ThisproductconformstoBSEN60669-2-1.
Pleaseensurethemostrecenteditionoftheappropriatelocalwiringregulationsareobserved
andsuitableprotectionisprovidede.g.6ampsovercurrent,1kVovervoltage.Pleaseensure
thatthisdeviceisdisconnectedfromthesupplyifaninsulationtestismade.
Thisproductiscoveredbyawarrantywhichextendsto5yearsfromthedateofmanufacture.
Precautions and Warranty
Grid time lag switches (2-wire versions)
GRTL MK GRTL CB GRTL EU
GRTL MK ILM GRTL CB ILM GRTL EU ILM
DANLERSgridtimelagswitchesaresuitableforttingintotheMK
GridPlus(MK),Crabtreegrid(CB)andEurodataplates(EU).
Ashortpresswillswitchtheloadonanditwillswitchoffautomatically
afterthetimelagperiodhasexpired.Thetimelagcanbesetbetween
approximately 1 minute and 2 hours.
The button on the illuminated versions (ending ILM) is lit until the
buttonispressed,itcomesbackonwhenthetimelaghaselapsed.
Theloadcanbeswitchedonfromotherlocationsbyconnectingthese
devicesinparallelorbyconnectingDANLERSmatchingslaveswitches,
availableas:SSGSMK,SSGSCBandSSGSEU.
DANLERSgridtimelagswitchescanswitchupto6amps(1500W)of:
• Fluorescentlamps,eitherhighfrequencyorswitchstart
• Incandescentormainshalogenlamps(recommendedwithintegralsafetyfuse)
• Electronicorwirewoundtransformers.
Theycanalsoswitchupto:
• 1amp(250W)ofFansorMetalHalidelamps.
Thegridtimelagswitchesneedthefollowingdepthwallboxes:
• GRTLMK(ILM) 35mm(minimum)
• GRTLCB(ILM) 40mm(minimum)
• GRTLEU(ILM) 35mm(minimum)
12/02/14 INS911 GRTL
Loading
Time lag switch “clicks” off but load stays on:
• Non-resistiveload(contactor,emergency,CFL,LEDor2Dlamp)
AddCAPLOADacrosstheloadasshowninwiringdiagram.
• Faultdevelopedduetoanover-voltagespike.
Slave switch does not operate the time lag switch:
• EnsureonlyDANLERSslaveswitchesareused
• Ensureslavewiringislessthan10mlong.
Load latched either on or off:
• Faultdevelopedduetoonover-voltagespike.
Does not work with existing 2-way switches:
• Timelagsandslavescanusethewiringoftwoway(and
intermediate)systems,butcannotbemixedwithsuchsystems.