manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DANLERS
  6. •
  7. Switch
  8. •
  9. DANLERS CESF PIR Quick start guide

DANLERS CESF PIR Quick start guide

DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. products
Please call for more information or a free catalogue, or visit our website.
This product conforms to BS EN 60669-2-1.
Please ensure the most recent edition of the appropriate local wiring regulations are observed
and suitable protection is provided e.g. 6 amps over current, 1kV over voltage. Please ensure
that this device is disconnected from the supply if an insulation test is made.
This product is covered by a warranty which extends to 5 years from the date of manufacture.
Precautions and Warranty
Installation notes
Ceiling Surface PIR occupancy switches
CESF PIR
DANLERS ceiling surface passive infra-red occupancy switches (CESF
PIR) can be ceiling mounted on a square pattress box (DANLERS
code: PABO).
The CESF PIR incorporates a passive infra-red quad sensor to detect
movement of a warm body within its detection zone (diagram A) and
a photocell to monitor the ambient light level.
Upon detecting movement, if the ambient light is dark enough, the
CESF PIR will switch the load on. The ambient threshold can be set
by the user to between approximately 100 lux and innite lux (photocell
inactive) via the LUX adjuster (diagram B).
If no more movement is detected within a pre-selected time, then
the CESF PIR will switch the load off. This time lag can be set via
the TIME adjuster to 10 seconds, 20s, 40s, 1 minute 15 seconds,
2m 30s, 5m, 10m, 20m or 40 minutes (diagram B).
CESF PIR also incorporates a sensitivity adjuster, labelled ‘SENS’,
to reduce the range and sensitivity of detection (diagram B).
Loading
DANLERS CESF PIR units can switch up to 6 amps (1500W) of:
• Fluorescent lamps, high frequency or switch start
• Incandescent or mains halogen lamps (recommended with integral safety fuse)
• Electronic or wire wound transformers.
They can also switch up to:
• 1 amp (250W) of metal halide lamps or fans.
14/05/10 INS944 CESF PIR
Variants
As DANLERS design and manufacture in the UK, variants can be supplied,
coded by the following sufxes and applied in this order:
• 12V or 24V 12V or 24V (ac or dc) operation
• VF Volt Free contacts
• GOLD or LG Gold or Logic Gold contacts
• NC Normally Closed contacts
Variant details are covered in an enclosed addendum sheet if applicable.
Troubleshooting
The load will not switch on:
• The LUX adjuster is set too low and is inhibiting the switch.
• The SENS adjuster is set too low.
• The moving body is not emitting more IR than the background.
(Person wearing insulating clothing in a warm environment)
• Person is too far from the PIR switch, see detection diagram.
• Person is moving unusually slowly (perhaps when testing).
The load switches on when nobody is present:
• Heater causing infra-red variations in a cold small room or ceiling void
drafts, fans, or sealed doors causing air movement.
Reduce the sensitivity adjuster or consider using the CESF PIR 2D
double detection version.
• Please contact DANLERS for further technical support.
Installation procedure
1. Please read these notes carefully before commencing work.
In case of doubt please consult a qualied electrician.
2. POSITIONING: The CESF PIR should be installed to achieve correct
coverage of the area, see diagram A.
If the photocell override facility
is required, the switch must be located above an area where daylight
can give greater illumination than the articial light. Avoid locating this
product where it is exposed to windy or drafty conditions (exposed
lobbies, open ceiling voids or near ventilation fans) or near heat
sources. To cover large areas CESF PIRs should be spaced in a 5
metre grid formation.
3. The greatest energy savings will be made if each CESF PIR controls
an independent set of lamps. They can be wired in parallel but this
should ideally be limited to three, see diagram D.
4. Make sure the power is isolated from the circuit.
The CESF PIR should be connected as shown in diagrams C & D:
L - Live in. N - Neutral in. SL - Switched Line out.
Start-up mode
When the CESF PIR is powered up, it will switch on the load for 1
minute, the load will then switch off and the CESF PIR will enter its
Operating Mode. If a manual override-off switch is positioned before
the CESF PIR in the circuit (diagrams C & D, note 1) it will do this
each time the wall switch is switched on. Alternatively, if the wall switch
is placed after the PIR (diagrams C & D, note 2) it will not enter the
start-up mode each time.
Time and Lux set-up
For convenience, ensure that the TIME is set to the minimum when
setting up the LUX level. Afterwards set the TIME to a value suitable
for the application, making reference to diagram B.
The LUX is best set up when the local ambient light is at approximately
the minimum desired working light level, a lux meter placed on the
surface under the CESF PIR may help. With the LUX set fully clockwise
wait for the CESF PIR to switch off. Rotate the LUX adjuster slowly
anticlockwise (- to +), whilst waving your hand approximately 1m below
the PIR, until the load switches on.
L
load
Note 1: Optional
manual wall switch
for overriding off.
Note 2: Alternative
position for optional
wall switch
N
230 VAC
L
N
SL
TIME
min max
LUX
max min
SENS
min max
20s
40s
1m15s
2m30s
5m
10m
10s
20m
40m 100
∞
1000
66% 100%
Typical settings
up to 5m
up to 7m
Strong detection zone
i.e. person moving arm
or walking towards PIR
Secondary detection zone
i.e. person walking
perpendicular to PIR
For optimum coverage
recommended mounting
height: 2.4 to 5m
load
Note 1: Optional manual wall switch
for overriding off
Note 2: Alternative
position for optional
wall switch.
L
N
230 VAC
L
N
SL
L
N
SL
L
N
SL
A: Detection diagram
C: Wiring diagram,
single PIR
D: Wiring diagram, multiple PIRs
B: Adjusting time, lux
and sensitivity

