DANLERS CESF PIR IP66 Quick start guide

Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIRoccupancyswitches•Daylightlinkeddimmers•Manualhighfrequencydimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers•Heating,ventilationandair-conditioningcontrols•Bespoke/O.E.M.products
Please call for more information or a free catalogue, or visit our website.
ThisproductconformstoBSEN60669-2-1.
Pleaseensurethemostrecenteditionoftheappropriatelocalwiringregulationsareobserved
andsuitableprotectionisprovidede.g.6ampsovercurrent,1kVovervoltage.Pleaseensure
thatthisdeviceisdisconnectedfromthesupplyifaninsulationtestismade.
Thisproductiscoveredbyawarrantywhichextendsto5yearsfromthedateofmanufacture.
Precautions and Warranty
Ceiling Surface PIR occupancy switches
CESF PIR IP66
DANLERSceilingsurfacepassiveinfra-redoccupancyswitches(CESF
PIRIP66)canbeceilingmountedonthesquarepattressbox(PABO)
supplied.
TheCESFPIRIP66incorporatesapassiveinfra-redquadsensorto
detectmovementofawarmbodywithinitsdetectionzone(diagram
A)andaphotocelltomonitortheambientlightlevel.
Upondetectingmovement,iftheambientlightisdarkenough,the
CESFPIRIP66willswitchtheloadon.Theambientthresholdcan
besetbytheusertobetweenapproximately100luxandinnitelux
(photocellinactive)viatheLUXadjuster(diagramB).
Ifnomoremovementisdetectedwithinapre-selectedtime,thenthe
CESFPIRIP66willswitchtheloadoff.Thistimelagcanbesetvia
theTIMEadjusterto10seconds,20s,40s,1minute15seconds,
2m30s,5m,10m,20mor40minutes(diagramB).
CESF PIR IP66 also incorporates a sensitivity adjuster, labelled
‘SENS’,toreducetherangeandsensitivityofdetection(diagramB).
Loading
TheCESFPIRIP66canbeconnectedtoa230V(+/-10%)50Hz
(+/-10%)acsupply
Theycanswitchupto6amps(1500W)of:
• Fluorescentlamps,highfrequencyorswitchstart
• Incandescentormainshalogenlamps(recommendedwithintegralsafetyfuse)
• Electronicorwirewoundtransformers.
Theycanalsoswitchupto:
• 2amps(500W)oflowenergylamps:CFL,LED,2Detc.
• 1amp(250W)ofmetalhalidelampsorfans.
Theyhaveaminimumswitchingcapacityof0.5W,forlessthanthisaGold
relayversionshouldbeused,seeVariantssection.
Forlargerloads,thePIRcanbeusedtoswitchacontactor.
24/07/13 INSxxx CESF PIR IP66
Variants
AsDANLERSdesignandmanufactureintheUK,variantscanbesupplied,
codedbythefollowingsufxesandappliedinthisorder:
• 12Vor24V  12Vor24V(acordc)operation
• VF   VoltFreecontacts
• GOLDorLG GoldorLogicGoldcontacts
• NC   NormallyClosedcontacts
Variantdetailsarecoveredinanenclosedaddendumsheetifapplicable.
Troubleshooting
The load will not switch on:
• TheLUXadjusterissettoolowandisinhibitingtheswitch.
• TheSENSadjusterissettoolow.
• ThemovingbodyisnotemittingmoreIRthanthebackground.
  (Personwearinginsulatingclothinginawarmenvironment)
• PersonistoofarfromthePIRswitch,seedetectiondiagram.
• Personismovingunusuallyslowly(perhapswhentesting).
The load switches on when nobody is present:
• Heatercausinginfra-redvariationsinacoldsmallroomorceilingvoid
 drafts,fans,orsealeddoorscausingairmovement.
  Reducethesensitivityadjusterorconsiderusingthe
  CESFPIRIP662Ddoubledetectionversion.
• PleasecontactDANLERSforfurthertechnicalsupport.
Installation procedure
1.Pleasereadthesenotescarefullybeforecommencingwork.
Incaseofdoubtpleaseconsultaqualiedelectrician.
2.POSITIONING:TheCESFPIRIP66shouldbeinstalledtoachieve
correctcoverageofthearea,seediagramA.
Ifthephotocelloverride
facilityisrequired,theswitchmustbelocatedaboveanareawhere
daylightcangivegreaterilluminationthanthearticiallight.Avoid
locatingthisproductwhereitisexposedtowindyordraftyconditions
(exposed lobbies, open ceiling voids or near ventilation fans) or
nearheatsources.TocoverlargeareasCESFPIRIP66sshould
bespacedina5metregridformation.
3.ThegreatestenergysavingswillbemadeifeachCESFPIRIP66
controlsanindependentsetoflamps.Theycanbewiredinparallel
but this should ideally be limited to three, see diagram D.
4.Makesurethepowerisisolatedfromthecircuit.TheCESFPIR
IP66shouldbeconnectedasshownindiagramsC&D:
L-Livein.N-Neutralin.SL-SwitchedLineout.
Start-up mode
WhentheCESFPIRIP66ispoweredup,itwillswitchontheload
for1minute,theloadwillthenswitchoffandtheCESFPIRIP66will
enteritsOperatingMode.Ifamanualoverride-offswitchispositioned
beforetheCESFPIRIP66inthecircuit(diagramsC&D,note1)it
willdothiseachtimethewallswitchisswitchedon.Alternatively,if
thewallswitchisplacedafterthePIR(diagramsC&D,note2)itwill
not enter the start-up mode each time.
Time and Lux set-up
Forconvenience,ensurethattheTIMEissettotheminimumwhen
settinguptheLUXlevel.AfterwardssettheTIMEtoavaluesuitable
fortheapplication,makingreferencetodiagramB.
TheLUXisbestsetupwhenthelocalambientlightisatapproximately
theminimumdesiredworkinglightlevel,aluxmeterplacedonthesurface
undertheCESFPIRIP66mayhelp.WiththeLUXsetfullyclockwise
wait for the CESF PIR IP66 to switch off. Rotate the LUX adjuster
slowlyanticlockwise(-to+),whilstwavingyourhandapproximately
1mbelowthePIR,untiltheloadswitcheson.
L
load
Note 1: Optional
manual wall switch
for overriding off.
Note 2: Alternative
position for optional
wall switch
N
230 VAC
L
N
SL
up to 5m
up to 7m
Strong detection zone
i.e. person moving arm
or walking towards PIR
Secondary detection zone
i.e. person walking
perpendicular to PIR
For optimum coverage
recommended mounting
height: 2.4 to 5m
load
Note 1: Optional manual wall switch
for overriding off
Note 2: Alternative
position for optional
wall switch.
L
N
230 VAC
L
N
SL
L
N
SL
L
N
SL
A: Detection diagram
C: Wiring diagram,
single PIR
D: Wiring diagram, multiple PIRs
B: Adjusting time, lux
and sensitivity
TIME
min max
LUX
max min
SENS
min max
20s
40s
1m15s
2m30s
5m
10m
10s
20m
40m 100
∞
1000
66% 100%
Typical settings

