a warm body within their detection zone (diagram B) and a photocell
to monitor the ambient light level.
ALLadjustmentsaremadeviaafreelydownloadableControlZAPPApp
availablefromtheDANLERSwebsite.
If CZ CEFL is set as PIR with LUX input, upon detecting movement, if the ambient
light is dark enough, the ControlZAPP device will turn the load ON. The ambient
thresholdcanbesettobetweenapproximately30luxto1000luxandinnitelux
(photocell inactive) via the ‘Respond to Daylight’ settings on the ControlZAPP App.
If no more movement is detected within a pre-selected time as determined by the
ControlZAPP App, then the ControlZAPP device will turn the load off. This ‘Time
Off Timeout’ or time lag can be set via the ControlZAPP App adjuster between
10sec and 23hrs 59min 59sec.
Loading
CZ CEFL is suitable for mains switching or DALI switching only.
CZ CEFL can switch up to:
• 10 amps (3000W) of resistive loads
• 6amps(1500W)uorescentlamps,highfrequencyorswitchstart,
incandescent or mains halogen lamps (recommended with integral safety fuse)
• 3 amps (750W) of electronic or wire wound transformers.
• 2 amps (500W) of low energy lamps: CFL, LED, 2D etc.
• 1 amp (250W) of fans or most metal halide lamps.
Start-upmodeandDefaultsettings
When the CZ CEFL is powered up, it will take 1 minute for the circuitry to stabilise
(detectionLEDashing)andensuretheoutputisoff,theControlZAPPdevicewill
then enter its Default Operating Mode.
Please Note: When in the Default Operating Mode the CZ CEFL is set up as an
occupancy switch with a 20 minute turn OFF timeout (time lag) and photocell disabled.
Installation procedure
1. Please read these notes carefully before commencing work. In case of doubt
pleaseconsultaqualiedelectrician.Ensurewiresandcablesaresecurelyheld
within the connection terminals.
 IMPORTANT:TheCZCEFLControlUnitclockbatterymustbeengaged(ON)
priortoinstallationbyswitchingtheREDdipswitch(seediagramE)tothe
DOWNposition.
2. POSITIONING: The CZ CEFL switch should be installed to achieve correct
coverage of the area, see diagram B.
If the photocell override facility (enabled via
ControlZAPP app) is required, the switch must be located above an area where
daylightcangivegreaterilluminationthanthearticiallight.Avoidlocatingthis
product where it is exposed to drafty conditions (exposed lobbies, open ceiling
voids or near fans) or near heat sources. To cover large areas PIRs should be
spaced in a 5 metre grid formation.
3. Disconnect the PIR from the circuit before performing insulation testing of the
wiring circuit.
4. Do not connect on a circuit with large inductive loads, as induced spikes may
cause false triggering or damage the PIR.
5. CZ CEFL must be connected to the ControlZAPP Power Supply (CZPS) via the
ControlZAPP communication cable provided, for wiring see diagrams C and D.
NOTE: The use of non ControlZAPP connectors may damage the CZ CEFL or
CZPS and will invalidate the warranty.
Settingsandcalibration
NOTE:ALLsettingsareadjustedbyControlZAPPAppasspeciedinthe
ControlZAPPAppUserGuide (downloadable from the DANLERS website)
including: MODE settings, SCHEDULER settings and photocell settings and
intelligent photocell calibration procedure.
MODE settings include: Detect Movement (enable or disable), Sensitivity, Short
Visit Mode (with timer), Turn ON automatically (Presence detection or Absence
detection), Turn OFF timeout (from10sec to 23hrs 59min 59sec), Respond to
Daylight (enabled or disabled) the calibration process must be run for the intelligent
photocell to work. Delay before ON or Delay before OFF timers, Scene Recall (ON
or OFF).
SCHEDULER settings include:
DAY TYPES(deningtimesforeachofthedifferentModestooccur).
WEEKLY SCHEDULE(deningwhichDayTypesareassignedtodifferentdaysof
the week).
EXCEPTIONS(deningexceptionstotheschedulesuchasholidays).
VIEW ON CALENDAR (overview of what Modes happen on any chosen day.
B:Detectiondiagram
up to 5m
up to 7m
Strong detection zone
i.e. person moving arm
or walking towards PIR Secondary detection
zone i.e. person
walking perpendicular
to PIR
For optimum coverage
recommended
mounting height: 2.4 to 5m
SL
L
L
N
Telejack connector Control Unit
Power Supply
Red dip switch (MUST be
switched DOWN (towards lens)
to engage clock battery ON)
IMPORTANT
E:Connectordiagram
A:Mountingdiagram
CEILING VOID
(At least 78mm deep)
75mm circular hole
cut for PIR switch
L
load
N
100 - 260 VAC
50 / 60 Hz
L
N
SL
L
load
N
100-260 VAC
50 / 60 Hz
L
N
SL
L
N
SL
L
N
SL
Several CZ CEFL wired in parallel
Single CZ CEFL
L
load
N
100 - 260 VAC
50 / 60 Hz
L
N
SL
L
load
N
100-260 VAC
50 / 60 Hz
L
N
SL
L
N
SL
L
N
SL
Several CZ CEFL wired in parallel
Single CZ CEFL
C:Wiringdiagram D:Wiringdiagram