Other manuals for CESF PIR

2

Other DANLERS Switch manuals

DANLERS BMEXPIR Quick start guide

DANLERS

DANLERS BMEXPIR Quick start guide

DANLERS ControlZAPP CZ CEFL DALI Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL DALI Quick start guide

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS CESF PIR IP66 Quick start guide

DANLERS

DANLERS CESF PIR IP66 Quick start guide

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS CEFLA PIR DALIP Quick start guide

DANLERS

DANLERS CEFLA PIR DALIP Quick start guide

DANLERS COPIR IP66 User manual

DANLERS

DANLERS COPIR IP66 User manual

DANLERS WAPIR Quick start guide

DANLERS

DANLERS WAPIR Quick start guide

DANLERS WACE RFS Quick start guide

DANLERS

DANLERS WACE RFS Quick start guide

DANLERS CEFLA PIR DSIP Quick start guide

DANLERS

DANLERS CEFLA PIR DSIP Quick start guide

DANLERS CZ HB ND Quick start guide

DANLERS

DANLERS CZ HB ND Quick start guide

DANLERS CESRA PIR DSIP Quick start guide

DANLERS

DANLERS CESRA PIR DSIP Quick start guide

DANLERS TLSW A20 Quick start guide

DANLERS

DANLERS TLSW A20 Quick start guide

DANLERS GRTLA MK User manual

DANLERS

DANLERS GRTLA MK User manual

DANLERS DUSW Quick start guide

DANLERS

DANLERS DUSW Quick start guide

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS CEFL PIR LR Quick start guide

DANLERS

DANLERS CEFL PIR LR Quick start guide

DANLERS TLSW HB Quick start guide

DANLERS

DANLERS TLSW HB Quick start guide

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS

DANLERS EasyZAPP EZ CEFL Quick start guide

DANLERS CESPLL10VDC Quick start guide

DANLERS

DANLERS CESPLL10VDC Quick start guide

DANLERS TWSW Quick start guide

DANLERS

DANLERS TWSW Quick start guide

DANLERS CESFPIRSV Quick start guide

DANLERS

DANLERS CESFPIRSV Quick start guide

DANLERS ControlZAPP CZ CEFL 10VDC Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL 10VDC Quick start guide

Popular Switch manuals by other brands

Avenview SW-VGA-5X5 user guide

Avenview

Avenview SW-VGA-5X5 user guide

Lucent Technologies Cajun P333T quick start guide

Lucent Technologies

Lucent Technologies Cajun P333T quick start guide

EtherWAN EX46910F installation guide

EtherWAN

EtherWAN EX46910F installation guide

Cisco SLM224G4PS user guide

Cisco

Cisco SLM224G4PS user guide

Jung FMAS816REG operating instructions

Jung

Jung FMAS816REG operating instructions

FS S5860-20SQ Configuration guide

FS

FS S5860-20SQ Configuration guide

Mackie SP-41R quick start guide

Mackie

Mackie SP-41R quick start guide

HP StorageWorks 1606 - Extension SAN Switch Quickspecs

HP

HP StorageWorks 1606 - Extension SAN Switch Quickspecs

HYDACELECTRONIC ENS 3000 user manual

HYDACELECTRONIC

HYDACELECTRONIC ENS 3000 user manual

Italtecnica PMA/12 quick start guide

Italtecnica

Italtecnica PMA/12 quick start guide

Lex PowerGATE LELTS-1 Series Installation instructions & user manual

Lex

Lex PowerGATE LELTS-1 Series Installation instructions & user manual

Omron D4NS - quick start guide

Omron

Omron D4NS - quick start guide

VONROC GP804AA Original instructions

VONROC

VONROC GP804AA Original instructions

NETGEAR ProSafe FS750T brochure

NETGEAR

NETGEAR ProSafe FS750T brochure

Multiplex 1-01784 instruction manual

Multiplex

Multiplex 1-01784 instruction manual

TRENDnet TL2-E284 Quick installation guide

TRENDnet

TRENDnet TL2-E284 Quick installation guide

IQlife Touch Wall Switch installation manual

IQlife

IQlife Touch Wall Switch installation manual

Key Digital Black Bull KD-HDRV2X1 operating instructions

Key Digital

Key Digital Black Bull KD-HDRV2X1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.