Other DANLERS Switch manuals

DANLERS WACEPIR Quick start guide

DANLERS

DANLERS WACEPIR Quick start guide

DANLERS CEFLAPIR Quick start guide

DANLERS

DANLERS CEFLAPIR Quick start guide

DANLERS CEFLA PIR DSIP Quick start guide

DANLERS

DANLERS CEFLA PIR DSIP Quick start guide

DANLERS TLSW HB Quick start guide

DANLERS

DANLERS TLSW HB Quick start guide

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS GRTLA MK Quick start guide

DANLERS

DANLERS GRTLA MK Quick start guide

DANLERS CESRA PIR DSIP Quick start guide

DANLERS

DANLERS CESRA PIR DSIP Quick start guide

DANLERS WAPIR Quick start guide

DANLERS

DANLERS WAPIR Quick start guide

DANLERS CEPH NO Quick start guide

DANLERS

DANLERS CEPH NO Quick start guide

DANLERS EZ CESR Quick start guide

DANLERS

DANLERS EZ CESR Quick start guide

DANLERS CEFL PIR Quick start guide

DANLERS

DANLERS CEFL PIR Quick start guide

DANLERS TWSW Quick start guide

DANLERS

DANLERS TWSW Quick start guide

DANLERS CEFL PIR LR Quick start guide

DANLERS

DANLERS CEFL PIR LR Quick start guide

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS CESPLL10VDC Quick start guide

DANLERS

DANLERS CESPLL10VDC Quick start guide

DANLERS CESF PIR Quick start guide

DANLERS

DANLERS CESF PIR Quick start guide

DANLERS COPIR IP66 User manual

DANLERS

DANLERS COPIR IP66 User manual

DANLERS BMPIR10M Quick start guide

DANLERS

DANLERS BMPIR10M Quick start guide

DANLERS TLSW A20 Quick start guide

DANLERS

DANLERS TLSW A20 Quick start guide

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

DANLERS ControlZAPP CZ CEFL DALI Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL DALI Quick start guide

DANLERS ControlZAPP CZ CEFL 10VDC Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL 10VDC Quick start guide

DANLERS TLSW HB Quick start guide

DANLERS

DANLERS TLSW HB Quick start guide

Popular Switch manuals by other brands

SCHUNK MMS-P 22 Assembly and operating manual

SCHUNK

SCHUNK MMS-P 22 Assembly and operating manual

Vanco EVMX4444 manual

Vanco

Vanco EVMX4444 manual

Atlona AT-HDVS-200-TX-WP-BLK manual

Atlona

Atlona AT-HDVS-200-TX-WP-BLK manual

Digital Equipment DIGITAL MultiSwitch 612EX quick start

Digital Equipment

Digital Equipment DIGITAL MultiSwitch 612EX quick start

Eusso UGS5805-EMC Specifications

Eusso

Eusso UGS5805-EMC Specifications

D-Link DGS-8010 Quick installation guide

D-Link

D-Link DGS-8010 Quick installation guide

Sony SB-V60S operating instructions

Sony

Sony SB-V60S operating instructions

Cisco Nexus 9336C-FX2-E Hardware installation guide

Cisco

Cisco Nexus 9336C-FX2-E Hardware installation guide

Kramer VP-440H2 user manual

Kramer

Kramer VP-440H2 user manual

Lantronix SUN-PC Product guide

Lantronix

Lantronix SUN-PC Product guide

esera automation ESI 400 user guide

esera automation

esera automation ESI 400 user guide

Siemens 3KD16-2 Series operating instructions

Siemens

Siemens 3KD16-2 Series operating instructions

Huawei Quidway S3528 Series instruction manual

Huawei

Huawei Quidway S3528 Series instruction manual

Allied Telesis Rapier G6 Quick install guide

Allied Telesis

Allied Telesis Rapier G6 Quick install guide

HP 8/20q Installation and reference guide

HP

HP 8/20q Installation and reference guide

Acnodes KPH802 user manual

Acnodes

Acnodes KPH802 user manual

Popp Z-Wave quick start guide

Popp

Popp Z-Wave quick start guide

Enerwave WF500D Wi-Fi installation instructions

Enerwave

Enerwave WF500D Wi-Fi installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.