This manual suits for next models

5

Other DANLERS Switch manuals

DANLERS COPIR IP66 User manual

DANLERS

DANLERS COPIR IP66 User manual

DANLERS EZ CESR Quick start guide

DANLERS

DANLERS EZ CESR Quick start guide

DANLERS BMPIR10M Quick start guide

DANLERS

DANLERS BMPIR10M Quick start guide

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS CEFLA PIR DALIP Quick start guide

DANLERS

DANLERS CEFLA PIR DALIP Quick start guide

DANLERS CEFL PIR Quick start guide

DANLERS

DANLERS CEFL PIR Quick start guide

DANLERS CESRA PIR DSIP Quick start guide

DANLERS

DANLERS CESRA PIR DSIP Quick start guide

DANLERS GRTLA MK User manual

DANLERS

DANLERS GRTLA MK User manual

DANLERS CESF PIR Quick start guide

DANLERS

DANLERS CESF PIR Quick start guide

DANLERS GRTL MK Quick start guide

DANLERS

DANLERS GRTL MK Quick start guide

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS BMEXPIR Quick start guide

DANLERS

DANLERS BMEXPIR Quick start guide

DANLERS CESPLL10VDC Quick start guide

DANLERS

DANLERS CESPLL10VDC Quick start guide

DANLERS CESRAPIRSD Quick start guide

DANLERS

DANLERS CESRAPIRSD Quick start guide

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS WACEPIR Quick start guide

DANLERS

DANLERS WACEPIR Quick start guide

DANLERS TLSW HB Quick start guide

DANLERS

DANLERS TLSW HB Quick start guide

DANLERS TWSW Quick start guide

DANLERS

DANLERS TWSW Quick start guide

DANLERS WACE RFS Quick start guide

DANLERS

DANLERS WACE RFS Quick start guide

DANLERS CEPH NO Quick start guide

DANLERS

DANLERS CEPH NO Quick start guide

DANLERS GRTLA MK Quick start guide

DANLERS

DANLERS GRTLA MK Quick start guide

DANLERS DUSW Quick start guide

DANLERS

DANLERS DUSW Quick start guide

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

Popular Switch manuals by other brands

NIXER RS32 manual

NIXER

NIXER RS32 manual

Cisco SLM2005 - Small Business Smart Switch user guide

Cisco

Cisco SLM2005 - Small Business Smart Switch user guide

Belkin F5U302DNGL user manual

Belkin

Belkin F5U302DNGL user manual

G&D DVIMUX4-DL-PS/2 Installation and operation guide

G&D

G&D DVIMUX4-DL-PS/2 Installation and operation guide

Lanpro LP-SGW2404FP installation guide

Lanpro

Lanpro LP-SGW2404FP installation guide

Tecsis EGS08 operating manual

Tecsis

Tecsis EGS08 operating manual

Dell PowerConnect 54 Series user guide

Dell

Dell PowerConnect 54 Series user guide

TRENDnet TEG-S50TXE SHEETS Specifications

TRENDnet

TRENDnet TEG-S50TXE SHEETS Specifications

Briggs & Stratton 71057 installation manual

Briggs & Stratton

Briggs & Stratton 71057 installation manual

Trust START-LINE AGST-8802 user manual

Trust

Trust START-LINE AGST-8802 user manual

CYP CLUX-31N Operation manual

CYP

CYP CLUX-31N Operation manual

Eaton CurrentWatch ECSD Series Instruction leaflet

Eaton

Eaton CurrentWatch ECSD Series Instruction leaflet

Moxa Technologies EDS-516A Series user manual

Moxa Technologies

Moxa Technologies EDS-516A Series user manual

Brocade Communications Systems SilkWorm 2200 Series Reference manual

Brocade Communications Systems

Brocade Communications Systems SilkWorm 2200 Series Reference manual

Goobay MS-506 quick start guide

Goobay

Goobay MS-506 quick start guide

PCB Piezotronics IMI SENSORS EX686B01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS EX686B01 Installation and operating manual

ASE EZ-ON user manual

ASE

ASE EZ-ON user manual

Hydropa DS-1 Series operating manual

Hydropa

Hydropa DS-1 Series operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.